− 22 −
Fig.4
Fig.5
Fig.6
Fig.3
Fig.2
Completed
Rotate 180°
Clamp
Protective elbow
Clogging status indicator
Side cover
Filter cover
(3)
Changing the indicator's mount position
As viewed from the suction side, the clogging status indicator can be
mounted on either the left or right side. The customer should therefore mount
the indicator on the side where it can be most easily read, a decision
determined by the Mistresa's onsite installation conditions. Prior to shipment,
the indicator is mounted on the left side (as viewed from the suction side).
The procedure for changing this to a right-side mount is given below.
①
Release the clamp, remove
the bolts at the side-cover
side of the hinge which
connects the filter cover and
side-cover, then remove the
filter cover (both left and
right). (See Fig. 2 and 3)
②
Remove the 2 bolts which
secure the clogging status
indicator, rotate the indicator
and the protective elbow 180
degrees, then secure with the
2 bolts. (See Fig. 4)
③
Reverse the filter cover's left
and right sides, then reattach
the filter cover hinge to the
side cover. (See Fig. 5)