14
6-4 Checking Fuel, Engine Oil and Water Leakage
Caution : Fire
z
Always wipe any drip of Diesel fuel or oil. Do not use this equipment when a leak is found.
Repair the equipment before use.
Be sure to check for any fuel leak at the hose connection, and oil and coolant/water by opening
side doors. When checking for any fuel leak, open a fuel lever and be sure to close the fuel lever
after checking.
6-5 Checking Battery
Caution : Injuries to eyes and skin
z
Battery fluid contains diluted sulfuric acid. Avoid contact with eyes, skin or clothing. If the acid
comes in contact, especially with eyes, flush with a lot of water, and contact your physician
immediately.
Caution : Explosion
z
When the liquid level is below the LOWER level, never use the equipment nor recharge the
battery.
z
Battery may emit some combustible gas, so keep it away from fire and sparks.
①
Check the fluid level. If the level is near or lower than the
LOWER level, add distilled water until the fluid level reaches
the UPPER level.
②
Make sure that the battery cables are firmly secured to the
posts. Tighten the clamps if necessary.
<Caution>
z
Check the hydrometer of the battery fluid. If it falls below 1.23, the battery requires recharg-
ing. Please consult with our authorized distributor or our engineering section.
Replacing
battery
①
Remove the clamp and cable from negative (-) post in
the battery. (Remove always negative side first)
②
Remove the hold-down clamp from the battery.
③
Remove the clamp and cable from positive (+) post in
the battery.
④
Remove the battery from the seat.
※
Reinstall a new battery in the reverse order. (Install always the cable to the positive (+) post
in the new battery first.)
<Caution>
z
Use the following battery.
46B24L
7. Operation
7-1 Initializing/Preparation
UPPER
LEVEL
TERMINAL
LOWER
LEVEL
+
TERMINAL
-
TERMINAL
BATTERY
HOLD-DOWN
CLAMP
INS-CAP
Содержание DGW311DM
Страница 31: ...30 14 Engine Wiring Diagram DGW311DM DGW311L...
Страница 32: ...31 220V 60Hz 15 Generator Wiring Diagram...
Страница 33: ...32 DGW311L W 220B 220V 60Hz...
Страница 34: ...33 DGW311L W 380A 380V 50Hz...
Страница 35: ...34 DGW311L W 400A 400V 50Hz...
Страница 36: ...35 DGW311L W 415A 415V 50Hz...
Страница 37: ...Head Office Telephone 81 82 849 2220 FAX 81 82 849 2481 71902 94012...