background image

 

IMPORTANT:

 

The manufacturer will not accept liability for any resulting damages caused by the non-
observance of this manual or any unauthorized modification to the device. 

 

 

Never let the power-cord come into contact with other cables! Handle the power-cord and all 
connections with the mains with particular caution! 

 

Never remove warning or informative labels from the unit. 

 

Never use anything to cover the ground contact. 

 

Never leave any cables lying around. 

 

Do not insert objects into air vents. 

 

Do not connect this device to a dimmerpack. 

 

Do not open the device and do not modify the device. 

 

Never use the device during thunderstorms, unplug the device immediately. 

 

Never look directly into the light source. 

 

Do not switch the device on and off in short intervals, as this would reduce the system’s life. 

 

Do not shake the device. Avoid brute force when installing or operating the device. 

 

Only use device indoor, avoid contact with water or other liquids. 

 

Only operate the fixture after having checked that the housing is firmly closed and all screws are 
tightly fastened. 

 

Avoid flames and do not put close to flammable liquids or gases. 

 

Always allow free air space of at least 50 cm around the unit for ventilation. 

 

Always disconnect power from the mains, when device is not used or before cleaning! Only 
handle the power-cord by the plug. Never pull out the plug by tugging the power-cord. 

 

Make sure that the device is not exposed to extreme heat, moisture or dust. 

 

Make sure that the available voltage is not higher than stated on the rear panel. 

 

Make sure that the power-cord is never crimped or damaged. Check the device and the power-
cord from time to time. 

 

If the external cable is damaged, it has to be replaced by a qualified technician. 

 

If the lens is obviously damaged, it has to be replaced. So that its functions are not impaired, due 
to cracks or deep scratches. 

 

If device is dropped or struck, disconnect mains power supply immediately. Have a qualified 
engineer inspect for safety before operating. 

 

If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do 
not switch it on immediately. The arising condensation water might damage your device. Leave 
the device switched off until it has reached room temperature. 

 

If your Showtec device fails to work properly, discontinue use immediately. Pack the unit securely 
(preferably in the original packing material), and return it to your Showtec dealer for service. 

 

For adult use only. Light effect must be installed out of the reach of children. Never leave the unit 
running unattended. 

 

For replacement use fuses of same type and rating only. 

 

The user is responsible for correct positioning and operating of the Compact Par 18 Tri MKII. The 
manufacturer will not accept liability for damages caused by the misuse or incorrect installation 
of this device. 

 

This device falls under protection class I. Therefore it is essential to connect the yellow/green 
conductor to earth. 

 

During the initial start-up some smoke or smell may arise. This is a normal process and does not 
necessarily mean that the device is defective. 

 

Repairs, servicing and electric connection must be carried out by a qualified technician. 

 

WARRANTY: Till one year after date of purchase. 

 
 
 
 
 
 
 
 

 

 

CAUTION ! EYEDAMAGES !. 

Avoid looking directly into the light source. 

(meant especially for epileptics) !

 

 

Содержание Cameleon Spot 18-3

Страница 1: ...Compact Par 18 Tri MKII ORDERCODE 42592...

Страница 2: ...design and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep you our customer satisfied For more information iwant...

Страница 3: ...One Compact Par Sound control 8 Multiple Compact Pars Master Slave control 8 Multiple Compact Pars DMX Control 9 Fixture Linking 9 Data Cabling 9 Control Panel 10 DMX Control Mode 10 DMX Addressing 1...

Страница 4: ...ns If improving on this lifespan expectancy is of a higher priority place care in providing for lower operational temperatures This may include climatic environmental and the reduction of overall proj...

Страница 5: ...power cord is never crimped or damaged Check the device and the power cord from time to time If the external cable is damaged it has to be replaced by a qualified technician If the lens is obviously d...

Страница 6: ...the installation yourself Always let the installation be carried out by an authorized dealer Procedure If the Compact Par 18 Tri MKII is lowered from the ceiling or high joists professional trussing s...

Страница 7: ...od to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 1 Your name 2 Your address 3 Your phone number 4 A brief description of the sy...

Страница 8: ...ogy Full 3 in 1 RGB color mixing 4 Digits LED Control Display Double bracket Lumens 9600 Lux 2m 4170 Max Distance 10m Control Mode DMX512 DMX channels 1 3 4 6 Dimmer 0 100 Strobe 0 20Hz Beam Angle 28...

Страница 9: ...nnect all cables Always disconnect from electric mains power supply before cleaning or servicing Damages caused by non observance are not subject to warranty Set Up and Operation Follow the directions...

Страница 10: ...o firm trussing Leave at least 0 5 meter on all sides for air circulation 2 Turn on the music If the device is set to SU00 then the Compact Par will react to the beat of the music Please see page 13 f...

Страница 11: ...e combined number of channels required by all the fixtures on a serial data link determines the number of fixtures the data link can support Important Fixtures on a serial data link must be daisy chai...

Страница 12: ...t have any overlapping channels in order to control each Compact Par correctly If two or more Compact Par s are addressed similarly they will work similarly For address settings please refer to the in...

Страница 13: ...11 Menu Overview...

Страница 14: ...ilt in programs by using the Up Down buttons 3 When you select you can use a wide variety of manual color settings Press Setup to switch between the built in programs Menu Flash Frequency Flash Freque...

Страница 15: ...ect the required address from 3 You can also press the SETUP button to set 4 different DMX Modes Use the Up Down buttons to select the required Mode 1 Channel 3 Channels 4 Channels 6 Channels 4 Slave...

Страница 16: ...el 1 Red 0 255 Red gradual color brightness from 0 to 100 Channel 2 Green 0 255 Green gradual color brightness from 0 to 100 Channel 3 Blue 0 255 Blue gradual color brightness from 0 to 100 4 Channels...

Страница 17: ...0 Blue 250 144 152 Red 255 Blue 255 153 161 Red 220 Blue 50 162 170 Red 150 Green 50 Blue 100 171 179 Red 50 Green 180 Blue 220 180 188 Red 50 Green 220 Blue 100 189 197 Red 150 Green 220 198 206 Red...

Страница 18: ...safety relating and machine technical installations are to be inspected by an expert after every four years in the course of an acceptance test The operator has to make sure that safety relating and...

Страница 19: ...replacing the fuse 4 If all of the above appears to be O K plug the unit in again 5 If you are unable to determine the cause of the problem do not open the Compact Par as this may damage the unit and...

Страница 20: ...g or a defective fixture disturbing the link Bad data link connection Inspect connections and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120 Ohm ter...