− 19 −
Unclamp the filter. Remove the cap.
Slide the filter box to take it out.
Remove the filter retainer.
*After replacing the filter and put the filter
retainer back in position, be sure of the
correct orientation of the filter retainer.
Remove the primary filter (thin one)
first, then space net and finally the
secondary filter (thick one).
Install the replacements in the order
of the secondary filter, space net,
and primary filter. For the primary
filter (2 pieces) and the secondary
filter (2 pieces), put each one piece
of them in place at a time with the
stamp “Mistresa Genuine Part” facing
the downstream (downstream of air
flow direction). (Do not attempt to
put all of them in at one time.
Otherwise, you may not be able to
install them in the right position.)
When installing the cap after
replacing the filters, be sure to
put the guide into the guide slot.
Otherwise, improper installation
of the cap could lead to oil leak.
*
Bottom
Top
Filter retainer
side view
③
CRH Series
(The CRH-100 and CRH-200T/E use a different replacement
procedure. Contact us.)
Primary and secondary filter replacement
(These filters can be reused after being washed)
1
2
3
4
5
6
【
CAUTION
】