14
Ordercode: 40051
Phantom 70 Beam RGBW
Control Panel
Press and turn the control to navigate
through the menu options
Fig. 06
DMX Control Mode
The fixtures are individually addressed on a data-link and connected to the controller. When a DMX
signal is present, the DMX LED will blink.
The fixtures respond to the DMX signal from the controller. (When you select the DMX address and save it,
the controller will display the saved DMX address the next time.)
DMX Addressing
The control panel on the front side of the base allows you to assign the DMX fixture address, which is the
first channel from which the Phantom 70 Beam RGBW will respond to the controller.
Please note when you use the controller, the unit has
16
channels.
When using multiple Phantom Beams make sure you set the DMX addresses right.
Therefore, the DMX address of the first Phantom Beam RGBW should be
1(001)
; the DMX address of the
second Phantom Beam RGBW should be
1+16=17 (017
); the DMX address of the third Phantom Beam
RGBW should be
17+16=33 (033)
, etc.
Please, be sure that you do not have any overlapping channels in order to control each Phantom Beam
RGBW correctly.
If two or more Phantom Beams are addressed similarly, they will work similarly.
Controlling:
After having addressed all Phantom Beam RGBW fixtures, you may now start operating these via your
lighting controller.
Note:
After switching on, the Phantom Beam RGBW will automatically detect whether DMX 512 data is
received or not. If there is no data received at the DMX-input, the DMX LED will not blink.
The problem may be:
The XLR cable from the controller is not connected with the input of the Phantom Beam RGBW.
The controller is switched off or defective, the cable or connector is detective, or the signal wires are
swapped in the input connector.
Note:
It is necessary to insert an XLR termination plug (with 120 Ohm) in the last fixture in order to ensure
proper transmission on the DMX data link.
Display Off after 10 seconds
When no button is pressed for 10 seconds, the display will turn off.
To light up the display, you have to press or turn the MENU control
(03)
.
Once you have pressed or turned the control, the display will light up.
Содержание Phantom 70 Beam RGBW
Страница 16: ...15 Ordercode 40051 Phantom 70 Beam RGBW Menu Overview...
Страница 32: ...31 Ordercode 40051 Phantom 70 Beam RGBW Dimensions...
Страница 33: ...32 Ordercode 40051 Phantom 70 Beam RGBW Notes...
Страница 34: ...33 Ordercode 40051 Phantom 70 Beam RGBW...
Страница 35: ...34 Ordercode 40051 Phantom 70 Beam RGBW...
Страница 36: ...2016 Showtec...