background image

Danger: Failure to observe the relevant rules will cause an electric shock.

Warning: Failure to observe the relevant rules will cause serious personal injuries.

Notice: Failure to observe the relevant rules will cause damage to the relevant product. 

It means that touch is prohibited.

It means the relevant rules shall be observed.

It means the prohibited actions. 

It is a symbol of ground wire in case of an electric shock. 

Thank you very much for choosing our products, and please read over the Operating Manual 

and  keep  it  properly  before  the  installation  and  use.  The  improper  usage  may  lead  to  personal 
injuries and property damages.

There  are  such  symbols  as  “Danger”,  “Notice”,  and  “Warning”  in  this  Operating  Manual, 

aiming to guarantee the correct use of the products involved and prevent hazards and damages. 
Please strictly follow them. 

I. Safety Precautions

Ground wire

Gas pipe

An Electric Pump involved hereunder shall be equipped with a leakage 
protection device properly and reliable grounding shall be provided at 
the place where the grounding sign of the Electric Pump or the cable lies 
(the grounding conductor shall be connected to the terminal marked) 
and simultaneously the connected power socket shall be reliably 
grounded as well. As shown in the below figure, the ground wire shall 
not be connected to a gas pipe, for it may result in an explosive; and the 
plug shall not be wetted and the power socket shall be located at a 
place which will not be affected by moisture. 

    Electrical connection shall be done 
by a holder of an electrician license 
in accordance with the relevant local 
code and safety standard. 

Statement: Any  hazard  or  loss  generated  by  any  of  the  following  circumstances  where  the 

content hereof is not observed shall not belong to the scope of the Company's quality warranty: 

•  Any  disassembly  or  repair  by  any  unqualified  person  or  any  usage  of  any  water  pump 

hereunder  independent  of  its  operating  conditions  makes  the  water  pump  unable  to  normally 
operate; 

• Any loss is caused by voltage or machinery or a chemical reason; or 
• Any environmental pollution caused by the use of any dangerous medium. 

Содержание 2SGP

Страница 1: ...Vortex Type Micro Clean Water Pump Models SHF m CP m PRm SGA m PX m PUM 2SGP m SGT KSW PC CPH ZDK Mini type Clean water Centrifugal Electric Pump SERVICE MANUAL...

Страница 2: ...Precautions II Product Introduction III Operating Conditions IV Structure Diagram V Pump Wiring Diagram VI Installation Diagram VII Instructions for Installation VIII Maintenance IX Troubleshooting C...

Страница 3: ...ice properly and reliable grounding shall be provided at the place where the grounding sign of the Electric Pump or the cable lies the grounding conductor shall be connected to the terminal marked and...

Страница 4: ...inding insulation may lead to electrical leakage In winter when anti freezing measures are taken for a water pump hereunder no ammable material shall be used to cover the pump or its motor for freeze...

Страница 5: ...d as the static seal The Electric Pumps of the models hereunder with advantages such as small volume light weight compact structure and easy installation can be widely applied to irrigation and spray...

Страница 6: ...8 9 10 11 12 Rubber washer Capacitor Terminal box Nut of the terminal box Cable Cable sheath Rubber washer Terminal board Motor Housing Foot Hexagon socket head screw O ring 13 14 15 16 17 18 19 20 2...

Страница 7: ...ternal teeth lock washer 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Cross recessed pan headed self tapping screw Press plate for the cable Cable sheath Cable End cover Spring washer Hexagon headed bolt Fa...

Страница 8: ...g ring Key 1 2 3 4 5 6 7 8 9 10 11 Stator Cross recessed pan headed screw Terminal box cover Capacitor Press plate for the cable Cable sheath Cable Motor case Foot Hexagon bolt Mechanical seal 12 13 1...

Страница 9: ...16 17 18 Coupling Air faucet Dust cover Rotor Foot Stator motor case Rubber gasket Terminal box assembly Cross recessed small pan head screw External teeth lock washer Cross recessed ange face screw C...

Страница 10: ...1 2 3 4 5 6 7 8 9 10 11 12 13 14 I shaped hex nut Spring washer Flat washer Impeller Pump cover Mechanical seal Waterproof ring Framework oil seal O ring Coupling Spring washer Hexagon bolt Hexagon bo...

Страница 11: ...Copper bush Key Mechanical seal Waterproof ring 1 2 3 4 5 6 7 8 9 10 11 Coupling Rubber gasket Outlet joint Stator Motor Case Bottom of the terminal box Rubber washer Terminal box cover Nameplate Sel...

Страница 12: ...minal Grounding symbol Capacitor 1 2 3 4 5 6 7 8 9 10 11 12 13 Cross recessed small pan head screw Terminal box Nameplate Cable Cable locking head O ring Terminal Heat shrink tubing Press plate for th...

Страница 13: ...sed ange face screw 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Terminal board Cross recessed pan headed self tapping screw Press plate for the cable Coupling Rubber gasket Shaft sleeve Mechanical seal Cab...

Страница 14: ...Supply of Tap Water V Pump Wiring Diagram VI Installation Diagram Wiring of single phase pump Wiring of three phase pump Capacitor Yellow green Subline Secondary winding Main winding Common line Blac...

Страница 15: ...Farm Irrigation Water Supply by Water Tower on Roof and Downward Pressurization of Water Tower...

Страница 16: ...resistance limit to ensure that the pipe will not be deformed by heat for such deformation might make the pipe become broken and hence causing water leakage 3 After connecting the upper end of the inl...

Страница 17: ...P A B C OUTPUT A B C INTPUT FUSE AC 380V NOTICE Connected to the sewer line Prior to the initial use please fill the chamber of the Electric Pump with water and then power on it so as to avoid dry run...

Страница 18: ...over 5 minutes Where the Electric Pump operates with no water ow change inside the pump body resulting in the rise of the temperature and the pressure of the liquid in the pump body leakage may be ca...

Страница 19: ...in parts and components carry out rust proof treatment and keep it properly at a dry and well ventilated place NOTICE 1 Regularly inspect the insulation resistance between the enclosure and the windin...

Страница 20: ...eliable 2 Inspect the exibility of the bottom valve and the check valve and remove obstacles 3 Adjust or replace the seal 4 Check the water level and adjust the installation height of the Electric Pum...

Отзывы: