background image

 

Introduction 

 

Thank you for purchasing this Shindaiwa Tower Light. 

 

 

This manual has been created to ensure safe usage of this tower light. 
Be  sure  to  read  this  manual  before  operation.  Improper  operation/handling  of  this  tower 
light will result in an accident or malfunction. 

 

 

Handling  and  operation  of  this  tower  light  can  only  be  performed  by  persons  who  fully 
understand  the  contents  of  this  manual,  and  are  capable  of  safe  handling/operation. 
Persons who suffer from an illness, are taking medicine, or are not feeling well to a degree 
that safe operation would be hindered must not operate this tower light. 

 

 

Work performed using this tower light and handling/operation of this tower light must be in 
accordance with corresponding laws and regulations based on such laws. 

 

 

Be  sure  to  always  include  this  manual  when  loaning  out  this  tower  light  and  instruct 
operating personnel to carefully read this manual before operation. 

 

 

Store this manual in a specified location where it will be secure and available for consulting 
at any time. 
Order another copy from the authorized distributor where this tower light was purchased if 
this manual becomes lost, dirty or damaged. 

 

 

Consult  with the  authorized distributor  where this  tower light  was purchased if  you  have 
any inquiries regarding any points related to this tower light and manual. 
Be  sure  to  provide  the  model  name  and  serial  number  when  inquiring  about  this  tower 
light. 

 

 

If disposing of this tower light, do so in a manner that is in compliance with laws related to 
industrial waste. Contact the authorized distributor where this tower light was purchased if 
you have any inquiries regarding proper disposal. 

 

 Caution notice ranks in this manual are classified as follows. 

 
 
 
 
 
 
 
 
 
 

 

Not that "     

CAUTION

" items can also lead to major accidents under some circumstances 

if not correctly followed. All caution notices are important. Be sure to follow all of them. 

 

 
 
 
 
 
 
 
 
 
 
 

WARNING

:  Indicates  a  potentially  hazardous  situation  which,  if  not  avoided,  can 

result in death or serious injury. 

 

CAUTION

:  Indicates  a  potentially  hazardous  situation  which,  if  not  avoided,  can 

result in minor or moderate injury and property damage. 

 

<Note>

Notes  regarding  care  of  and  achieving  optimal  service  from  this  tower 
light. 

Содержание SL433IDG

Страница 1: ...MANUAL Tower Light SL433IDG SL433IDG A S1W X753 006 63 0 X753809 0601 CAUTION Do not operate the Tower Light or any other appliance before you have read and understood the instructions for use and ke...

Страница 2: ......

Страница 3: ...onsulting at any time Order another copy from the authorized distributor where this tower light was purchased if this manual becomes lost dirty or damaged Consult with the authorized distributor where...

Страница 4: ...Outriggers 7 5 4 Using the Lamp Fittings and Lamp Fittings Frame 8 5 5 Lifting Lowering the Mast 10 6 Operating Procedures Tower Light 11 6 1 Turning on the Lamps 11 6 2 Turning off the Lamps 12 7 Tra...

Страница 5: ...e always be sure to position the tower light on a level surface with a solid foundation place wheel chocks and lower the mast until it is at the lowest position WARNING DROPPING INJURY If moving the t...

Страница 6: ...e where exposed to rain Locations of Warning Caution labels Replace warning and caution labels with new ones if they become damaged and difficult to read Order labels by using the part number indicate...

Страница 7: ...l Length mm 1 423 Total Width mm 1 070 Outer Tire Width mm 790 Total Height mm 1 655 Dry Weight kg 169 Equipped Generator Model IDG3100M Generator Type Multipolar revolving magnetic field type Voltage...

Страница 8: ...igger Latch Winch Handle Lamp Fitting Angle Adjustment Lever Rotation Handle Lamp Fitting Leg Mast Pulley Cover Lifting Lug Wheel Tire Tow Hook Dolly Handle Winch Brake Stopper Lamp Fittings Frame Lam...

Страница 9: ...can result in deformation and damage 5 2 Applying the Wheel Brakes Note If the brake force is weak adjust the wheel air pressure and brake stopper angle Refer to 10 Inspection Maintenance 1 Releasing...

Страница 10: ...e outer side away from the mast side with your foot 2 Storing the Outriggers Push the outrigger lever towards the mast side with your foot to release the lock With the lever pushed pull up the outrigg...

Страница 11: ...If changing the light projection direction in the vertical direction If changing all lamp fittings at the same time Note Adjust the left and right sides individually because they move independently Ho...

Страница 12: ...ings for Movement or Transport Position the lamp fittings so they face forward and tighten the rotation handle to secure them Position the lamp fittings so they face down and tighten the lamp fittings...

Страница 13: ...ition The highest position is where you can see the arrow label Forcibly turning the winch can result in malfunction and breakage of the winch wire or pulley 2 Lowering the Mast Turn the winch handle...

Страница 14: ...Manual 1 2 3 4 6 Operating Procedures Tower Light 5 Lower the mast if using in strong wind that causes the lamp fittings to sway severely Although the mast can withstand wind speeds up to 20 m s when...

Страница 15: ...to the desired height Refer to 5 5 Lifting Lowering the Mast 6 2 Turning off the Lamps Lower the mast Refer to 5 5 Lifting Lowering the Mast Turn the generator Output switch to OFF to turn off the lam...

Страница 16: ...nerator When scooping up the tower light generator with a forklift to transport it do not move forward down a steep incline or rotate the forklift suddenly Doing so could result in the tower light gen...

Страница 17: ...erator Position the lamp fittings so they face straight forward and fully insert the forks aligned with the fork position labels and scoop up the equipment Note Always be sure to insert the fork inser...

Страница 18: ...the lamp perform these procedures in the reverse order to install 8 Lamp Replacement Procedures 1 2 3 4 5 Lamp Fittings Handle Tighten Loosen Angle Adjustment Lever Socket Stop Butterfly Nut Lamp Fit...

Страница 19: ...the power cord from the generator output outlet Remove the bolt and nut securing the lifting lug and generator and push the lifting lug to the mast side Remove the eight bolts securing the metal holde...

Страница 20: ...s Tighten 2 Coupler Terminal Disconnection breakage Connect 3 Securing Nut of Lamp Fitting Leg Looseness Tighten 4 Lamp Fittings Handle Looseness Tighten 5 Rotation Handle Looseness Tighten Mast 6 Mas...

Страница 21: ...e following procedures to correct the angle of the brake stopper Move this tower light to a level location and place wheel chocks Release the wheel brakes Refer to 5 2 Applying the Wheel Brakes Loosen...

Страница 22: ...he mast between the second and third stages one each on the right and left Accordingly lower the mast to the lowest position and apply spray grease from above 3 Providing Grease to the Front Wheel Ste...

Страница 23: ...oosen the wire tension Store the lamp fittings Refer to 5 4 Using the Lamp Fittings and Lamp Fittings Frame Move the tower light to the storage location and apply the wheel brakes 11 Long Term Storage...

Страница 24: ...ce the lamps Mast does not go up Mast does not easily slide Apply grease to moving parts Poor pulley rotation Apply grease to pulleys Foreign material is caught in the mast Repair Mast comes down Winc...

Страница 25: ...MEMO...

Страница 26: ...MEMO...

Страница 27: ...MEMO...

Страница 28: ...2017...

Отзывы: