WARNING! 

Before installing and commissioning, please read these instructions 

1. GENERAL 

Commissioning and operation of the device can be made only after a careful reading of this handbook. 

Due to the continuous development of technical equipment, some of its functions can be modified and operation may differ in detail from the 
description in the manual. This is not a device error, but the result of continuous progress and modification work unit.

Damage from improper handling results in a loss of warranty. Any alteration of the rectifier are prohibited and void the warranty.

2. SAFETY 

Staff operating the device should have the necessary qualifications entitling them to carry out welding work: 

should have the competence in the field of electric welder MMA welding and gas-shielded, 

know the rules of safety during the operation of the power they are welding equipment and auxiliary equipment powered by electricity, 

know the safety rules when handling and installation of the cylinder of compressed gas (argon) 

know the contents of this manual and use the device for its intended purpose. 

WARNING 

Welding may endanger the safety of the operator and other persons in the vicinity. Therefore, when welding special precautions must be 
taken. Prior to welding, refer to the applicable health and safety regulations in the workplace. During electric welding MMA and TIG has the 
following hazards:

ELECTRIC SHOCK 

ARC NEGATIVE IMPACT ON HUMAN EYES AND SKIN 

PAIRS AND GAS POISONING 

BURNS 

EXPLOSION AND FIRE HAZARDS 

NOISE 

Prevention of electric shock: 

a device connected to a technically efficient electrical system to the proper security and effectiveness of neutral (additional fire protection); 
Check and properly connect to the network and other devices in the workplace welder,

current leads off with the mounted unit, 

It does not simultaneously touch the non-insulated part of the electrode holder, the electrode and the workpiece in the device housing, 

Do not use the handles and load wires with damaged insulation, 

under special hazard of electric shock (work in environments with high humidity and closed tanks) to work with the helper supporting the work of 
the welder and watchful over the safety, use gloves and clothing with good insulation properties, 

if you notice any irregularities, please contact the competent people to remove them, 

It is forbidden to operate the device with the covers removed. 

Preventing negative effects of electric arc on human skin and eyes: 

Use protective clothing (gloves, lab coat, shoes, leather) 

Use protective shields or helmets with properly matched filter, 

Use protective curtains of non-combustible materials, and properly selected colors wall absorbing the harmful radiation. 

Содержание DIGITIG 200AC / DC MULTIPRO

Страница 1: ...V1 2 18 08 23 USER MANUAL WELDING RECTIFIER Inverter DIGITIG 200AC DC MULTIPRO...

Страница 2: ...lding refer to the applicable health and safety regulations in the workplace During electric welding MMA and TIG has the following hazards ELECTRIC SHOCK ARC NEGATIVE IMPACT ON HUMAN EYES AND SKIN PAI...

Страница 3: ...ger in a place that allows its easy handling Persons operating welder should have the power to electric welding electrode welding and TIG know and comply with applicable health and safety regulations...

Страница 4: ...60 TIG 200 A 60 Rated voltage of no load condition 67 V Maximum current consumption MMA 26 6 A 19 6 A TIG network security 25 And Weight without accessories 17 kg dimensions 480 x 200 x 330 mm Level...

Страница 5: ...h voltage fluctuations in the mains to 10 6 CONNECTION TO THE MAINS 1 A device to be used only in a single phase three wire with earthed neutral 2 The inverter units DIGITIG 200AC DC MULTIPRO are adap...

Страница 6: ...e socket 3 and the gas connection socket connectors 2 Gas conduit from the regulator lead and attach to the gas nozzle 9 located on the rear wall of the housing The positive pole of the source 5 conne...

Страница 7: ...2V And MMA 19 6 1max And MMA 13A 1eff TECWELD Peter Polak 41 943 Piekary Sl Ul Emerald 21 3 6 Sherman ACDC TIG 200P Model DIGITIG 200ACDC MULTIPRO ACDC TIG 200P Model DIGITIG 200ACDC MULTIPRO ACDC TIG...

Страница 8: ...n button welding methods The button is used to select the welding method The choice of method is signaled by lighting up the symbol MMA welding with covered electrode MMA LIFT welding the tungsten ele...

Страница 9: ...n again within 10 seconds will save the current within 10 seconds will save the current setting the currently selected number If the 10 seconds will not happen again the machine will return to the mai...

Страница 10: ...with thermal a circuit breaker When the temperature is too high welding machines safety disconnects the welding current LED OT lights up and the display shows the error code E00 After falling temperat...

Страница 11: ...er supply pipe gas cylinder przedwyp ywu time should be longer Range 0 1 15s Initial current And Start current appearing in the circuit by pressing the button in the handle grip The higher initial cur...

Страница 12: ...a narrower and deeper weld penetration while reducing the thermal load of the tungsten electrode Increasing the balance will introduce less heat to the material to provide improved cleaning wide and...

Страница 13: ...s t1 t2 The arc the welding current increases from the minimum value to the set value t1 t2 The arc the welding current increases from the minimum value to the set value t1 t2 The arc the welding curr...

Страница 14: ...rrent crater t5 t6 Current crater t5 t6 Current crater t6 t6 Release the handle Arc is extinguished the shielding gas flows t7 t7 The solenoid valve closes the gas flow the completion of welding 11 Be...

Страница 15: ...Operation of the device DIGITIG 200AC DC MULTIPRO should take place in an atmosphere free of corrosive components and dusty Do not place the device in dusty near the working grinders etc Dust and pol...

Страница 16: ...ion the state security the operation of the cooling system Damage resulting from the welding operation in unsuitable conditions and failure of recommendations for maintenance are not covered by warran...

Страница 17: ...the European Union for used electrical and electronic equipment must be used methods of utilization In Poland in accordance with the provisions of the Act of July 1 2005 Waste electrical and electroni...

Страница 18: ...2004 108 EC II RoHS Directive 2011 65 EU and is compliant with the following standards BS EN 60974 1 2013 04 Arc welding equipment Part 1 Welding power sources BS EN 60974 1 2013 04 Arc welding equip...

Отзывы: