1.7 Parameters setting
PARAMETER
FUNCTION
MODE
p001
0par: when this parameter is stored, all parameters
will be set to default value and it will appear “rst” then
restart the driver
WS, MB, CO, PN, EC, EI, MT
p002
Step-Dir/Fieldbus
WS, MB, CO
p003
Current setting [A]
WS, MB, PN, EI, MT
p004
BaudRate
WS, MB, CO
p005
Address-ID
WS, MB, CO, EC
p006
Setting step resolution ( 1/2, ..., 1/20 )
WS, MB, PN, EI, MT
p007
Setting stand-by current ( 0, 25, 50, 100% )
WS, MB
p008
Setting parameter resonance1 reduction ( fd0...fd4 )
WS, MB
p009
Setting parameter resonance2 reduction ( small, big )
WS, MB
p010
Setting wave mode ( wav0, wav1 )
WS, MB
p011
Setting to operate high frequency
WS, MB
p013
Setting toggle bit ( 0 - 1 )
PN, EC, EI, MT
p014
Enable refresh for the last polled parameter
PN, EC, EI, MT
p015
FieldBus Type and Firmware Release
WS, MB, CO, PN, EC, EI, MT
By using the buttons below the display (hereinafter referred to as [\/] , [<>], [/\] ) you can parameterize the drive:
To access to main menù, press [\/] + [<>] , it will visualized “
menu
” for 1 sec, after the parameter “
p001
”
From the main menu to select the parameter to be changed press the button [\/] or [/\].
From main menù to visualize the actual value of parameter press [<>].
From the parameter to change the value press [\/] or [/\]
From the parameter to store the value press the button [<>] for 1 sec and it will appear “
memo
”
From the parameter to come back at main menù without modify any conditions, press [<>] less than 1 sec (don’t will
appear “
memo
”).
From the main menù to go out press [<>] + [/\].
8
WS = RS485 SHS Protocol
MB = Modbus
CO = CanOpen
PB = Profibus
PN
=
ProfiNet
EC = EtherCat
EI = Ethernet/IP
MT=Modbus/TCP
Содержание EtherCAT HT7
Страница 76: ...www shsitalia it info shsbox shsitalia it 15 ...
Страница 91: ...www shsitalia it info shsbox shsitalia it 2 5 Digital Inputs 2 6 Digital Outputs 14 ...
Страница 92: ...www shsitalia it info shsbox shsitalia it 2 7 Encoder Inputs 15 ...
Страница 95: ...www shsitalia it info shsbox shsitalia it 18 ...
Страница 110: ...www shsitalia it info shsbox shsitalia it 2 5 Digital Inputs 2 6 Digital Outputs 14 ...
Страница 111: ...www shsitalia it info shsbox shsitalia it 2 7 Encoder Inputs 15 ...
Страница 124: ...www shsitalia it info shsbox shsitalia it 28 ...
Страница 125: ...S H S s r l Via F lli Rosselli 29 20027 Rescaldina MI ITALY Tel 39 0331 466918 Fax 39 0331 466147 www shsitalia it ...