background image

I5500 Owner's Manual (2003-Current Models) 

**TROUBLESHOOTING NOTE: Some scale owners (especially with the i2600) have noted that their 
scale will give a MUCH more accurate calibration if calibration is performed as quickly as possible (not 
pausing between steps).

 This is especially true in the step after you have placed the calibration weight 

on the tray. If your scale is acting inaccurate after calibration, please try recalibrating 'as quickly as 
possible'.  

Low Batteries, bad battery connections & Faulty AC Adaptors are the #1 cause of scale malfunction 
and inaccuracy

! We test all of our scale returns from consumers. Fully 60% of consumer returns are 

battery related problems. This sounds silly but it's true! A scale will perform slowly, or read inaccurately 
when it has low batteries. Please replace the batteries often (and only use good quality batteries). We 
include good quality batteries with all of our scales but batteries can run low in storage. If your scale 
simply won't turn on while on Battery power, this is often caused by loose battery connections. Battery 
prongs (terminals) are made of metal. They must be making good contact with your batteries in order 
for the scale to power on. You can use a paperclip to slightly bend the battery prongs to make them 
have a better connection. Also some poorly designed batteries have recessed or partially obstructed 
battery terminals. This may cause your prongs to be touching the plastic housing of the battery instead 
of the metal battery terminal. A Faulty AC adaptor can cause your scale to act unstable with numbers 
"jumping" all around. Please test your scale with a good set of batteries (instead of the AC adaptor) to 
determine if perhaps the AC adaptor is faulty.  

Due to the SS tray of the iBalance, this model is especially prone to being charged with Static Electricity. 
Please discharge any static electricity if you think your scale is acting unstable.  

SAFETY PRECAUTIONS

 

All safety messages are identified by the words 

warning

 and 

caution

. These words mean the following:  

Warning

 Important information to alert you to a situation that might cause serious injury and damage to 

your property if instructions are not followed.  

Caution

 

Important information that tells how to prevent 
damage to the equipment.  

When using the i500/i1200, the following safety 
precautions should always be followed.  

Warning:

 Use only the correct AC adaptor with the 

scale. Other adaptors may cause permanent electrical 
damage. The i2600 uses an adaptor that is different 
from the i500 and i1200. For reference, the i2600 
adaptor is pictured here:  

Содержание I5500

Страница 1: ...on You can use a paperclip to slightly bend the battery prongs to make them have a better connection Also some poorly designed batteries have recessed or partially obstructed battery terminals This may cause your prongs to be touching the plastic housing of the battery instead of the metal battery terminal A Faulty AC adaptor can cause your scale to act unstable with numbers jumping all around Ple...

Страница 2: ... 24 Units in one box 48 48 22 cm3 Operating Temperature 0 40c 32 104f Power source 6 AA Size Batteries or AC DC Adapter 9V 100mA optional CALIBRATION When to calibrate calibration is RARELY required Calibration may be required when the scale is first set up for use or if the scale is moved to a different altitude or gravitation This is necessary because the weight of a mass in one location is not ...

Страница 3: ...a given number of samples of an item on the pan the Sample Size should be either 10 20 50 or 100 pieces The weight of these samples will show on the display 4 Press the SET key several times to put the scale in PCS mode the indicator should be on pcs 5 Select the sample size the same as you chose above by pressing the PCS key press it as many times as necessary to put it in the correct sample size...

Страница 4: ...tor Indicates when the scale zero is correct Weighing unit Stable indicator Indicates when the reading is stable Low battery indicator PREPARATION Installing batteries Connecting the AC adaptor Remove the battery compartment and insert six Dry batteries R6P LR6 AA size into the battery compartment Use extreme care that the polarities plus and minus are correct Plug the AC adapter to the AC adapter...

Страница 5: ...yed and press ZERO Place the objects to be weighed in the container When the reading becomes stable the stable indicator is displayed FUNCTION SETTINGS 2003 Current models only 1 Enter function setting mode Press ON OFF to turn the power off Press Mode first then press ON OFF while keeping Mode pressed the display will show b_on arrow direct to light this means enter the selection of auto backligh...

Отзывы: