SHINKO- 4
/
5 ton High Efficiency A5 Duct Technical Manual
32
Please use the accessory drain hose to connect the outlet of indoor unit with the PVC water pipe, and
then use the accessory clasp for chucking.
To prevent water from flowing backwards into the air conditioner while the air conditioner stops,
please lean the drainage pipe down toward outdoor (outlet-side) at a degree of over 1/100. And
please avoid any bulge or water deposit.
Do not drag the drainage pipe violently when connecting to prevent the body from being pulled.
Meanwhile, one support point should be set every 0.8 - 1.0m to prevent the drainage pipe from
yielding. Or you can tie the drainage pipe with the connecting pipe to fix it.
In case of prolonged drainage pipe, you had better tighten its indoor part with a protection tube to
prevent it from loosing.
The end of the drainage pipe should be over 50mm higher than the ground or the bottom of the
drainage chute, and do not immerse it in water. If you discharge the water directly into sewage, be
sure to make a U-form.
Charge water into water collection tray, after the drain water pipe is installed, check whether the
water can be drained smoothly and whether the joints are leakage.
After making sure that the water drains smoothly and no water is leaked, use a diabatic wool bushes
to preserve heat of the drain pipe. Otherwise, condensate will occur.
3.
Installation of Outdoor Units
Decide the correct way of conveying the equipment. Try to transport this unit with the original
package.
If the air conditioner needs to be installed on a metal part of the building, electric insulation must be
performed, and the installation must meet the relevant technical standards of electric devices.
Before install the outdoor unit, it should be checked first:
✓
The appliance shall not be installed in laundry.
✓
Install the unit where the air inlet and outlet are free from obstacles and strong wind.
Содержание SOVC-48CN1-RC7C
Страница 13: ...SHINKO Tropical R410A High Efficient A5 Duct Technical Manual 50Hz 12 6 Wiring Diagrams STB 48CWN1 STB 60CWN1 ...
Страница 22: ...SHINKO 4 5 ton High Efficiency A5 Duct Technical Manual 21 3 Service Space ...
Страница 23: ...SHINKO 4 5 ton High Efficiency A5 Duct Technical Manual 22 4 Wiring Diagrams SOVC 48CN1 RC7C SOVC 60CN1 RC5C ...
Страница 47: ...SHINKO 4 5 ton High Efficiency A5 Duct Technical Manual 46 Power supply phase sequence error ...
Страница 48: ...SHINKO 4 5 ton High Efficiency A5 Duct Technical Manual 47 Lack of Phase A B and C of power supply ...
Страница 50: ...SHINKO 4 5 ton High Efficiency A5 Duct Technical Manual 49 Over current protection of compressor ...
Страница 53: ...SHINKO 4 5 ton High Efficiency A5 Duct Technical Manual 52 Eeprom error ...