70
71
Chapter 5 Operator Interface
AIR ASSIST DWELL
Used to help push the label further onto the tamp pad.
Larger number to keep the air assist valve activated for more time.
Smaller number to keep the air assist valve activated for less time.
a
Sets how long air assist valve stays activated to blow the label up
onto the tamp pad.
a
Min Value: 0 (ms); Max Value: 99999 (ms)
a
Default value: 150
Parameter Menu - Blow
BLOW DELAY
Sets delay between sensing of product and activation of blow assem‑
bly.
Larger number to position label closer to trailing edge of product.
Smaller number to position label closer to leading edge of product.
a
Min Value: 0 (ms); Max Value: 99999 (ms)
a
Default value: 0
BLOW DWELL
Sets dwell time for the blow assembly.
Larger number to extend the time the blow assembly is activated.
Smaller number to reduce the time the blow assembly is activated.
a
When a blow assembly is installed, VACUUM DWELL affects how
firmly the label is affixed to the product.
a
Min Value: 0 (ms); Max Value: 99999 (ms)
a
Default value: 100
+
AIR ASSIST DWELL
+00000 [ms]
PARAMETER - TAMP
-EXIT
ENTER
SCRUP SCRDN
+
BLOW DELAY
+00000 [ms]
PARAMETER - BLOW
-EXIT
ENTER
SCRUP SCRDN
+
BLOW DWELL
+00000 [ms]
PARAMETER - BLOW
-EXIT
ENTER
SCRUP SCRDN
Содержание L500A V2
Страница 12: ...L500A V2 High Speed Labeler Manual 12 Notes ...
Страница 14: ...L500A V2 High Speed Labeler Manual 14 Notes ...
Страница 22: ...L500A V2 High Speed Labeler Manual 22 Notes ...
Страница 50: ...L500A V2 High Speed Labeler Manual 50 Notes ...
Страница 80: ...L500A V2 High Speed Labeler Manual 80 Notes ...
Страница 84: ...L500A V2 High Speed Labeler Manual 84 Notes ...
Страница 89: ...89 Appendix Figure 8 1 Wiring Diagram 8 ...
Страница 90: ...L500A V2 High Speed Labeler Manual 90 Figure 8 2 Wiring Diagram ...