LED DISPLAY
INDICATES
FAULT
Troubleshooting
Drive Errors
Drive errors, or “fatal errors” that stop each action immediately and in‑
volve the stepper motor. If a “fatal error” occurs, your current label may
not be applied properly.
Stepper driver errors can be: over‑temperatures (of motor or power am‑
plifier), short circuit (between two motor phases or between motor phase
against PE), over‑voltage, low‑voltage, rotation monitoring (RM) fault,
power amplifier deactivation, or motor current free. Refer to the LED
status display of the stepper motor drive inside the electrical cabinet (see
Figure 6‑1).
Figure 6-1. Stepper Drive Motor Fault Display
Labeling Errors
Labeling errors can be caused by missing labels on the label web, label
paper in the gaps, wrongly adjusted or defective label sensor or an empty
supply roll.