Instruction Manual Appendix
24
Surges
IEC 61000-4-5
Line to ground: 2kV line to line: 1kV
A
Conducted
Disturbances, induced
by RF fields
IEC 61000-4-6
3V/m, 150KHz-80MHz, 80%AM
A
Warning:
This equipment has been designed and tested to CISPR 11 Class A. In a domestic
environment it may cause radio interference, in which case, you may need to take measures to
mitigate the interference.
Do not use this device in close proximity to sources of strong electromagnetic radiation (e.g.
unshielded intentional RF sources), as these may interfere with the proper operation.