ASSEMBLY
-13-
Attaching Air Hose
The regulator on the front of the sander has a
nozzle for attaching the air hose. Connect your
air hose and clamp it in place with a hose clamp
as shown in
Figure 11
. If you prefer, you can
replace the included air nozzle with a
3
⁄
8
" male
quick connect air coupling.
When the air hose is installed, regulate the air
pressure to 75 PSI. This is the required operating
pressure for this sander.
Installing
Sanding Belt
The sanding belt must be installed from the left
side of the sander. Before installing, make sure
the protective grease has been cleaned (as
described in “Cleaning Machine” instructions)
from the metal sanding belt rollers.
Pay special attention to the direction of the
arrows on the inside of the sanding belt. These
arrows show the direction that the sanding belt
is designed to rotate during operation. Facing
the inside of the left-hand access door, the
sanding belt will rotate counterclockwise.
Install the sanding belt as shown in
Figure 12
and center it on the rollers.
Figure 11.
Air hose attached to regulator.
Figure 12.
Installing sanding belt over rollers.
The arrows on the inside must point in the
same direction as belt rotation.
DO NOT exceed 75 PSI or damage to the air
system may result!
NOTICE
Keep the air pressure shut off when not in
use to reduce wear and tear on the air sys-
tem.
NOTICE