9
Ordercode: 30781
Stage Blinder 4 Blaze
Control Modes
There are 6 modes:
●
Auto
●
Built-in programs
●
Manual
●
Halogen
●
Master/Slave
●
DMX-512 (1CH, 4CH, 13CH, 16CH)
One Stage Blinder (Auto, Built-in programs, Manual and Halogen)
01)
Fasten the effect light onto firm trussing. Leave at least 0,5 meter on all sides for air circulation.
02)
Always use a safety cable (ordercode 70140 / 70141).
03)
Plug the end of the electric mains power cord into a proper electric power supply socket.
04)
When the Stage Blinder is not connected with a DMX cable, it functions as a stand-alone device.
Please see pages 16-18 for more information about Auto, Built-in programs, Manual and Halogen.
Multiple Stage Blinders (Master/Slave control)
01)
Fasten the effect light onto firm trussing. Leave at least 0,5 meter on all sides for air circulation.
02)
Always use a safety cable (ordercode 70140 / 70141).
03)
Plug the end of the electric mains power cord into a proper electric power supply socket.
04)
Use a 3-pin XLR cable to connect the Stage Blinder and other devices.
The pins:
1.
Earth
2.
Signal (-)
3.
Signal (+)
05)
Link the units as shown in fig. 03. Connect a DMX signal cable from the first unit's DMX "out" socket to
the second unit's "in" socket. Repeat this process to link the second, third and fourth units. You can
use the same functions on the master device as described on pages 16-18 (Auto, Built-in programs,
Manual and Halogen). This means that you can set your desired operation mode on the master
device and all slave devices will react the same as the master device.
Multiple Stage Blinders (
Master/Slave control)
Fig. 03
Содержание Stage Blinder 4 Blaze
Страница 14: ...13 Ordercode 30781 Stage Blinder 4 Blaze Menu Overview...
Страница 15: ...14 Ordercode 30781 Stage Blinder 4 Blaze...
Страница 29: ...28 Ordercode 30781 Stage Blinder 4 Blaze Dimensions...
Страница 30: ...29 Ordercode 30781 Stage Blinder 4 Blaze Notes...
Страница 31: ...30 Ordercode 30781 Stage Blinder 4 Blaze...
Страница 32: ...2018 Showtec...