background image

 

  

 

 

   

 

Ordercode: 30781 

Stage Blinder 4 Blaze 

 

 

 

 

Return Procedure 

 

Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. 
Package must be clearly labeled with a Return Authorization Number (RMA number). Products returned 
without an RMA number will be refused. Highlite will not accept the returned goods or any responsibility. 
Call Highlite 0031-455667723 or mail 

[email protected]

 and request an RMA prior to shipping the 

fixture. Be prepared to provide the model number, serial number and a brief description of the cause for 
the return. Be sure to properly pack fixture, any shipping damage resulting from inadequate packaging is 
the customer’s responsibility. Highlite reserves the right to use its own discretion to repair or replace 
product(s). As a suggestion, proper UPS packing or double-boxing is always a safe method to use. 
 
Note: If you are given an RMA number, please include the following information on a piece of paper 
inside the box: 
01)

 

Your name 

02)

 

Your address 

03)

 

Your phone number 

04)

 

A brief description of the symptoms 

 

Claims 

The client has the obligation to check the delivered goods immediately upon delivery for any short-
comings and/or visible defects, or perform this check after our announcement that the goods are at their 
disposal. Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be 
reported to the carrier upon receipt of merchandise. 
It is the customer's responsibility to notify and submit claims with the shipper in the event that a fixture is 
damaged due to shipping. Transportation damage has to be reported to us within one day after receipt 
of the delivery. 
Any return shipment has to be made post-paid at all times. Return shipments must be accompanied with 
a letter defining the reason for return shipment. Non-prepaid return shipments will be refused, unless 
otherwise agreed in writing. 
Complaints against us must be made known in writing or by fax within 10 working days after receipt of the 
invoice. After this period complaints will not be handled anymore. 
Complaints will only then be considered if the client has so far complied with all parts of the agreement, 
regardless of the agreement of which the obligation is resulting. 
 

 

Содержание Stage Blinder 4 Blaze

Страница 1: ...Stage Blinder 4 Blaze V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 30781 MANUAL ENGLISH...

Страница 2: ...ontrol 10 Fixture Linking 11 Data Cabling 11 Control Panel 12 Control Mode 12 DMX Addressing 12 Menu Overview 13 Main Menu Options 15 1 DMX Address DMX Configuration 15 2 Manual Color mode 16 3 Haloge...

Страница 3: ...erating temperatures than in ideal or singular optimum conditions For this reason when all color LEDs are used at their fullest intensity life of the LEDs is significantly reduced If improving your li...

Страница 4: ...e operating Always allow a free air space of at least 80 cm around the unit for ventilation Always disconnect power from the mains when device is not used or before cleaning Only handle the power cord...

Страница 5: ...warranty becomes void Any other operation may lead to dangers like short circuit burns electric shock crash etc You endanger your own safety and the safety of others Rigging Please follow the European...

Страница 6: ...the mains Connect the device to the mains with the power plug Always pay attention that the right color cable is connected to the right place International EU Cable UK Cable US Cable Pin L BROWN RED Y...

Страница 7: ...one number 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform th...

Страница 8: ...3200K Output 18500lm Pod movement 20 stepless Beam angle 39 Field angle 78 Dimmer 0 100 Strobe 0 20Hz IP rating IP65 Housing Black powder coated metal DMX control via standard DMX controller Onboard O...

Страница 9: ...lastic padding is removed Connect all cables Do not supply power before the whole system is set up and connected properly Always disconnect from electric mains power supply before cleaning or servicin...

Страница 10: ...Slave control 01 Fasten the effect light onto firm trussing Leave at least 0 5 meter on all sides for air circulation 02 Always use a safety cable ordercode 70140 70141 03 Plug the end of the electric...

Страница 11: ...vices 05 Link the units as shown in fig 04 Connect a DMX signal cable from the first unit s DMX out socket to the second unit s in socket Repeat this process to link the second third and fourth units...

Страница 12: ...can carry a high quality signal and are less prone to electromagnetic interference DAP Audio DMX Data Cables DAP Audio Basic microphone cable for allround use bal XLR M 3 pin XLR F 3 pin Ordercode FL...

Страница 13: ...uld be 1 16 17 017 the DMX address of the third Stage Blinder should be 17 16 33 033 etc Please be sure that you do not have any overlapping channels in order to control each Stage Blinder correctly I...

Страница 14: ...13 Ordercode 30781 Stage Blinder 4 Blaze Menu Overview...

Страница 15: ...14 Ordercode 30781 Stage Blinder 4 Blaze...

Страница 16: ...u can set the device s DMX starting address and choose a DMX channel mode 01 While in the main menu press the UP DOWN buttons to choose DMX 02 Press the SET button to open the menu 03 Press the UP DOW...

Страница 17: ...djust the color intensity 05 Press the UP DOWN buttons to set the color intensity The adjustment range is between 0 255 from dark to brightest 3 Halogen With this menu you can set the halogen function...

Страница 18: ...e auto program 05 If you have chosen NO the device will keep its current settings 5 Program With this menu you can set the preset colors or the program speed and the strobe frequency of the built in p...

Страница 19: ...s to choose one of the 2 options SPEED STROBE 03 Press the SET button to enter the desired menu 04 If you have chosen SPEED press the UP DOWN buttons to set the built in program s speed The adjustment...

Страница 20: ...e menu 03 Press the UP DOWN buttons to toggle through the following menus CURVES SELECT DIMMER SPEED DMX FAIL DMX SYNC LOCK KEY BACKLIGHT and FACTORY 04 Press the SET button to open the menu 7 1 Curve...

Страница 21: ...will black out the light output HOLD the device will use last properly received DMX signal ensuring undisrupted performance MANUAL the device will switch to Manual mode PROGRAM the device will run th...

Страница 22: ...acklight With this menu you can set whether the 4 buttons MODE SET UP DOWN will be illuminated or not 01 Press the UP DOWN buttons to select ON or OFF 02 Press the SET button to confirm your choice 7...

Страница 23: ...m dark to brightest 13 Channels Channel 1 White dimmer intensity POD 1 0 255 Gradual adjustment White from dark to brightest Channel 2 Amber dimmer intensity POD 1 0 255 Gradual adjustment Amber from...

Страница 24: ...00 119 136 Color 7 R255 G000 B255 137 154 Color 8 R255 G000 B140 155 172 Color 9 R000 G255 B255 173 190 Color 10 R255 G100 B100 191 208 Color 11 R100 G255 B100 209 226 Color 12 R100 G255 B100 227 244...

Страница 25: ...tment Blue from dark to brightest Channel 8 Red dimmer intensity POD 2 0 255 Gradual adjustment Red from dark to brightest Channel 9 Green dimmer intensity POD 2 0 255 Gradual adjustment Green from da...

Страница 26: ...esidues reducing the light output very quickly Keep connections clean Disconnect electric power and then wipe the DMX connections with a damp cloth Make sure connections are thoroughly dry before link...

Страница 27: ...d data link connection Inspect connections and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120 Ohm termination plug Insert termination plug in output...

Страница 28: ...m Refresh rate 4000Hz Pod movement 20 stepless Beam angle 39 Field angle 78 IP rating IP65 Housing Black powder coated metal DMX control Via standard DMX controller Onboard OLED display for easy setup...

Страница 29: ...28 Ordercode 30781 Stage Blinder 4 Blaze Dimensions...

Страница 30: ...29 Ordercode 30781 Stage Blinder 4 Blaze Notes...

Страница 31: ...30 Ordercode 30781 Stage Blinder 4 Blaze...

Страница 32: ...2018 Showtec...

Отзывы: