E N
Nome file:
File name:
7524001 - ISTRUZIONI K-BALL - IT-EN-RUS.docx
Rev. 7 13/06/2013
19-28
8. Troubleshooting.
P
ROBLEM
C
AUSE
1
ST
S
OLUTION
2
ND
S
OLUTION
1. Water leak.
Gaskets or o-rings incorrectly
installed
Check correct gasket and o-ring
installation, see Fig. 2.
Contact specialised
technicians.
Fast connections not tight.
Tighten fast connections and cover,
Fig. 2.
2. Water brown.
The flowrate to the product is
inadequate (too high or too low).
Check flowrate as per Tab. 1.
Contact specialised
technicians.
The product is not adjusted to the
home pond and/or aquarium
volume.
Check home pond and/or aquarium
volume as per Tab. 1.
Water does not continuously flow to
the product.
Make sure home pond to the
product is continuous over a 24-hour
day.
Product just installed.
Clean the home pond removing
leaves, branches, etc.
If necessary, change the water.
The test tube is dirty.
Clean the test tube with a cotton ball
dampened in vinegar making sure
not to touch the test tube with your
bare hands
20
.
Light off.
Correctly install the UV unit cover as
illustrated in point 5.6.3.
3. Water green.
Flowrate to the product too high.
Check flowrate as per Tab. 1.
Contact specialised
technicians.
The product is not adjusted to the
home pond and/or aquarium
volume.
Check home pond and/or aquarium
volume as per Tab. 1.
The test tube is dirty.
Clean the test tube with a cotton ball
dampened in vinegar making sure
not to touch the test tube with your
bare hands
21
.
Flowrate to the product is
insufficient.
Make sure operations in point 5.6.1
were performed.
Light off.
Correctly install the UV unit cover as
illustrated in point 5.6.3.
4. Power cord
damaged.
Wear and/or negligence.
Contact specialised technicians.
-
5. Water flow at filter
output insufficient.
Counter-wash the filter.
Wash filter material.
Contact specialised
technicians.
Tab. 6.
9. Retail and spare parts and relevant documentation.
See Tab. 2 with reference to
Fig. 13
.
20
Do not touch the UV-C lamp and test tube with your bare hands. Impurities, dirt and grease on hands could jeopardise
product performance.
21
Do not touch the UV-C lamp and test tube with your bare hands. Impurities, dirt and grease on hands could jeopardise
product performance.
Содержание K-BALL 10000UV
Страница 2: ...Nome file File name 7524001 ISTRUZIONI K BALL IT EN RUS docx Rev 7 13 06 2013 2 28...
Страница 26: ...Nome file File name 7524001 ISTRUZIONI K BALL IT EN RUS docx Rev 7 13 06 2013 26 28...