background image

 

  

 

 

   

 

Ordercode: 33060 

Performer Profile 600 

Before the initial start-up, please make sure that there is no damage caused by transportation.  
Should there be any, consult your dealer and do not use the device. 
 
To maintain perfect condition and to ensure a safe operation, it is absolutely necessary for the user to 
follow the safety instructions and warning notes contained in this manual. 
 
Please consider that damages caused by manual modifications to the device are not subject to 
warranty. 
 
This device contains no user-serviceable parts. Refer servicing to qualified technicians only. 
 

IMPORTANT: 

The manufacturer will not accept liability for any resulting damages caused by the non-observance of 
this manual or any unauthorized modification to the device.

 

 

 

Never let the power cord come into contact with other cables! Handle the power cord and all 
connections with the mains with particular caution! 

 

Never remove warning or informative labels from the unit. 

 

Never use anything to cover the ground contact. 

 

Never lift the fixture holding it by the projector-head, as the mechanics may be damaged. Always 
hold the fixture by the transport handles. 

 

Never place any material over the lens. 

 

Never look directly into the light source. 

 

Never leave any cables lying around. 

 

Never loosen the screws of the rotating gobo otherwise you risk opening of the ball bearing. 

 

Do not insert objects into air vents. 

 

Do not connect this device to a dimmerpack. 

 

Do not switch the device on and off in short intervals, as this will reduce the device’s life. 

 

Do not touch the device’s housing bare-handed during its operation (housing becomes very hot). 
Allow the fixture to cool for at least 5 minutes before handling. 

 

Do not shake the device. Avoid brute force when installing or operating the device. 

 

Only use the device indoors, avoid contact with water or other liquids. 

 

Only operate the fixture after having checked if the housing is firmly closed and all screws are tightly 
fastened. 

 

Only operate the device after having familiarized with its functions. 

 

Avoid flames and do not put close to flammable liquids or gases. 

 

Always keep the case closed while operating. 

 

Always allow a free air space of at least 50 cm around the unit for ventilation. 

 

Always disconnect power from the mains, when device is not used or before cleaning! Only handle 
the power cord holding it by the plug. Never pull out the plug by tugging the power cord. 

 

Make sure that the device is not exposed to extreme heat, moisture or dust. 

 

Make sure that the available voltage is not higher than stated on the rear panel. 

 

Make sure that the power cord is never crimped or damaged. Check the device and the power 
cord from time to time. 

 

If the lens is obviously damaged, it has to be replaced. 

 

If device was dropped or struck, disconnect mains power supply immediately. Have a qualified 
engineer inspect for safety before operating. 

 

If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not 
switch it on immediately. The arising condensation water might damage your device. Leave the 
device switched off until it has reached room temperature. 

 

If your Showtec device fails to work properly, discontinue the use immediately. Pack the unit securely 
(preferably in the original packing material), and return it to your Showtec dealer for service. 

 

For adult use only. Moving head must be installed beyond the reach of children. Never leave the unit 
running unattended. 

 

Never attempt to bypass the thermostatic switch or fuses. 

 

For replacement use fuses of same type and rating only. 

 

 

Содержание Performer Profile 600

Страница 1: ...Performer Profile 600 V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 33060 MANUAL ENGLISH...

Страница 2: ...e barrel assembly 14 Installation with clamp 14 Setting the angle 15 Control Modes 16 One Performer Run Mode 16 Multiple Performers Master Slave control 16 Multiple Performers DMX Control 17 Fixture L...

Страница 3: ...rofile 600 Cleaning 25 Cleaning 19 26 36 and 50 glass lenses 25 Cleaning the reflector 25 Maintenance 26 Replacing the Fuse 26 Troubleshooting 26 No Light 26 No Response to DMX 27 Product Specificatio...

Страница 4: ...ludes Showtec Performer Profile 600 2 color frames 2 safety cables User manual LED Expected Lifespan LEDs gradually decline in brightness over time HEAT is the dominant factor that leads to the accele...

Страница 5: ...before handling Do not shake the device Avoid brute force when installing or operating the device Only use the device indoors avoid contact with water or other liquids Only operate the fixture after h...

Страница 6: ...y must not exceed 50 with an ambient temperature of 40 C If this device is operated in any other way than the one described in this manual the product may suffer damages and the warranty becomes void...

Страница 7: ...ight color cable is connected to the right place International EU Cable UK Cable US Cable Pin L BROWN RED YELLOW COPPER PHASE N BLUE BLACK SILVER NEUTRAL YELLOW GREEN GREEN GREEN PROTECTIVE GROUND Mak...

Страница 8: ...number 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this...

Страница 9: ...smooth fades Strobe 0 20Hz Beam Angle 26 Connections 3 and 5 pin XLR signal connectors IN OUT Powercon power connectors IN OUT Refresh Rate 1200Hz Power Linking 4 units 120V 7 units 230V DMX channels...

Страница 10: ...rol 03 Barrel 04 Mounting bracket 05 LED lens 06 LED board 07 Thermal switch holder thermal switch 08 Driver board 09 Insulated handle 10 PCB 11 Fuse T3 15AL 250V 12 PS socket 13 PS socket 14 PCB adap...

Страница 11: ...se T3 15AL 250V 21 Powercon power connector 100 240V IN 22 Powercon power connector 100 240V OUT 23 5 pin DMX signal connector IN 24 5 pin DMX signal connector OUT 25 3 pin DMX signal connector IN 26...

Страница 12: ...ugging the unit in always make sure that the power supply matches the product specification voltage Do not attempt to operate a 120V specification product on 230V power or vice versa Connect the devic...

Страница 13: ...rt the color frame s 03 Lock the retaining clip by pushing sideways while gently pushing forward Fig 06 Color Notes The performance of saturated colors is not guaranteed with low temperature ranges Fo...

Страница 14: ...cured with 2 screws prevents light leakage Fig 08 01 Use a screwdriver to loosen the screws on the drop in iris slot cover Do not remove the screws 02 Slide the cover completely forward to expose the...

Страница 15: ...control to lock it into position Fig 09 Installation with clamp You can choose an appropriate clamp from your dealer to fix the fixture to a trussing system and allows you to adjust the position of t...

Страница 16: ...0 Performer Profile 600 Setting the angle 01 Loosen the adjustment screws do not remove them 02 Tilt the fixture to the desired position Fig 11 03 Tighten the adjustment screws to secure the fixture i...

Страница 17: ...iple Performers Master Slave control 01 Fasten the effect light onto firm trussing Leave at least 0 5 meter on all sides for air circulation 02 Use a 3 pin XLR cable to connect the Performer The pins...

Страница 18: ...Connect the first unit s DMX out socket with the second unit s in socket using a DMX signal cable Repeat this process to link the second third and fourth units 05 Supply electric power Plug electric...

Страница 19: ...ures on a Powercon link 7 units 230V Data Cabling To link fixtures together you must obtain data cables You can purchase DAP Audio certified DMX cables directly from a dealer distributor or construct...

Страница 20: ...ss of the third Performer should be 4 3 7 007 etc Please be sure that you do not have any overlapping channels in order to control each Performer correctly If two or more Performers are addressed simi...

Страница 21: ...20 Ordercode 33060 Performer Profile 600 Menu Overview...

Страница 22: ...e ENTER button to open the menu 03 If the display shows you need to insert a key combination which will unlock the menu 04 Insert the key combination by pressing the buttons in the following order UP...

Страница 23: ...ollowing order UP DOWN UP DOWN ENTER 03 The display will promptly show and the settings will have been reset 2 4 Save DMX Blackout 01 When the display shows press the ENTER button to open the menu 02...

Страница 24: ...r level 2 8 Dimming curve settings 01 When the display shows press the ENTER button to open the menu 02 Press the UP and DOWN buttons to choose the desired dimming curve out of the 4 available options...

Страница 25: ...tilize the DMX protocol to determine its performance 05 If the display shows the Performer will become a slave device and will react the same as the master device DMX Channels 1 Channel Channel 1 Dimm...

Страница 26: ...e before attempting to clean the reflector To quickly clean the reflector remove the lens tube and clean the dust from the reflector with a blast of oil free air You may also wipe the reflector with a...

Страница 27: ...damp cloth Make sure connections are thoroughly dry before linking equipment or supplying electric power Replacing the Fuse Power surges short circuit or inappropriate electrical power supply may cau...

Страница 28: ...the problem may be a bad data link connection poor quality or broken cables missing termination plug or a defective fixture disturbing the link Bad data link connection Inspect connections and cables...

Страница 29: ...anual Beam Angle 26 Dimmer 0 100 Dim Curve Dimm4 technology 4 presets Strobe 0 20Hz Peak Intensity 71900cd Max Flux 3800 Lumen Color Rendering 83Ra Color Temperature 3100K Refresh Rate 1200Hz Housing...

Страница 30: ...29 Ordercode 33060 Performer Profile 600 Dimensions...

Страница 31: ...30 Ordercode 33060 Performer Profile 600 Notes...

Страница 32: ...2015 Showtec...

Отзывы: