background image

 

  

 

 

   

 

Ordercode: 40051 

 

Phantom 70 Beam RGBW 

IMPORTANT: 

The manufacturer will not accept liability for any resulting damages caused by the non-observance of 
this manual or any unauthorized modification to the device. 
 

 

Never let the power cord come into contact with other cables! Handle the power cord and all 
connections with the mains with particular caution! 

 

Never remove warning or informative labels from the unit. 

 

Never use anything to cover the ground contact. 

 

Never lift the fixture by holding it at the projector-head, as the mechanics may be damaged. 

 

Never place any material over the lens. 

 

Never look directly into the light source. 

 

Never leave any cables lying around. 

 

Do not insert objects into air vents. 

 

Do not connect this device to a dimmerpack. 

 

Do not switch the device on and off in short intervals, as this would reduce the device’s life. 

 

Do not touch the device’s housing bare-handed during its operation. Allow the fixture to cool for at 
least 5 minutes before handling. 

 

Do not shake the device. Avoid brute force when installing or operating the device. 

 

Only use device indoor, avoid contact with water or other liquids. 

 

Only operate the fixture after having checked that the housing is firmly closed and all screws are 
tightly fastened. 

 

Only operate the device after having familiarized with its functions. 

 

Avoid flames and do not put close to flammable liquids or gases. 

 

Always keep case closed while operating. 

 

Always allow free air space of at least 50 cm around the unit for ventilation. 

 

Always disconnect power from the mains, when device is not used or before cleaning! Only handle 
the power cord by the plug. Never pull out the plug by tugging the power cord. 

 

Make sure that the device is not exposed to extreme heat, moisture or dust. 

 

Make sure that the available voltage is not higher than stated on the rear panel. 

 

Make sure that the power cord is never crimped or damaged. Check the device and the power 
cord from time to time. 

 

If the lens is obviously damaged, it has to be replaced. So that its functions are not impaired, due to 
cracks or deep scratches. 

 

If device is dropped or struck, disconnect mains power supply immediately. Have a qualified 
engineer inspect for safety before operating. 

 

If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not 
switch it on immediately. The arising condensation water might damage your device. Leave the 
device switched off until it has reached room temperature. 

 

If your Showtec device fails to work properly, discontinue use immediately. Pack the unit securely 
(preferably in the original packing material), and return it to your Showtec dealer for service. 

 

For adult use only. Device must be installed out of the reach of children. Never leave the unit running 
unattended. 

 

Never attempt to bypass the thermostatic switch or fuses. 

 

For replacement use fuses of same type and rating only. 

 

The user is responsible for correct positioning and operating of the Phantom 70 Beam RGBW. The 
manufacturer will not accept liability for damages caused by the misuse or incorrect installation of 
this device. 

 

This device falls under protection class I. Therefore it is essential to connect the yellow/green 
conductor to earth. 

 

During the initial start-up some smoke or smell may arise. This is a normal process and does not 
necessarily mean that the device is defective. 

 

Repairs, servicing and electric connection must be carried out by a qualified technician. 

 

WARRANTY: Till one year after date of purchase. 

 

 

Содержание Phantom 70 Beam RGBW

Страница 1: ...Phantom 70 Beam RGBW V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 40051 MANUAL ENGLISH...

Страница 2: ...m Beams Master Slave Control 11 Multiple Phantom Beams DMX Control 12 Fixture Linking 13 Data Cabling 13 Control Panel 14 DMX Control Mode 14 DMX Addressing 14 Menu Overview 15 Main Menu Options 16 1...

Страница 3: ...2 Ordercode 40051 Phantom 70 Beam RGBW Troubleshooting 28 No Light 28 No Response to DMX 29 Product Specifications 30 Dimensions 31 Notes 32...

Страница 4: ...sters LEDs exhibit higher operating temperatures than in ideal or singular optimum conditions For this reason when all color LEDs are used at their fullest intensity life of the LEDs is significantly...

Страница 5: ...e plug by tugging the power cord Make sure that the device is not exposed to extreme heat moisture or dust Make sure that the available voltage is not higher than stated on the rear panel Make sure th...

Страница 6: ...r own safety and the safety of others Rigging Please follow the European and national guidelines concerning rigging trussing and all other safety issues Do not attempt the installation yourself Always...

Страница 7: ...erty Connection with the mains Connect the device to the mains with the power plug Always pay attention that the right color cable is connected to the right place International EU Cable UK Cable US Ca...

Страница 8: ...ne number 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform thi...

Страница 9: ...s are selectable by DMX Special Pan Tilt reverse Black out by DMX DMX Modes 8 12 16 Channels DMX control via standard DMX controller Beam angle 5 60mm 5 Optics Dimmer 0 100 electronic dimmer Compact P...

Страница 10: ...9 Ordercode 40051 Phantom 70 Beam RGBW Frontside Fig 02 01 7 X 10W RGBW 4 in 1 LEDs 02 Control LEDs 03 LCD Display 04 MENU control NOTE Knowledge of DMX is required to fully utilize this unit...

Страница 11: ...stic padding is removed Connect all cables Do not supply power before the whole system is set up and connected properly Always disconnect from electric mains power supply before cleaning or servicing...

Страница 12: ...y socket 03 Turn on the music If the device is set to sound control then the Phantom 70 Beam will react to the beat of the music Please see page 18 for more information about the sound control options...

Страница 13: ...e Phantom Beam RGBW and other devices 05 Link the units as shown in Fig 05 Connect a DMX signal cable from the first unit s DMX out socket to the second unit s in socket Repeat this process to link th...

Страница 14: ...io certified DMX cables directly from a dealer distributor or construct your own cable If you choose to create your own cable please use data grade cables that can carry a high quality signal and are...

Страница 15: ...Beam RGBW should be 17 16 33 033 etc Please be sure that you do not have any overlapping channels in order to control each Phantom Beam RGBW correctly If two or more Phantom Beams are addressed simila...

Страница 16: ...15 Ordercode 40051 Phantom 70 Beam RGBW Menu Overview...

Страница 17: ...l Mode 3 Run Mode 4 Functions 5 Version 1 DMX 512 01 While in main menu turn the MENU control 03 until the display shows 02 Press the MENU control 03 to enter the menu 03 The display will show the fol...

Страница 18: ...and their functions see page 22 3 Run Mode 01 While in main menu turn the MENU control 03 until the display shows 02 Press the MENU control 03 to enter the menu 03 Turn the MENU control 03 to toggle...

Страница 19: ...and press the MENU control 03 to enter the menu 02 The display will show the following screen 03 Turn the MENU control 03 to adjust the sound sensitivity of the device The adjustment range is between...

Страница 20: ...to enter the menu 02 Turn the MENU control 03 choose Normal and press the MENU control 03 to deactivate pan inversion 03 Turn the MENU control 03 choose Invert and press the MENU control 03 to activa...

Страница 21: ...e between the 4 available modes Off DMX signal lost device stops Hold DMX signal lost device will memorize the last successfully received DMX signal and will continue using it until DMX signal recepti...

Страница 22: ...ntrol 03 choose No and press the MENU control 03 to cancel the reset function 06 Press the MENU control 03 to confirm the changes 4 8 Factory Sets 01 Press the MENU control 03 to enter the menu 02 Tur...

Страница 23: ...or Macro 0 7 No function 8 13 Color1 R255 G000 B000 W000 14 20 Color2 R255 G000 B000 W100 21 27 Color3 R255 G000 B000 W200 28 34 Color4 R255 G050 B000 W000 35 41 Color5 R255 G150 B000 W000 42 48 Color...

Страница 24: ...6 10 Show1 11 20 Show2 21 30 Show3 31 40 Show4 41 50 Show5 51 60 Show6 61 70 Show7 71 80 Show8 81 90 Slave1 91 96 Slave2 97 160 Sound sensitivity from low sensitivity to high sensitivity 161 170 Pan...

Страница 25: ...4 Tilt fine 16 bit Channel 5 Pan Tilt speed 0 255 From Max Speed 0 to Min Speed 255 Channel 6 Dimmer 0 255 From dark to brightest Channel 7 Linear Strobe 0 10 Off 11 255 Strobe intensity from slow to...

Страница 26: ...55 From dark to brightest Channel 7 Linear Strobe 0 10 Off 11 255 Strobe intensity from slow to fast Channel 8 Random Strobe 0 10 Off 11 255 Strobe intensity from slow to fast Channel 9 Color Macro CH...

Страница 27: ...or Jump2 48 63 Color Jump3 64 79 Color Jump4 80 95 Color Jump5 96 111 Color Jump6 112 127 Color Jump7 128 143 Color Jump8 144 159 Color Fade1 160 175 Color Fade2 176 191 Color Fade3 192 207 Color Fade...

Страница 28: ...ity 0 255 Gradual adjustment Red from 0 100 Channel 14 Green color intensity 0 255 Gradual adjustment Green from 0 100 Channel 15 Blue color intensity 0 255 Gradual adjustment Blue from 0 100 Channel...

Страница 29: ...races of wearing 04 The electric power supply cables must not show any damages or material fatigue Replacing the Fuse Power surges short circuit or inappropriate electrical power supply may cause a fu...

Страница 30: ...the problem may be a bad data link connection poor quality or broken cables missing termination plug or a defective fixture disturbing the link Bad data link connection Inspect connections and cables...

Страница 31: ...ard DMX controller On Board LCD display for easy setup Control Auto Manual Sound controlled Master Slave DMX512 Housing Black Metal Flame retardant plastic Connections Blue Pro Power connector IN and...

Страница 32: ...31 Ordercode 40051 Phantom 70 Beam RGBW Dimensions...

Страница 33: ...32 Ordercode 40051 Phantom 70 Beam RGBW Notes...

Страница 34: ...33 Ordercode 40051 Phantom 70 Beam RGBW...

Страница 35: ...34 Ordercode 40051 Phantom 70 Beam RGBW...

Страница 36: ...2016 Showtec...

Отзывы: