![Shinko BCS2 Скачать руководство пользователя страница 24](http://html.mh-extra.com/html/shinko/bcs2/bcs2_communication-instruction-manual_1258175024.webp)
24
(2) Read Slave address 1, Device identification information (Vendor name)
• A request message from the master
3.5 idle
characters
Slave
address
(01H)
Function
code
(2BH)
Sub-function
code
(0EH)
Data
(0400H)
Error check
CRC-16
(7327H)
3.5 idle
characters
1
1
1
2
2
• Response message from the slave in normal status (SHINKO TECHNOS CO., LTD.)
3.5 idle
characters
Slave
address
(01H)
Function
code
(2BH)
Sub-function
code
(0EH)
1
1
1
Data
(048100000100185348494E4B4F20544543484E4F5320434F2E2C204C54442EH)
31
Error check
CRC-16
(1C54H)
3.5 idle
characters
2
Data in the response message becomes as follows.
Data
Read Device ID code
1 Byte
04H
Conformity level
1 Byte
81H
More Follows
1 Byte
00H
Next Object ID
1 Byte
00H
Number of Objects
1 Byte
01H
List of Object ID
1 Byte
00H
List of Object length
1 Byte
24(18H)
List of Object value
Object length
S(53H)
H(48H)
I(49H)
N(4EH)
K(4BH)
O(4FH)
(20H)
T(54H)
E(45H)
C(43H)
H(48H)
N(4EH)
O(4FH)
S(53H)
(20H)
C(43H)
O(4FH)
.(2EH)
,(2CH)
(20H)
L(4CH)
T(54H)
D(44H)
.(2EH)