Detailed Function Description
63
P0-095
PLC Dec time0
Setting range:0.1
~
3200.0s
Factory value:15.0s
P0-096
PLC Acc time 1
Setting range:0.1
~
3200.0s
Factory value:15.0s
P0-097
PLC Dec time 1
Setting range:0.1
~
3200.0s
Factory value:15.0s
P0-098
PLC Acc time 2
Setting range:0.1
~
3200.0s
Factory value:15.0s
P0-099
PLC Dec time 2
Setting range:0.1
~
3200.0s
Factory value:15.0s
P0-100
PLC Acc time 3
Setting range:0.1
~
3200.0s
Factory value:15.0s
P0-101
PLC Dec time 3
Setting range:0.1
~
3200.0s
Factory value:15.0s
Set per step PLC Acc/Dec time.
P0-102
PLC run direction
Setting
range:0~65535
Factory
value:0
setting
Set the PLC running directions , need binary switching. A binary
number of 16-bit, the lowest is the BIT0, the highest is the BIT15.
BIT0 means that PLC 0
th
-step running direction. When BIT0
=
0
,
the 0
th
-step running direction is positive; when BIT0
=
1
,
the
0
th
-step running direction is opposite.
……
Содержание DK00 Series
Страница 1: ...DK00 Series Inverter User Manual V1 3...
Страница 3: ...2 3 Installation dimensions of inverter 12 2 4 Installation dimension of keyboard 14 3 wiring 15...
Страница 5: ...4 2 4 Fault Alarm Reset 26 4 2 5 Keyboard digital setting modify...
Страница 7: ...5 1 11 Serial Communication Settings 56...
Страница 9: ...7 Maintenance 73 7 1 Inspect the inverter periodically73...
Страница 11: ...9 3 Examples of MODBUS Information 100...
Страница 13: ...Chart Index 109...
Страница 25: ...1 2 Installation 2 3 Installation dimensions of inverter Chart 2 2 External dimension...
Страница 85: ...72 Fault and trouble shooting...
Страница 126: ...Chart Index 113 Chart 9 9 Error codes of serial communication 107...
Страница 127: ...In order to improve our products constantly we remain the power of designs modified 3 8 2010...