WARNING
:
Maximum amount of units that may be daisy-chained is (A) 2 units AC 100V~(5.3Amps) or (B) 4 units AC 240V~ (2.08
Amps).Refer to Table1 for detailed information at various voltages.
Note
: For wiring of AC input connector, refer to Connecting SL LEDSPOT 300 to AC Power.
Table 1: SL LEDSPOT 300 Voltage vs. Current
Voltage(AC)
Total Current(A)
Maximum Number of units that can be linked together*
100
4.199
2
110
3.784
2
120
3.446
2
220
1.869
4
230
1.793
4
240
1.724
4
WARNING
:
*These figures are based on the Maximum Allowable Input Current of each fixture (and the Maximum power supply limit of
4
5
0 Watts ). Do not overload circuits!
IMPORTANT AC POWER CONNECTION NOTES:
·
When using the daisy-chain connection method, only connect the SL LEDSPOT 300 to the AC Output connection of another SL LEDSPOT
300 luminaire.
·
DO NOT CONNECT OTHER TYPES OF LUMINAIRES OR DEVICES!
·
Only use approved cable types.
·
Do not overload circuits!
·
Do not connect the SL LEDSPOT 300 to dimmed circuits.
Connecting Power
Units can be powered in one of two ways:
·
Direct connection to a AC power source using an AC input cable. For wiring of AC input connector, refer to Connecting SL LEDSPOT 300 to AC
Power.
·
Connection from the AC output of another SL LEDSPOT 300. When using this method, it is very important not to connect any other type of
equipment.
WARNING: Only connect other SL LEDSPOT 300 luminaires to the AC Output (Thru) connector of another SL LEDSPOT 300.
Connecting SL LEDSPOT 300 Luminaires to AC Power
Table 2, AC Input Connections describes how to connect power to your SL LEDSPOT 300. Field wiring of the SL LEDSPOT 300 is straight-forward.
A total of 3 wires/conductors is supplied to this unit.
Table 2: AC Input Connections
Wire Color
Purpose
Black
Main/Line(100
to
240
VAC)
White
Neutral
Green
Ground(Earth)