IX. Troubleshooting

Fault 

Cause

Remedy

The motor does 
not revolve.

1. The cable of the Electric Pump is 
connected badly or broken. 
2. The impeller is blocked. 
3. The stator winding is burnt. 
4. The voltage is low. 
5. The voltage of the cable drops too 
much. 
6. The capacitor is damaged. 

1. Inspect the terminal or replace the cable. 
2. Correct the blocked part or remove sundries. 
3. Re-insert the winding or carry out overhaul.
4. Adjust the supply voltage to a value within the 
range of 0.9-1.1 times the rating. 
5. Thicken the cable as required.
6. Replace the damaged capacitor with another 

The motor 
operates but 
the water pump 
has no water 
flow. 

1. There is air leakage at the inlet pipe. 
2. The bottom valve or check valve is not
opened or is blocked. 
3. Air gets in through the seal. 
4. The water level is lower than the 
suction lift limit of the Electric Pump. 
5. The water pump is not filled with 
water. 
6. The impeller is damaged. 
7. There is a high pipe resistance and 
an ill-suited pump model selected is not 
suitable.  

1. Check whether the sealing at the inlet pipe or 
any connection is perfect and ensure that the 
sealing is reliable. 
2. Inspect the flexibility of the bottom valve and 
the check valve,

 

and remove obstacles. 

3. Adjust or replace the seal. 
4. Check the water level and adjust the 
installation height of the Electric Pump. 
5. Again fill the pump body with water. 
6. Replace the impeller. 
7. Reduce the bends of the pipeline and re-select 
a model.  

The flow is 
insufficient.

1. The pipeline is too long or bent too 
much,

 

or the lift is too high. 

2. The bottom valve, strainer or impeller 
is blocked locally. 
3. The impeller is seriously worn. 
4. The motor revolves reversely. 
5. The water level is low and close to the
suction lift limit of the Electric Pump. 

1. Shorten the pipeline, use the Electric Pump 
within its range of lift or make the bending of the 
pipeline gentle. 
2. Clear away sundries. 
3. Replace the impeller. 
4. Exchange any two phases of the three-phase 
power supply. 
5. Reduce the installation height of the Electric 
Pump.  

The Electric 
Pump stops 
running 
suddenly.

1. The protector is disconnected or the 
fuse is burnt. 
2. The impeller is blocked. 
3. The stator winding is burnt out.

1. Inspect whether the lift or supply voltage used 
complies with the relevant provisions and make 
an adjustment accordingly. 
2. Clear away  sundries. 
3. Re-insert the winding or carry out overhaul. 

The stator 
winding is burnt.

1. The supply voltage is too low. 
2. Water gets into the motor, which leads 
to  interturn or interphase short circuit. 
3. The impeller is blocked. 
4. The Electric Pump starts frequently. 
5. The Electric Pump works overload 
operation.

Do troubleshooting, disassemble the winding 
and re-insert the winding as per the concerned 
technical requirements as well as immerse and 
dry the insulating varnish or deliver the winding 
to the repair station for repair.

Содержание 2SGP

Страница 1: ...Vortex Type Micro Clean Water Pump Models SHF m CP m PRm SGA m PX m PUM 2SGP m SGT KSW PC CPH ZDK Mini type Clean water Centrifugal Electric Pump SERVICE MANUAL...

Страница 2: ...Precautions II Product Introduction III Operating Conditions IV Structure Diagram V Pump Wiring Diagram VI Installation Diagram VII Instructions for Installation VIII Maintenance IX Troubleshooting C...

Страница 3: ...ice properly and reliable grounding shall be provided at the place where the grounding sign of the Electric Pump or the cable lies the grounding conductor shall be connected to the terminal marked and...

Страница 4: ...inding insulation may lead to electrical leakage In winter when anti freezing measures are taken for a water pump hereunder no ammable material shall be used to cover the pump or its motor for freeze...

Страница 5: ...d as the static seal The Electric Pumps of the models hereunder with advantages such as small volume light weight compact structure and easy installation can be widely applied to irrigation and spray...

Страница 6: ...8 9 10 11 12 Rubber washer Capacitor Terminal box Nut of the terminal box Cable Cable sheath Rubber washer Terminal board Motor Housing Foot Hexagon socket head screw O ring 13 14 15 16 17 18 19 20 2...

Страница 7: ...ternal teeth lock washer 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Cross recessed pan headed self tapping screw Press plate for the cable Cable sheath Cable End cover Spring washer Hexagon headed bolt Fa...

Страница 8: ...g ring Key 1 2 3 4 5 6 7 8 9 10 11 Stator Cross recessed pan headed screw Terminal box cover Capacitor Press plate for the cable Cable sheath Cable Motor case Foot Hexagon bolt Mechanical seal 12 13 1...

Страница 9: ...16 17 18 Coupling Air faucet Dust cover Rotor Foot Stator motor case Rubber gasket Terminal box assembly Cross recessed small pan head screw External teeth lock washer Cross recessed ange face screw C...

Страница 10: ...1 2 3 4 5 6 7 8 9 10 11 12 13 14 I shaped hex nut Spring washer Flat washer Impeller Pump cover Mechanical seal Waterproof ring Framework oil seal O ring Coupling Spring washer Hexagon bolt Hexagon bo...

Страница 11: ...Copper bush Key Mechanical seal Waterproof ring 1 2 3 4 5 6 7 8 9 10 11 Coupling Rubber gasket Outlet joint Stator Motor Case Bottom of the terminal box Rubber washer Terminal box cover Nameplate Sel...

Страница 12: ...minal Grounding symbol Capacitor 1 2 3 4 5 6 7 8 9 10 11 12 13 Cross recessed small pan head screw Terminal box Nameplate Cable Cable locking head O ring Terminal Heat shrink tubing Press plate for th...

Страница 13: ...sed ange face screw 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Terminal board Cross recessed pan headed self tapping screw Press plate for the cable Coupling Rubber gasket Shaft sleeve Mechanical seal Cab...

Страница 14: ...Supply of Tap Water V Pump Wiring Diagram VI Installation Diagram Wiring of single phase pump Wiring of three phase pump Capacitor Yellow green Subline Secondary winding Main winding Common line Blac...

Страница 15: ...Farm Irrigation Water Supply by Water Tower on Roof and Downward Pressurization of Water Tower...

Страница 16: ...resistance limit to ensure that the pipe will not be deformed by heat for such deformation might make the pipe become broken and hence causing water leakage 3 After connecting the upper end of the inl...

Страница 17: ...P A B C OUTPUT A B C INTPUT FUSE AC 380V NOTICE Connected to the sewer line Prior to the initial use please fill the chamber of the Electric Pump with water and then power on it so as to avoid dry run...

Страница 18: ...over 5 minutes Where the Electric Pump operates with no water ow change inside the pump body resulting in the rise of the temperature and the pressure of the liquid in the pump body leakage may be ca...

Страница 19: ...in parts and components carry out rust proof treatment and keep it properly at a dry and well ventilated place NOTICE 1 Regularly inspect the insulation resistance between the enclosure and the windin...

Страница 20: ...eliable 2 Inspect the exibility of the bottom valve and the check valve and remove obstacles 3 Adjust or replace the seal 4 Check the water level and adjust the installation height of the Electric Pum...

Отзывы: