![Shindaiwa DG60MI Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/shindaiwa/dg60mi/dg60mi_owners-and-operators-manual_1257712033.webp)
30
RS2 terminal
RS1 terminal
(2) Auto Start
This generator has an Auto Start function that automatically start the engine by closing the
RS1/RS2 terminals.
The engine stops automatically when the RS1/RS2 terminals open.
Before operating Auto Start, connect the RS1/RS2 terminals to the equipment.
< Note >
When the RS1/RS2 terminals to close and press the Auto Mode Button, the engine will start up
immediately.
Set frequency of the Controller. (Refer to section"
5-4. Frequency change
" )
Turn the circuit breaker to OFF position.
Turn the Power Switch to ON position.
< Note >
When turn the Power Switch to the ON position, the “Low Oil Pressure” and “High Coolant
Temperature” warning indicators will illuminate, but all indicator lights will turn off when the
engine is started.
Press the Manual Mode Button.
Press the Start Button to start the engine.
Adjust frequency with the Frequency Adjust Screw.
Rated frequency
No-load frequency
50Hz(1500min
-1
)
52.5Hz(1575min
-1
)
60Hz(1800min
-1
)
63.0Hz(1890min
-1
)
Adjust voltage using the voltage regulator dial.
50Hz Operation
400V [200V]
60Hz Operation
440V [220V]
* The values in brackets are for when set to 200/220V.
Press the Stop Mode Button to shut off the engine.
Press the Auto Mode Button.
Turn the Circuit Breaker to ON position.
The engine starts when the RS1/RS2 terminals close.
<
Note >
Please keep in mind that the muffler may emit some smoke when engine is started.
The battery is always drained while Auto Mode is selected. Start the engine at least once a
week to charge the battery.
11
10
9
8
7
6
5
4
3
2
1
Содержание DG60MI
Страница 2: ......
Страница 48: ...45 1 400 440V 13 Generator Circuit Diagram...
Страница 49: ...46 2 200 220V...
Страница 50: ...47 14 Engine Electrical Circuit Diagram...
Страница 51: ......
Страница 52: ...2019...