SAFETY PRECAUTIONS 

To ensure safe and proper operation of the balance, observe the following precautions. 

• 

Do not use the balance in hazardous areas. 
This includes areas where the balance is expose to dust or flammable gases and 
liquids. 

• 

Use the AC adapter specified by Shimadzu. 
To prevent electric shock, never disassemble the AC adapter. 

The AC adapter is designed for indoor use.    Do not use the AC adapter in exterior 
environments or where it may be splashed by water. 

Ensure that the power supply voltage meets the indicated range of the AC adapter. 

• 

Handle the balance carefully. 
The balance is a precision instrument of solid design. 

• 

Do not connect peripheral devices other than those recommended by Shimadzu.

 

 

The balance may not operate properly if peripheral devices other than those 

specified in this manual are used.  The specifications for the RS-232C/AUX 
connector are described in Section 3.2 "Personal Computer - RS-232C". Connect 
the peripheral devices according to the methods described in this instruction 
manual. 

 

• 

DO NOT disassemble the balance, accessories, or peripheral unit. 

 

 

Содержание B252KS

Страница 1: ...M054 E115C SHIMADZU CORPORATION Kyoto JAPAN Instruction Manual For Medium Sized Electronic Balance BX K series BX32KS BX52KS BX12KH BX22KH BX32KH BW K series BW32KS BW52KS BW12KH BW22KH BW32KH...

Страница 2: ......

Страница 3: ...balance display Indicates the display change or action sequence performed by the balance after an operation has been initiated Refer to the recommended sections for further information on a specific...

Страница 4: ...e it may be splashed by water Ensure that the power supply voltage meets the indicated range of the AC adapter Handle the balance carefully The balance is a precision instrument of solid design Do not...

Страница 5: ...ntroduction 17 2 2 Procedure of Menu Item Selection 17 2 3 Menu Map 19 2 4 General Menu Operations 27 2 4 1Setting Numeric Values 27 2 4 2Setting a Decimal Point 27 2 4 3Menu Lock 27 2 4 4Last Menu Re...

Страница 6: ...e 47 2 10 1 Unit Registration Menu 47 2 10 2 Conversion 47 2 10 3 PieceCounting 48 2 10 4 Solid Specific Gravity Measurement 49 2 10 5 Liquid Specific Gravity Measurement 50 2 11 System Setting Menu 5...

Страница 7: ...sic Information 69 3 3 2Example of Use 70 3 4 Foot Switches 72 3 5 Hook for Below Balance Weighing 73 4 APPENDIX 74 4 1 Part List 74 4 1 1Standard Accessories and Maintenance Parts 74 4 1 2Options 74...

Страница 8: ...ion measurement functions and a unit conversion function Furthermore it is a high performance multi functional balance which can be used in a great variety of applications when connected to peripheral...

Страница 9: ...the internal weight Fix of the screw of the internal cover Name Appearance Notes Balance unit Pan Built in calibration mass Calibration weight stopper screw Calibration weight cover Calibration weigh...

Страница 10: ...hat both the left and right levers have been turned until they come to a stop KEY Connector RS 232C Connector DATA I O Connector DCIN Connector Calibration lever 2 places on the left and on the right...

Страница 11: ...he currently displayed Menu Map item No operation Changes the selected unit 4 Switches between the 1d and 10d display 5 Increases the numeric value of the blinking digit by 1 No operation Sends the di...

Страница 12: ...nction Memory symbol Indicates that Net Total Weighing is ON for the Application Measurement function Communication symbol Illuminates during communication to external equipment through the RS 232C or...

Страница 13: ...ve or flammable gasses dust wind vibration electromagnetic waves or magnetic fields direct sunlight extreme temperature or humidity rain or the possibility of being splashed with water Large capacity...

Страница 14: ...bubble in the level rests inside the red circle Check that the balance is steady when adjustment is complete Note Adjusting the level can be done with ease if all 4 level screws are at first grounded...

Страница 15: ...to the power source Note When using the optional battery pack special accessory connect the fully charged battery pack to the DC IN connector of the balance using the cable attached to the battery pac...

Страница 16: ...flow Refer to the following sections for more information on the Span Calibration procedure For BX K series balances refer to Section 2 5 2 Span Calibration Using the Built in Weight For BX series ba...

Страница 17: ...three seconds is displayed and the display returns to the original number of decimal places 1 7 Maintaining and Transporting the Balance 1 7 1 Cleaning the Balance Use a soft damp cloth containing a n...

Страница 18: ...ght The BW K series is equipped with a built in calibration weight Temperature coefficient of sensitivity H type 4ppm C S type 5ppm C Range of temperature compensation 10 to 30 C Common Specifications...

Страница 19: ...menu are set they are stored even if the balance is turned OFF or if the power is disconnected 2 2 Procedure of Menu Item Selection The menu of the BX W BW K balance consists of four levels 1 Press th...

Страница 20: ...eighing Environment Enters the menu related to the installation environment and general operation of the balance Application Enters the menu related to applications and printing Unit Enters the menu r...

Страница 21: ...bration type is displayed The possible displays are BW only BW only BX or BW BX or BW Press the key again to display the first menu level Press the key repeatedly to cycle through the items or press t...

Страница 22: ...EST Calibration check using the built in weight 2 blinking Sets I CAL Span calibration using the external weight 3 blinking Sets I TEST Calibration check using the external weight 4 blinking Executes...

Страница 23: ...Full Scale mode 11 blinking Target mode 12 Target value 13 Limit value 14 blinking Group mode 15 Upper threshold 16 Lower threshold 17 blinking Level mode 18 Upper threshold 19 Lower threshold 20 blin...

Страница 24: ...Stability detection band 1 count 27 2 count 28 4 count 29 8 count 30 16 count 31 32 count 32 64 count 33 blinking Tracking ON 34 OFF 35 and blinking Pretare with all lighting at start 36 blinking Stop...

Страница 25: ...value 44 at value 0 and value 45 Continuous Output 46 Stability with GO 47 blinking Zero Range 48 blinking Peak Holding On Off 49 blinking Interval Timer PRINT Time interval 50 symbol blinking Memory...

Страница 26: ...me Liquid density DL 61 Lb Pound 61a Oz Ounce 61b Ozt Troy Ounce 61c Hong Kong s tael 61d Singapore tael 61e Taiwanese tael 61f Malaysia tael 61g Chinese tael 61h dwt Pennyweight 61i GN Grain 61j m Me...

Страница 27: ...nking Display during standby setting Time 65 Data 66 No display 67 blinking Report and control setting CAL report creating Create 68 Not create 69 Balance ID 70 PCAL Password 71 blinking Menu reset to...

Страница 28: ...S type 80 blinking Baud Rate Bits sec 300 bps 81 600 bps 82 1200 bps 83 2400 bps 84 4800 bps 85 9600 bps 86 19200 bps 87 38400 bps 88 blinking Parity bit length None 8 bits 89 Odd 7 bits 90 Even 7 bit...

Страница 29: ...the value Press the key to stop numeric entry is displayed briefly and the display returns to the menu one level up 2 4 2 Setting a Decimal Point A decimal point is only used when setting units for s...

Страница 30: ...indicate that the menu lock has been turned off 2 4 4 Last Menu Recall This function is convenient when an application requires frequent changes to a specific Menu Map item During mass display or men...

Страница 31: ...6 4 Press the key to display means 5 Press the key again is displayed to indicate menu reset completion 6 Press the key several times or hold it for approximately 3 seconds to return to the mass displ...

Страница 32: ...3 specific preset times during each day The user selects the times PCAL Procedure to calibrate the built in calibration mass to an external calibration mass standard The PCAL procedure is password pro...

Страница 33: ...empty 2 Press the key once is displayed If is not displayed return to mass display and select Menu Map item 2 3 Press the key When is displayed and the stability mark illuminates on the left in the d...

Страница 34: ...rnal Weights 1 Verify that the balance is in mass display and unload the sample from the pan 2 Press the key once is displayed If is not displayed return to mass display and select Menu Map item 3 3 P...

Страница 35: ...ion mass and press the key The zero display blinks 5 Unload the weight from the pan and press the key The display changes to the xxx display xxx indicates a numeric value 6 To change the value to zero...

Страница 36: ...s the key The default password is 9999 set at shipment or upon menu reset 4 After is displayed the value of the standard weight to be loaded blinks Load the standard mass displayed and press the key 5...

Страница 37: ...cimal point is invisible in the value setting display Determine its position based on the resolution of the balance For example if the balance s minimum display is 0 01g 150g must be set by inputting...

Страница 38: ...er threshold value which corresponds to the lower triangle Note Determination as follows Display Sample weight HI Sample weight GO Sample weight LO 2 7 5 Level Mode Use this mode for classification ba...

Страница 39: ...mal environment Averaging is fixed and does not change dynamically as in Menu Map item 25 Environment Averaging VIBRation Use this mode when the balance is used in a location where there are large vib...

Страница 40: ...he process of drop addition or liquid evaporation 2 8 5 Pretaring Value This function is used to weigh the mass of a sample packed in a container such as a bottle or bag without opening the container...

Страница 41: ...ey to proceed to the mass display Menu Map item 38 After the whole lighting display has appeared for approximately 0 5 sec the display automatically proceeds to the mass display 2 8 7 Taring Printing...

Страница 42: ...76 Once the key is pressed data is not output until the and symbol has illuminated and the balance is stable Data is output only after the stability symbol is lit...

Страница 43: ...the Application Measurement function cannot be selected while PCS or specific gravity units are displayed 2 9 2 Zero Range The Zero Range value is used in the Application Measurement function as a re...

Страница 44: ...the sample when the value displayed is within the Zero Range When the stability symbol has illuminated and the positive displayed value is more than 5 times the Zero Range data is automatically output...

Страница 45: ...symbol ha illuminated data is output again Menu Map item 46 on continue By pressing the key while the and symbols are lit the symbol goes out the symbol lights and the displayed data is continuously o...

Страница 46: ...times or more of Zero Range from the display within Zero Range Usually the peak value is easily measured by setting to 23 Depending on the weighting conditions and the sample type this setting may not...

Страница 47: ...s used to weigh a large number of individual samples The Auto Memory and Zeroing symbol is illuminated when this function is active 1 Load the weighing vessel and press the key in the Auto Memory and...

Страница 48: ...ess than 10 times the Zero Range automatic zeroing occurs Any residue remaining on the pan excrement or fur is automatically canceled and zeroing occurs If zeroing does not occur increase the value of...

Страница 49: ...value multiplier multiplied by the gram g weight of the unit To register Functional Units set the constant to something other than 0 Setting the constant to 0 turns the function off For the unit name...

Страница 50: ...is pcs Press the key when the display is equivalent to the number of loaded pieces Example If 50pcs are loaded press the key when pcs is displayed This determines the unit weight or average weight per...

Страница 51: ...d the sample on the balance pan or in the hanging pan in air 6 After the stability symbol illuminates press the key may be displayed but does not indicate a malfunction 7 Load the sample on the hangin...

Страница 52: ...l d is displayed 4 Press the key 5 Load the reference weight on the pan of the balance 6 After the stability symbol is illuminated press the key may be displayed but does not indicate a malfunction 7...

Страница 53: ...set after setting the time the second value will be incorrect It is important to set the date first and then the time or to correct the seconds value using the second correcting function described lat...

Страница 54: ...r on the main body of the balance The user can add a four digit ID number to the calibration report Set with Menu Map item 70 Use a 4 digit number from to 2 11 4 3 PCAL Password Enter a 4 digit number...

Страница 55: ...alance output is initiated Menu Map item 75 Hardware handshaking is performed When DTR is OFF the output from the balance is retained When DTR is ON the output from the balance is initiated Menu Map i...

Страница 56: ...7 Delimiter The delimiter is used to separate individual pieces of data or commands Set the delimiter as follows Menu Map item 94 Set to CR 0DH Menu Map item 95 Set to LF 0AH Menu Map item 96 Set to C...

Страница 57: ...ct the DATA I O connector of the balance to the EP 60A using the attached cable of the EP 60A 4 First turn ON the power to the balance then to the EP 60A 3 2 Personal Computer RS 232C 3 2 1 Connecting...

Страница 58: ...he compatible machine Note indicates space code and delimiter indicates delimiter code 1 For the measured value First character Minus Non minus space 2nd to 11th characters Numeric values or are flush...

Страница 59: ...TARE 0 00 CR example of the second decimal place Clears cancels the Pretare value Note Number of digits decimal point position of decimal point of the numeral transmitted succeeding to are the same a...

Страница 60: ...nd or and the delimiter An unprocessed echo back command is not left in the receiving buffer of the balance N 30 Example 8 ABCDEFG12345 CR After receiving this command the balance outputs ABCDEFG12345...

Страница 61: ...ately 3 seconds RECALC Equivalent to the RECALC key of the AKB 301Application Keyboard C Equivalent to the C key of the AKB 301 Application Keyboard iii Commands related to Application Measurement PEA...

Страница 62: ...e in Group mode G LO Readout of upper limit set value in Group mode L LO Readout of lower limit set value in Level mode L UP Readout of upper limit set value in Level mode UW Readout of unit weight se...

Страница 63: ...iece Corresponds to numeral keys of AKB 301 Application Keyboard ID Sets ID PASSSET Sets PCAL password PASS Inputs PCAL password vii Commands of special functions CAL Enters Span Calibration mode C18...

Страница 64: ...76 Z Zero setting same as immediate taring 6 Compatible command with Sartorius Electronic Balances ESC P One time output ESC T Taring Note ESC indicates escape code 1BH...

Страница 65: ...lance 4 Connect the personal computer to the balance with the RS 232C cable 5 Turn ON the power to the personal computer only and start Windows 6 Click Start choose Settings and Control Panel then sel...

Страница 66: ...Cs without any problems currently or in the future Shimadzu is not liable for any direct or indirect problems caused by this function It is recommended that important data or programs on your PC be ba...

Страница 67: ...t a weight value i e error code or time The unit designation is not transmitted This function may operate incorrectly depending on the settings of various lock keys of the keyboard such as the NUMLOCK...

Страница 68: ...wer case j This command is valid only one time after turning the power ON Respective balances automatically enter the Multi Connection mode and the mass is displayed On this process the name smaller t...

Страница 69: ...nd commands exist on the system at the same time the balance may not operate normally For example multiple data may exist simultaneously on the system when using multiple balances in the Application M...

Страница 70: ...threshold value of graphic display comparator as if you were operating a pocket calculator Use of the AKB 301 Application Keyboard is recommended for performing piece count and pass or failure judgme...

Страница 71: ...graphic display or sets value Displays value of graphic display or displays value TARGET key 4 For target display sets value For target display displays value g PCS key Recalculates the weight with r...

Страница 72: ...nd keys to set the desired graphic display mode 1 Target display mode Setting the target value Example Press the numeric keys for 10000 and then the TARGET key The Target value is set to 10000 Setting...

Страница 73: ...tored unit weight The display may not be 25 pieces 3 Press the numeric keys for 25 and then the g PCS key 4 Piece count is now displayed in the new unit weight Recalculating the Unit Weight To recalcu...

Страница 74: ...le To input 123 456 Enter 123 456 and press the PRINT key Setting a Numeric Menu Value Use the number keys of the AKB to enter numeric values during menu selection Numbers are set sequentially startin...

Страница 75: ...rews into the screw holes for the transportation screws on the bottom of the balance 2 places as shown in the diagram on the right until the screws cannot be tightened anymore Note Be careful to ensur...

Страница 76: ...4986 Dot matrix type EP 60A Electronic Printer 321 42008 10 Thermal type RS 232C cable 25P 9S 1 5m 321 60117 01 For PC AT DOS V RS 232C cable 25P 25P 1 5m 321 60116 01 For some NEC PC 98 models Standa...

Страница 77: ...73 Three triangle symbols display 61f U SporE TL S pore 0 0264554 61g U tiwAn TL Taiwan 0 0266667 A triangle symbol displays 61h U tiwAn TL Taiwan 0 0266667 Three triangle symbols display 61i U mal TL...

Страница 78: ...ank 9 NC Blank 10 NC Blank 11 NC Blank 12 NC Blank 13 NC Blank 14 NC Blank 15 NC Blank 16 NC Blank 17 NC Blank 18 NC Blank 19 NC Blank 20 DTR Handshake receiving 21 NC Blank 22 NC Blank 23 NC Blank 24...

Страница 79: ...re stored Reset by power failure Built in weight is moving Wait All numerals blinking Place the displayed calibration mass 4 4 2 Error Display Error display Description Countermeasure The load on the...

Страница 80: ...numeric value Review the numeric value and decimal places Necessary conditions and numeric values are not set Check graphic display mode key was pressed during menu lock Release menu lock Mode for ope...

Отзывы: