Character
Name, Function, Setting Range
Default Value
Display selection
CH1 PV / CH2 PV
• Selects items to be indicated on the PV/SV display.
PV (SV) switches while
is pressed in the PV/SV display mode. However, if CH1 or
CH2 difference or addition inclusive item is selected, PV (SV) does not switch.
• Selection range:
CH1 PV/SV display
CH2 PV/SV display
CH1 PV
(*)
CH2 PV
(*)
CH1 SV
CH2 SV
CH1 PV
(*)
CH1 SV
CH2 PV
(*)
CH2 SV
CH1 difference (addition)
CH1 PV
CH1 difference (addition)
CH2 PV
CH1 PV
CH1 difference (addition)
CH2 PV
CH1 difference (addition)
CH2 difference (addition)
CH1 PV
CH2 difference (addition)
CH2 PV
CH1 PV
CH2 difference (addition)
CH2 PV
CH2 difference (addition)
No indication
No indication
(*)
If CH difference or addition is selected for Input 1 (Input 2) block from the Block
function (Console software), CH1 and CH2 PV/SV displays do not indicate CH1 PV (CH2
PV) but CH difference or addition value.
For the Timer spec, if any item except “No indication” is selected, the CH2 PV/SV display
will indicate timer time. If CH2 inclusive item is selected during Display selection, the CH2
PV/SV display will go off (ineffective) for Potentiometer input spec or if Heating/Cooling
control output spec, External setting input spec or Transmission output spec is selected
from the Block function (Console software).
Indication time
00.00
• Sets the indication time of the displays from the final key operation till displays go off.
Displays remain lit when setting to 00.00.
Lights when any key is pressed while in unlit status.
• Setting range:
00.00 (Remains lit)
00.01 to 60.00 (Minute.Second)
Input sampling period
125 ms
• Selects the input sampling period.
•
: 25 ms
: 125 ms
: 250 ms
Potentiometer input zero adjustment
-200
• Adjusts potentiometer input zero (External setting scaling low limit value).
Available only for the Potentiometer input spec.
•
Adjustment method
:
Turn the potentiometer to the MIN side (counterclockwise) until the pointer matches the
minimum value, and press the
key. Automatically the potentiometer input zero will be
adjusted.
Potentiometer input span adjustment
1370
• Adjusts potentiometer input span (External setting scaling high limit value).
Available only for the Potentiometer input spec.
•
Adjustment method
:
Turn the potentiometer to the MAX side (clockwise) until the pointer matches the maximum
value, and press the
key. The potentiometer input span will be adjusted automatically.