L500A V2 High Speed Labeler Manual
72
73
VACUUM DELAY
Delays activation of the vacuum that pulls the label onto the blow as‑
sembly.
Larger number to turn the vacuum on later.
Smaller number to turn the vacuum on earlier.
a
Delay starts when blow assembly gets to home position. If the
leading edge of the label does not arrive all the way to the edge of
the peeler plate, increase this setting.
a
Min Value: 0 (ms); Max Value: 99999 (ms)
a
Default value: 0
VACUUM DWELL
Sets how long vacuum stays activated as the blow assembly is applying
the label.
Larger number to keep the vacuum activated for more time.
Smaller number to keep the vacuum activated for less time.
a
Min Value: 0 (ms); Max Value: 99999 (ms)
a
Default value: 0
AIR ASSIST DELAY
Used to smooth the transition of the label from the peeler tip to the blow
assembly. See also VACUUM DELAY screen.
Larger number to turn the air assist valve on later.
Smaller number to turn the air assist valve on earlier.
a
Delays activation of the air assist valve.
a
Min Value: 0 (ms); Max Value: 99999 (ms)
a
Default value: 0
+
VACUUM OFF DWELL
+00000 [ms]
PARAMETER - TAMP
-EXIT
ENTER
SCRUP SCRDN
+
AIR ASSIST DELAY
+00000 [ms]
PARAMETER - TAMP
-EXIT
ENTER
SCRUP SCRDN
+
VACUUM DELAY
+00000 [ms]
PARAMETER - TAMP
-EXIT
ENTER
SCRUP SCRDN
Содержание L500A V2
Страница 12: ...L500A V2 High Speed Labeler Manual 12 Notes ...
Страница 14: ...L500A V2 High Speed Labeler Manual 14 Notes ...
Страница 22: ...L500A V2 High Speed Labeler Manual 22 Notes ...
Страница 50: ...L500A V2 High Speed Labeler Manual 50 Notes ...
Страница 80: ...L500A V2 High Speed Labeler Manual 80 Notes ...
Страница 84: ...L500A V2 High Speed Labeler Manual 84 Notes ...
Страница 89: ...89 Appendix Figure 8 1 Wiring Diagram 8 ...
Страница 90: ...L500A V2 High Speed Labeler Manual 90 Figure 8 2 Wiring Diagram ...