19
Installation of the shifting cable
* For information on how to replace the inner cable, refer to the maintenance section.
Use a shifting cable with one inner cable drum.
OT-SP40 (4 mm dia.)
Shield cap
Shifting lever end
Cassette joint end
Note:
Make sure that the shield cap is at the shifting lever end.
Installing to the cassette joint
< In the case of CJ-NX10 / CJ-8S20 >
1.
Pass the inner cable through the OT-SP40 outer casing through the end with the plastic cap.
Aluminum cap
Plastic cap
(Lever side)
•
Cutting the outer casing
If cutting the outer casing, cut it near the end with the plastic
cap while the cap is still attached.
Plastic cap
Then make the cut end perfectly round and attach the plastic
cap.
2.
Set the REVOSHIFT lever / shifting lever to
1
.
REVOSHIFT
< REVOSHIFT Lever >
1
Set to
1
RAPIDFIRE Plus
< Shifting Lever >
Set to
1