CONT’D
To remove the boiler, you will need to remove the 2
(two) screws as highlighted in the rendering to the
left. Place these screws in a safe, secure location
Tilting the boiler from the BACK forward (as depicted
in the illustration) slide the boiler off. This will leave
exposed the motor, universal, worm gear cover, and
flywheel. Place the boiler in a safe place where not
damage will occur.
Using a small flat head screwdriver, pry off the worm gear
cover, exposing the worm gear. At this point, you can
service the motor by de-soldering the leads and replacing
or changing. Please note that changing any electronics
in your locomotive will void your warranty.
Now is a good time to access the drive mechanism
should you need to lubricate and service. With
the boiler and motor removed you will need to
remove the screw cover on the cab floor. The two
screws secure the boiler bottom, which can now lift
straight out.