background image

 

Multiple Compact Pars (DMX Control)

 

1.

 

Fasten the effect light onto firm trussing. Leave at least 0,5 meter on all sides for air circulation. 

2.

 

Plug the end of the electric mains power cord into a proper electric power supply socket.

 

3.

 

Use a 3-p XLR cable to connect the Compact Pars

4.

 

Link the units as shown in (figure 4), Connect a DMX signal cable from the first unit's DMX "out" socket 
to the second unit's "in" socket. Repeat this process to link the second, third, and fourth units.

 

5.

 

Supply electric power: Plug the end of the mains power cord into proper electric power supply 
sockets. Do so for all units and the controller. 

 

Multiple Compact Pars Pro Set Up

 

 

 
 
 
 
 
 
 
 

 Max. 30 Compact Pars

 

 

Fig. 4

 

 

 

Note : Link all DMX cables and set dip switches before connecting electric power 

 

6.

 

Do not supply power before the whole system is set up and connected properly. Design your show 
according to your DMX controller functions. See page 13 for more about DMX programming.  

 

 

Fixture Linking 

You will need a serial data link to run light shows of one or more fixtures using a DMX-512 controller or to 
run synchronized shows on two or more fixtures set to a master/slave operating mode. The combined 
number of channels required by all the fixtures on a serial data link determines the number of fixtures the 
data link can support.   

 
 

Important:

  

Fixtures on a serial data link must be daisy chained in one single line. To comply with the  
EIA-485 standard no more than 30 devices should be connected on one data link. 
Connecting more than 30 fixtures on one serial data link without the use of a DMX optically 
isolated splitter may result in deterioration of the digital DMX signal. 
 
Maximum recommended DMX data link distance: 100 meters 
Maximum recommended number of Compact Pars on a DMX data link: 30 fixtures 
@ 220V: 30 units may be connected in series 
@120V: 15 units may be connected in series 

 

Data Cabling 

To link fixtures together you must obtain data cables. You can purchase DAP Audio certified DMX cables 
directly from a dealer/distributor or construct your own cable. If you choose to create your own cable 
please use data-grade cables that can carry a high quality signal and are less prone to electromagnetic 
interference. 
 

DAP Audio Certified DMX Data Cables 

 

DAP Audio cable for allround use. 

bal. XLR/M 3 p. > XLR/F 3 p.  

Ordercode

 FL01150 (1,5m.), FL013 (3m.), FL016 (6m.), FL0110 (10m.), FL0115 (15m.), FL0120 (20m.). 

 

DAP Audio cable f

or the demanding user with exceptional audio-qualities and connector made by 

Neutrik®.

 Ordercode

 FL71150 (1,5m.), FL713 (3m.), FL716 (6m.), FL7110 (10m.). 

 

 

Содержание Cameleon Spot 18-3

Страница 1: ...Compact Par 18 Tri MKII ORDERCODE 42592...

Страница 2: ...design and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep you our customer satisfied For more information iwant...

Страница 3: ...One Compact Par Sound control 8 Multiple Compact Pars Master Slave control 8 Multiple Compact Pars DMX Control 9 Fixture Linking 9 Data Cabling 9 Control Panel 10 DMX Control Mode 10 DMX Addressing 1...

Страница 4: ...ns If improving on this lifespan expectancy is of a higher priority place care in providing for lower operational temperatures This may include climatic environmental and the reduction of overall proj...

Страница 5: ...power cord is never crimped or damaged Check the device and the power cord from time to time If the external cable is damaged it has to be replaced by a qualified technician If the lens is obviously d...

Страница 6: ...the installation yourself Always let the installation be carried out by an authorized dealer Procedure If the Compact Par 18 Tri MKII is lowered from the ceiling or high joists professional trussing s...

Страница 7: ...od to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 1 Your name 2 Your address 3 Your phone number 4 A brief description of the sy...

Страница 8: ...ogy Full 3 in 1 RGB color mixing 4 Digits LED Control Display Double bracket Lumens 9600 Lux 2m 4170 Max Distance 10m Control Mode DMX512 DMX channels 1 3 4 6 Dimmer 0 100 Strobe 0 20Hz Beam Angle 28...

Страница 9: ...nnect all cables Always disconnect from electric mains power supply before cleaning or servicing Damages caused by non observance are not subject to warranty Set Up and Operation Follow the directions...

Страница 10: ...o firm trussing Leave at least 0 5 meter on all sides for air circulation 2 Turn on the music If the device is set to SU00 then the Compact Par will react to the beat of the music Please see page 13 f...

Страница 11: ...e combined number of channels required by all the fixtures on a serial data link determines the number of fixtures the data link can support Important Fixtures on a serial data link must be daisy chai...

Страница 12: ...t have any overlapping channels in order to control each Compact Par correctly If two or more Compact Par s are addressed similarly they will work similarly For address settings please refer to the in...

Страница 13: ...11 Menu Overview...

Страница 14: ...ilt in programs by using the Up Down buttons 3 When you select you can use a wide variety of manual color settings Press Setup to switch between the built in programs Menu Flash Frequency Flash Freque...

Страница 15: ...ect the required address from 3 You can also press the SETUP button to set 4 different DMX Modes Use the Up Down buttons to select the required Mode 1 Channel 3 Channels 4 Channels 6 Channels 4 Slave...

Страница 16: ...el 1 Red 0 255 Red gradual color brightness from 0 to 100 Channel 2 Green 0 255 Green gradual color brightness from 0 to 100 Channel 3 Blue 0 255 Blue gradual color brightness from 0 to 100 4 Channels...

Страница 17: ...0 Blue 250 144 152 Red 255 Blue 255 153 161 Red 220 Blue 50 162 170 Red 150 Green 50 Blue 100 171 179 Red 50 Green 180 Blue 220 180 188 Red 50 Green 220 Blue 100 189 197 Red 150 Green 220 198 206 Red...

Страница 18: ...safety relating and machine technical installations are to be inspected by an expert after every four years in the course of an acceptance test The operator has to make sure that safety relating and...

Страница 19: ...replacing the fuse 4 If all of the above appears to be O K plug the unit in again 5 If you are unable to determine the cause of the problem do not open the Compact Par as this may damage the unit and...

Страница 20: ...g or a defective fixture disturbing the link Bad data link connection Inspect connections and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120 Ohm ter...

Страница 21: ...ontrol Mode DMX512 DMX channels 1 3 4 6 Dimmer 0 100 Strobe 0 20Hz Beam Angle 28 Control Built in Programs Auto Sound controlled Master Slave DMX DMX controlled Music controlled via built in microphon...

Страница 22: ......

Отзывы: