  Danger : Suffocation from exhaust fume 

z

  Exhaust fume from the engine contains many elements harmful to human. Do not operate 

this equipment in poorly ventilated area, such as inside a room or in a tunnel. 

 

Caution : Suffocation from exhaust fume 

z

  Do not point the exhaust fume toward pedestrians or building. 

 

Caution : Fire 

z

  Temperature around muffler and exhaust can get extremely high. Keep any inflammable 

items (such as fuel, gas, paint, etc.) away from the equipment. 

z

  Always operate this equipment on flat surface and, at least 1 meter away from any objects 

(wall, box, etc.) 

             

Caution : Injuries 

z

  Always place the equipment on flat and stable surface, to keep the equipment from sliding. 

Be sure to lock the wheels for the wheeled models. 

z

  When starting the engine, turn off the connected equipment and set the circuit breaker to 

OFF position. 

  Turn the circuit breaker to OFF position. 

  Turn the fuel lever to OPEN. 

  Turn the Slow-Down switch to ON. 

  When the temperature is below 5

℃,

turn the starter 

switch to PREHEAT. The preheating lamp flashes 15 

seconds. The lamp comes off when the PREHEAT fin-

ishes. 

  Turn the starter switch to START to start the engine by the 

starter motor. 

         <Caution> 

z

  Do not drive the starter motor for more than 15 seconds successively. 

z

  If you need to restart, wait for 30 seconds or more before retry. 

  Release the starter switch, as soon as the engine is started. 

<Caution> 

z

  Once the engine is started, do not turn the starter switch to START. 

  Make sure the frequency to the monitor on the control panel. 

  Keep the engine idle for about 5 minutes.     

   

 

 
 

 

 

 

 

 

       

FUEL LEVER

 

CLOSE

 

OPEN

 

SLOW-DOWN SWITCH

 

STARTER SWITCH

 

PREHEAT LAMP

CIRCUIT BREAKER

 

 DGW311DM  

PREHEAT LAMP

 

STARTER SWITCH

 

SLOW-DOWN SWITCH

 

CIRCUIT BREAKER 

 DGW311L  

Содержание DGW311DM

Страница 1: ...cking Fuel Engine Oil and water Leakage 6 5 Checking Battery 7 Operation 7 1 Initializing Preparation 7 2 Stopping Generator Welder 8 Welding Operation 8 1 Selection Welding Cable 8 2 Polarity 8 3 Con...

Страница 2: ...oughly reviewing and understanding the contents of this manual z Please attach this manual if the equipment will be sub leased z Please store this manual near the equipment for easy reference Followin...

Страница 3: ...key Danger Burns z Do not open the radiator cap while operating this equipment or immediately after stopping the equipment to avoid sustaining burns from hot vapor Danger Injuries z Close all doors an...

Страница 4: ...s wait until the equipment cools down before placing any covering materials for storage Caution Burns z Do not touch the engine and muffler during operation and immediately after stopping the equip me...

Страница 5: ...ing figure When ordering the label use the following part numbers Suffocation from exhaust fume No 19402 00194 Suffocation from welding fume No 19402 00195 Electric shock No 19402 00192 Electric shock...

Страница 6: ...1 Phase Rated Voltage V 220 110 380 220 400 230 415 240 Frequency Hz 60 50 3 Phase 10 Rated Output kVA 1 Phase 6 8 Rated Speed min 1 3600 3000 Power Factor 3 Phase 0 8 1 Phase 1 0 AC Generator Rating...

Страница 7: ...CH STARTER SWITCH MONITOR LAMP FUEL GAUGE HOUR METER WELDING OUTPUT TERMINAL CIRCUIT BREAKER 3 PHASE VOLT METER 1 PHASE OUTPUT RECEPTACLE EARTH GROUNDING TERMINAL 3 PHASE 1 PHASE OUTPUT TERMINAL 1 PHA...

Страница 8: ...IRCUIT BREAKER CURRENT ADJUSTMENT DIAL SLOW DOWN SWITCH STARTER SWITCH MONITOR LAMP 3 PHASE VOLT METER EARTH GROUNDING TERMINAL HOUR METER FUEL GAUGE WELDING OUTPUT TERMINAL 3 PHASE 1 PHASE OUTPUT TER...

Страница 9: ...lly touching cooling fan and fan belt Caution Burns z Do not touch the engine and muffler during operation and immediately after stopping the equipment for the temperature can reach extremely high z W...

Страница 10: ...found normal when you have checked them in the first place If the fuse is burned out consult with our authorized distributor or our engineering section because there may be an abnormality of electric...

Страница 11: ...starter switch from STOP to Run Turn Push up the circuit breaker lever to ON position Push the test button When the button is pushed the earth leakage indication lamp turns ON and the circuit breaker...

Страница 12: ...mption whenever welding operation or electric supply is not performed In the case of using the Slow Down feature turn the Slow Down switch to ON The engine automatically moves to high speed when weldi...

Страница 13: ...lt Danger Burns z Do not open the radiator cap while operating this equipment or immediately after stopping the equipment to avoid sustaining burns from hot vapor Caution Burns z Do not touch the engi...

Страница 14: ...r the fuel level in the tank Add if necessary Caution z Use Diesel fuel ASTM D975 No 2 D in the event ambient temperature reaches down to 5 z The engine is designed to use either No 1 D or No 2 D Dies...

Страница 15: ...ible gas so keep it away from fire and sparks Check the fluid level If the level is near or lower than the LOWER level add distilled water until the fluid level reaches the UPPER level Make sure that...

Страница 16: ...turn off the connected equipment and set the circuit breaker to OFF position Turn the circuit breaker to OFF position Turn the fuel lever to OPEN Turn the Slow Down switch to ON When the temperature...

Страница 17: ...ution z Keep the Slow Down switch ON unit the air is completely extracted out unit the engine speed becomes stable otherwise the engine may disorder 7 2 Stopping Generator Welder Turn Push down the br...

Страница 18: ...welding rod holder and connect the other cable to a crimping terminal and a material holder Connect the welding cables to the output terminals In terms of DGW311DM connect cables to the welding outpu...

Страница 19: ...y attention to the airflow direction and sufficient ventilation also in order to prevent from inhaling the fume Caution Injuries to eyes and skin z Be sure to wear spark protection glass es Refer to t...

Страница 20: ...tor ECO SINGLE DUAL Current Adjustment Current Adjust Dial A Current Adjust Dial A Current Adjust Dial A B 8 5 2 DGW311L Start the engine Refer to No 7 1 Initializing Preparation Adjust the current by...

Страница 21: ...put per one receptacle is 1 5kVA and one terminal set is 3kVA The total output for the receptacles and the terminal set is 6kVA 9 1 2 DGW311L W 380A DGW311L W 400A DGW311L W 415A 9 1 2 1 3 Phase Outpu...

Страница 22: ...nnot be judged only by the rated output or the power consumption due to the efficiency and characteristic of the components DGW311DM W 220B DGW311L W 220B Applicable Load For reference purpose only 60...

Страница 23: ...han the rated power consumption Therefore consult with our authorized distributor or our engineering section to clarify z When connecting 2 or more sets to use start the load one by one not to start t...

Страница 24: ...supply exceeds the rated output overload the circuit breaker activates to trip off in order to shut off the circuit When the load in operation stops check the breaker When the circuit breaker is posi...

Страница 25: ...elow 4 9kVA or below 4 0mm 170A 4 2kVA or below 3 3kVA or below 5 0mm 220A 2 0kVA or below 1 6kVA or below 6 0mm 260A 0kVA or below 0kVA or below 11 Checking and Maintenance Danger Electric Shock Inju...

Страница 26: ...ean Radiator Fin 14 Change Hose Fuel Radiator Change Vibration Absorbing Rubber or 2 years 15 Adjust Engine Valve Clearance Adjust Adjust 16 Check Adjust Injection Nozzle 17 Check Adjust Injection Pum...

Страница 27: ...replace the air filter element and reinstall it in reverse order Caution z Clean more frequently if used in dusty environment z Air Filter Element Part No 121465 12510 Yanmar How to clean air filter e...

Страница 28: ...all the reservoir tank back and fill the radiator with coolant water up to radiator filler neck Total cool ant water Capacity is 3 1 liter Reinstall the radiator cap Install the top plate back 12 Long...

Страница 29: ...ting guide contact the authorized distributor or our engineering sec tion to request the repair Symptoms Possible Cause Corrective Actions Starter motor does not start 1 Weak Battery 2 Dead Battery 1...

Страница 30: ...T LIMITATION 2 Stop welding Slow Down does not activate 1 Short circuit of welding cable 2 The power consumption of the load is 0 5A or below 1 Repair the short circuit 2 Turn the Slow Down switch to...

Страница 31: ...30 14 Engine Wiring Diagram DGW311DM DGW311L...

Страница 32: ...31 220V 60Hz 15 Generator Wiring Diagram...

Страница 33: ...32 DGW311L W 220B 220V 60Hz...

Страница 34: ...33 DGW311L W 380A 380V 50Hz...

Страница 35: ...34 DGW311L W 400A 400V 50Hz...

Страница 36: ...35 DGW311L W 415A 415V 50Hz...

Страница 37: ...Head Office Telephone 81 82 849 2220 FAX 81 82 849 2481 71902 94012...

Отзывы: