![Shindaiwa DGW300MS/UK Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/shindaiwa/dgw300ms-uk/dgw300ms-uk_operators-manual_1257639015.webp)
- 13 -
Danger: Injuries
Do not open the radiator cap while operating this equipment or immediately
after stopping the equipment, to prevent burns from hot steam or water.
Caution: Burns
Do not touch the engine and muffler during operation and immediately after
stopping the equipment, for the temperature could reach extremely high
temperature.
Check to see if the coolant/water level is between FULL and LOW levels in the
coolant sub tank. If the coolant/water is below the LOW level, fill the tank and the
radiator accordingly.
(1) Filling to the Coolant Sub Tank
①
Remove the coolant sub tank cap.
②
Fill up the coolant sub tank to the FULL level.
③
Install the cap back.
(2) Filling the Radiator
①
Open the top plate.
②
Remove the radiator cap.
③
Fill the radiator up to the top.
④
Install the cap back and tighten.
⑤
Close the top plate.
<Caution>
Use Long Life Coolant (LLC), for prevent freezing
and corrosion. (30%mixture LLC is filled when
shipped from factory)
Mixture ratio of the coolant should be 30%-45%,
depending on the ambient temperature.
Replace LLC at every year or 2000 hours.
Mixture Ratio (for reference only)
Lowest Ambient
Temperature
-15
℃
-20
℃
-30
℃
Mixture Ratio
30%
35%
45%
6-3. Checking Fuel
Caution: Fire
Always wipe away any drip of fuel. Do not use this equipment if a leakage is
found. Repair the equipment before use.
Check for the fuel level in the tank. Add if necessary.
LOW
FULL
COOLANT
SUB TANK
CAP
COO-
LANT
SUB
TANK
TOP PLATE
WATER INLET
RADIATOR
CAP