![Shindaiwa DGW300MS/UK Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/shindaiwa/dgw300ms-uk/dgw300ms-uk_operators-manual_1257639021.webp)
- 19 -
8-5. Welding
Caution: Suffocation from welding fumes
Be sure to wear a fume proof mask during operation, because welding fumes
contains poisonous gas and dust. Pay attention to the airflow direction and
sufficient ventilation also in order to prevent from inhaling the fume.
Caution: Injuries to eyes and skin
Be sure to wear spark protection glasses (Refer to the table below),
long-sleeve shirts, gloves, etc. in order to protect eyes and skin from harmful
spark in welding.
Standard for Spark Protection Glass
No.
7
8
9
10
11
12
13
Welding Current (A)
30-75
76-200
201-400
Caution: Fire
Keep any inflammable items and combustible materials away from welding
area.
Caution: Burns
Be sure to wear leather gloves, apron, shoe covers, eye protection
glasses/mask, safety shoes, safety cap and long sleeve shirts, as
welding creates hot sparks.
The adjustable output range by the Current Adjustment Dial depends on the
position each of the Idle Control Switch.
①
Turn the Idle Control Switch to [ECO] or [AUTO] or [HIGH], according to the
operation.
②
Set the current amperage by the Current Adjustment Dial.
<Caution>
The values on the Current Adjustment Dial are for reference only. The Cable
length or the ambient temperature each affects the value.
When the remote control box is used, the value may change to some degree.
IDLE
CONTROL
SWITCH
WELDING OUTPUT
TERMINALS
CURRENT
ADJUSTMENT