background image

 

Connection with the mains

 

Connect the device to the mains with the power-plug. 
Always pay attention, that the right color cable is connected to the right place.

 

 

International 

EU Cable 

UK Cable 

US Cable 

Pin 

BROWN 

RED 

YELLOW/COPPER 

FASE 

BLUE 

BLACK 

SILVER 

NUL 

 

YELLOW/GREEN 

GREEN 

GREEN 

EARTH 

 

Make sure that the device is always connected 

properly

 to the earth!  

 
 
 
 
 
 
 
 
 
 

      

Return Procedure 

Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. 
Package must be clearly labeled with a Return Authorization Number (RMA number). Products returned 
without an RMA number will be refused. Highlite will not accept the returned goods or any responsibility. 
Call Highlite 0031-455667723 or mail 

[email protected]

 and request an RMA prior to shipping the fixture. 

Be prepared to provide the model number, serial number and a brief description of the cause for the 
return. Be sure to properly pack fixture, any shipping damage resulting from inadequate packaging is the 
customer’s responsibility. Highlite reserves the right to use its own discretion to repair or replace 
product(s). As a suggestion, proper UPS packing or double-boxing is always a safe method to use. 
 

Note: If you are given an RMA number, please include the following information on a piece of paper 
inside the box: 

1) Your name 
2) Your address 
3) Your phone number 
4) A brief description of the symptoms 
 
 

Claims 

The client has the obligation to check the delivered goods immediately upon delivery for any short-
comings and/or visible defects, or perform this check after our announcement that the goods are at their 
disposal. Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be 
reported to the carrier upon receipt of merchandise. 
 It is the customer's responsibility to notify and submit claims with the shipper in the event that a fixture is 
damaged due to shipping. Transportation damage has to be reported to us within one day after receipt 
of the delivery.  
Any return shipment has to be made post-paid at all times. Return shipments must be accompanied with 
a letter defining the reason for return shipment. Non-prepaid return shipments will be refused, unless 
otherwise agreed in writing. 
Complaints against us must be made known in writing or by fax within 10 working days after receipt of the 
invoice. After this period complaints will not be handled anymore. 
Complaints will only then be considered if the client has so far complied with all parts of the agreement, 
regardless of the agreement of which the obligation is resulting.  
 

 

Содержание Cameleon Spot 18-3

Страница 1: ...Compact Par 18 Tri MKII ORDERCODE 42592...

Страница 2: ...design and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep you our customer satisfied For more information iwant...

Страница 3: ...One Compact Par Sound control 8 Multiple Compact Pars Master Slave control 8 Multiple Compact Pars DMX Control 9 Fixture Linking 9 Data Cabling 9 Control Panel 10 DMX Control Mode 10 DMX Addressing 1...

Страница 4: ...ns If improving on this lifespan expectancy is of a higher priority place care in providing for lower operational temperatures This may include climatic environmental and the reduction of overall proj...

Страница 5: ...power cord is never crimped or damaged Check the device and the power cord from time to time If the external cable is damaged it has to be replaced by a qualified technician If the lens is obviously d...

Страница 6: ...the installation yourself Always let the installation be carried out by an authorized dealer Procedure If the Compact Par 18 Tri MKII is lowered from the ceiling or high joists professional trussing s...

Страница 7: ...od to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 1 Your name 2 Your address 3 Your phone number 4 A brief description of the sy...

Страница 8: ...ogy Full 3 in 1 RGB color mixing 4 Digits LED Control Display Double bracket Lumens 9600 Lux 2m 4170 Max Distance 10m Control Mode DMX512 DMX channels 1 3 4 6 Dimmer 0 100 Strobe 0 20Hz Beam Angle 28...

Страница 9: ...nnect all cables Always disconnect from electric mains power supply before cleaning or servicing Damages caused by non observance are not subject to warranty Set Up and Operation Follow the directions...

Страница 10: ...o firm trussing Leave at least 0 5 meter on all sides for air circulation 2 Turn on the music If the device is set to SU00 then the Compact Par will react to the beat of the music Please see page 13 f...

Страница 11: ...e combined number of channels required by all the fixtures on a serial data link determines the number of fixtures the data link can support Important Fixtures on a serial data link must be daisy chai...

Страница 12: ...t have any overlapping channels in order to control each Compact Par correctly If two or more Compact Par s are addressed similarly they will work similarly For address settings please refer to the in...

Страница 13: ...11 Menu Overview...

Страница 14: ...ilt in programs by using the Up Down buttons 3 When you select you can use a wide variety of manual color settings Press Setup to switch between the built in programs Menu Flash Frequency Flash Freque...

Страница 15: ...ect the required address from 3 You can also press the SETUP button to set 4 different DMX Modes Use the Up Down buttons to select the required Mode 1 Channel 3 Channels 4 Channels 6 Channels 4 Slave...

Страница 16: ...el 1 Red 0 255 Red gradual color brightness from 0 to 100 Channel 2 Green 0 255 Green gradual color brightness from 0 to 100 Channel 3 Blue 0 255 Blue gradual color brightness from 0 to 100 4 Channels...

Страница 17: ...0 Blue 250 144 152 Red 255 Blue 255 153 161 Red 220 Blue 50 162 170 Red 150 Green 50 Blue 100 171 179 Red 50 Green 180 Blue 220 180 188 Red 50 Green 220 Blue 100 189 197 Red 150 Green 220 198 206 Red...

Страница 18: ...safety relating and machine technical installations are to be inspected by an expert after every four years in the course of an acceptance test The operator has to make sure that safety relating and...

Страница 19: ...replacing the fuse 4 If all of the above appears to be O K plug the unit in again 5 If you are unable to determine the cause of the problem do not open the Compact Par as this may damage the unit and...

Страница 20: ...g or a defective fixture disturbing the link Bad data link connection Inspect connections and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120 Ohm ter...

Страница 21: ...ontrol Mode DMX512 DMX channels 1 3 4 6 Dimmer 0 100 Strobe 0 20Hz Beam Angle 28 Control Built in Programs Auto Sound controlled Master Slave DMX DMX controlled Music controlled via built in microphon...

Страница 22: ......

Отзывы: