13
ACT Fresnel 150 WW
Product code: 34012
4.
Installation
Safety Instructions for Installation
WARNING
Incorrect installation can cause serious injuries and damage of property.
If trussing systems are used, installation must be carried out only by instructed or skilled persons.
Follow all applicable European, national and local safety regulations concerning rigging and trussing.
Installation Site Requirements
●
The device can be used indoors only.
●
The device can be mounted to a truss or another rigging structure in any orientation.
●
The minimum distance to other objects must be bigger than 0.5 m.
●
The maximum ambient temperature t
a
= 40 °C must never be exceeded.
●
The relative humidity must not exceed 50 % with an ambient temperature of 40 °C.
Rigging
The device can be mounted to a truss or other rigging structure in any orientation. Make sure that all
loads are within the pre-determined limits of the supporting structure.
CAUTION
Restrict the access under the work area during rigging and/or derigging.
To mount the device, follow the steps below:
Use a clamp to attach the device to the supporting structure, as shown in Fig. 06. Make sure that the
device cannot move freely.
Secure the device with a secondary suspension, for example a safety cable. Make sure that the
secondary suspension can hold 10 times the weight of the device. If possible, the secondary
suspension should be attached to a supporting structure independent of the primary suspension. Put
the safety cable through the safety eye (07), as shown in Fig. 06.
Fig. 06