Chapter 5 Operator Interface
RATIO ADJUST
The Ratio Adjust is used to override the gear factor set by the gear nu‑
merator and gear denominator (thereby overriding encoder values). It
only works in synchronous dispensing mode.
a
Min Value: 50 (%); Max Value: 150 (%)
a
Default value: 100 (This means 100%. To decrease, the value must
be less than 100 - such as 90%, or 80%.)
Parameter Menu - Tamp
TAMP DELAY
Sets delay between sensing of product and activation of tamp assem‑
bly.
Larger number to position label closer to trailing edge of product.
Smaller number to position label closer to leading edge of product.
a
Min Value: 0 (ms); Max Value: 99999 (ms)
a
Default value: 0
TAMP DWELL
Sets dwell time for the tamp assembly.
Larger number to extend the time the tamp is extended.
Smaller number to reduce the time the tamp is extended.
a
Min Value: 0 (ms); Max Value: 99999 (ms)
a
Default value: 100
+
RATIO ADJUST
+100 [%]
PARAMETER - WIPE
-EXIT
ENTER
SCRUP SCRDN
+
TAMP DELAY
+00000 [ms]
PARAMETER - TAMP
-EXIT
ENTER
SCRUP SCRDN
+
TAMP DWELL
+00000 [ms]
PARAMETER - TAMP
-EXIT
ENTER
SCRUP SCRDN
Содержание L500A V2
Страница 12: ...L500A V2 High Speed Labeler Manual 12 Notes ...
Страница 14: ...L500A V2 High Speed Labeler Manual 14 Notes ...
Страница 22: ...L500A V2 High Speed Labeler Manual 22 Notes ...
Страница 50: ...L500A V2 High Speed Labeler Manual 50 Notes ...
Страница 80: ...L500A V2 High Speed Labeler Manual 80 Notes ...
Страница 84: ...L500A V2 High Speed Labeler Manual 84 Notes ...
Страница 89: ...89 Appendix Figure 8 1 Wiring Diagram 8 ...
Страница 90: ...L500A V2 High Speed Labeler Manual 90 Figure 8 2 Wiring Diagram ...