background image

II. Product Introduction

Mini-type Clean-water Centrifugal Electric Pumps include those of the series of SHF(m), 

CP(m), PRm, SGA(m), PX(m), PUM, 2SGP(m), SGT, KSW, PC, CPH, and ZDK (hereinafter 
referred to as the “Electric Pump”). The Electric Pump is mainly composed of such three parts as 
the motor, the water pump, and the seal. The motor is an asynchronous motor. The pump adopts 
the centrifugal-type impeller-volute (guide vane) structure, featured by high water yield and stable 
operation. The pumps hereunder can be divided into non self-priming pumps and self-priming 
pumps. A product of ZDK model has the function of self-priming. The seal: There is a single 
mechanical seal between the water pump and the motor, used as the motive seal. The water 
blocking ring revolving on the spindle provides assistance in water throwing and separation and at 
the place of sealing of each fixed spigot is an O-shaped rubber seal ring used as the static seal.

The Electric Pumps of the models hereunder, with advantages such as small volume, light 

weight, compact structure, and easy installation, can be widely applied to irrigation and spray 
irrigation for farms, spray irrigation and watering in gardens, water supply to vegetables 
greenhouses, water supply and drainage of breeding industry, and lifting of water from wells. 

III. Operating Conditions

The Electric Pump shall be able to operate continuously and normally in the following 

operating conditions:

1. The ambient temperature does not 40

2. The temperature of the medium ranges from 0 to +40°C (the temperature of the medium to 

be conveyed by a CPH or PUM pump is between 0 and +90

); 

3. The pH value of the medium is 6.5~8.5;
4. The mass ratio of the solid impurities contained in the medium is not higher than 0.1% and 

the particle size is not more than 0.2mm 

5. The voltage and the frequency of the power supply meet the requirements in the 

nameplate of the Electric Pump, relating to the nominal voltage and frequency and the scope of 
the fluctuation of voltage is ±10% of the nominal value. 

Содержание 2SGP

Страница 1: ...Vortex Type Micro Clean Water Pump Models SHF m CP m PRm SGA m PX m PUM 2SGP m SGT KSW PC CPH ZDK Mini type Clean water Centrifugal Electric Pump SERVICE MANUAL...

Страница 2: ...Precautions II Product Introduction III Operating Conditions IV Structure Diagram V Pump Wiring Diagram VI Installation Diagram VII Instructions for Installation VIII Maintenance IX Troubleshooting C...

Страница 3: ...ice properly and reliable grounding shall be provided at the place where the grounding sign of the Electric Pump or the cable lies the grounding conductor shall be connected to the terminal marked and...

Страница 4: ...inding insulation may lead to electrical leakage In winter when anti freezing measures are taken for a water pump hereunder no ammable material shall be used to cover the pump or its motor for freeze...

Страница 5: ...d as the static seal The Electric Pumps of the models hereunder with advantages such as small volume light weight compact structure and easy installation can be widely applied to irrigation and spray...

Страница 6: ...8 9 10 11 12 Rubber washer Capacitor Terminal box Nut of the terminal box Cable Cable sheath Rubber washer Terminal board Motor Housing Foot Hexagon socket head screw O ring 13 14 15 16 17 18 19 20 2...

Страница 7: ...ternal teeth lock washer 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Cross recessed pan headed self tapping screw Press plate for the cable Cable sheath Cable End cover Spring washer Hexagon headed bolt Fa...

Страница 8: ...g ring Key 1 2 3 4 5 6 7 8 9 10 11 Stator Cross recessed pan headed screw Terminal box cover Capacitor Press plate for the cable Cable sheath Cable Motor case Foot Hexagon bolt Mechanical seal 12 13 1...

Страница 9: ...16 17 18 Coupling Air faucet Dust cover Rotor Foot Stator motor case Rubber gasket Terminal box assembly Cross recessed small pan head screw External teeth lock washer Cross recessed ange face screw C...

Страница 10: ...1 2 3 4 5 6 7 8 9 10 11 12 13 14 I shaped hex nut Spring washer Flat washer Impeller Pump cover Mechanical seal Waterproof ring Framework oil seal O ring Coupling Spring washer Hexagon bolt Hexagon bo...

Страница 11: ...Copper bush Key Mechanical seal Waterproof ring 1 2 3 4 5 6 7 8 9 10 11 Coupling Rubber gasket Outlet joint Stator Motor Case Bottom of the terminal box Rubber washer Terminal box cover Nameplate Sel...

Страница 12: ...minal Grounding symbol Capacitor 1 2 3 4 5 6 7 8 9 10 11 12 13 Cross recessed small pan head screw Terminal box Nameplate Cable Cable locking head O ring Terminal Heat shrink tubing Press plate for th...

Страница 13: ...sed ange face screw 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Terminal board Cross recessed pan headed self tapping screw Press plate for the cable Coupling Rubber gasket Shaft sleeve Mechanical seal Cab...

Страница 14: ...Supply of Tap Water V Pump Wiring Diagram VI Installation Diagram Wiring of single phase pump Wiring of three phase pump Capacitor Yellow green Subline Secondary winding Main winding Common line Blac...

Страница 15: ...Farm Irrigation Water Supply by Water Tower on Roof and Downward Pressurization of Water Tower...

Страница 16: ...resistance limit to ensure that the pipe will not be deformed by heat for such deformation might make the pipe become broken and hence causing water leakage 3 After connecting the upper end of the inl...

Страница 17: ...P A B C OUTPUT A B C INTPUT FUSE AC 380V NOTICE Connected to the sewer line Prior to the initial use please fill the chamber of the Electric Pump with water and then power on it so as to avoid dry run...

Страница 18: ...over 5 minutes Where the Electric Pump operates with no water ow change inside the pump body resulting in the rise of the temperature and the pressure of the liquid in the pump body leakage may be ca...

Страница 19: ...in parts and components carry out rust proof treatment and keep it properly at a dry and well ventilated place NOTICE 1 Regularly inspect the insulation resistance between the enclosure and the windin...

Страница 20: ...eliable 2 Inspect the exibility of the bottom valve and the check valve and remove obstacles 3 Adjust or replace the seal 4 Check the water level and adjust the installation height of the Electric Pum...

Отзывы: