IMPORTANT SAFETY INSTRUCTIONS:

WHEN USING ELECTRICAL PRODUCTS, ESPECIALLY WHEN CHILDREN ARE 
PRESENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED, 
INCLUDING THE FOLLOWING:

READ ALL INSTRUCTIONS BEFORE USING

DANGER

 

– TO REDUCE THE RISK OF ELECTRIC SHOCK:

• Always unplug the air cleaner from the electrical outlet immediately after using and  
  before cleaning.
• Keep cord away from heated surfaces
• Always place the air cleaner on a firm, level surface.
• Always place the air cleaner at least six (6) inches away from walls and three (3) feet  
  from heat sources such as stoves, radiators, or heaters.
• DO NOT operate where aerosol (spray) products are being used or where oxygen is  
  being administered.
• DO NOT reach for an appliance that has fallen into water. Unplug it immediately.
• DO NOT place or store appliance where it can fall or be pulled into a tub or sink.
• DO NOT place in or drop into water or other liquid.
• Keep dry - DO NOT operate in a wet or moist condition.
• Check your air cleaner cord and plug connections. Faulty wall outlet connections or  
  loose plugs can cause the outlet or plug to overheat. Be sure the plug fits tight in the  
  outlet.

WARNING

 

-

 TO REDUCE THE RISK OF BURNS, FIRE, ELECTRIC 

SHOCK OR INJURY TO PERSONS:
•  Extreme caution is necessary when any air cleaner is used by or near children or 

invalids  and whenever the air cleaner is left operating and unattended.

•  Always unplug the air cleaner when not in use.
•  Do not operate the air cleaner with a damaged cord or plug, or after the air cleaner 

malfunctions, has been dropped or damaged in any manner. Discard the air 
cleaner or return to SI Products Consumer Relations for examination, electrical or 
mechanical adjustment, or repair.

• This air cleaner is not intended for use in bathroom, laundry areas and similar moist 

indoor locations. Never locate air cleaner where it may fall into a bathtub or other 
water container.

•  Do not run cord under carpeting. Do not cover cord with throw rugs, runners or 

similar coverings. Do not route cord under furniture or appliances.  Arrange cord 
away from traffic areas where it can be tripped over.

• To disconnect the air cleaner, first turn controls to the OFF position, then remove 

plug from outlet. 

• Do not tilt or move the air cleaner while it is in operation.  Shut off and remove plug 

from outlet before moving.

• Do not insert or allow foreign objects to enter any ventilation or exhaust opening as 

this may cause an electric shock or fire, or damage the air cleaner.

• To prevent a possible fire, do not block air intakes or exhaust in any manner. Do not 

use on soft surface, like a bed, where openings may become blocked.

• Use this air cleaner only for its intended use as described in this manual.  Any other 

use not recommended by the manufacturer may cause fire, electric shock, or injury 
to persons.

• DO NOT use outdoors.

Содержание EVSI-AR60

Страница 1: ...icaciones o adaptación para habilitar su funcionamiento en cualquier país que no sea aquél para el que fue diseñado fabricado aprobado y o autorizado o la reparación de productos dañados por estas modificaciones no están cubiertos bajo esta garantía LA GARANTÍA AQUÍ ESTABLECIDA SERÁ LA ÚNICA Y EXCLUSIVA GARANTÍA NO HABRÁ NINGUNA OTRA GARANTÍA EXPRESA NI IMPLÍCITA INCLUYENDO NINGUNA GARANTÍA DE COM...

Страница 2: ...alids and whenever the air cleaner is left operating and unattended Always unplug the air cleaner when not in use Do not operate the air cleaner with a damaged cord or plug or after the air cleaner malfunctions has been dropped or damaged in any manner Discard the air cleaner or return to SI Products Consumer Relations for examination electrical or mechanical adjustment or repair This air cleaner ...

Страница 3: ... REFERENCE Technical Specifications Main Features on the Sharper Image Tower Air Cleaner Input voltage 120 V Rated Frequency 60 HZ Power 60 Watts Weight 12 5 lbs Noise Level 60 dB Unit Height 28 Control Panel Main Unit HEPA Filters Rear Grill Plate ...

Страница 4: ...om the unit 3 The HEPA filters will be resting inside the unit Make sure that the filters are firmly seated inside of the unit Fig 1 Fig 2 Fig 3 NOTE This appliance has a polarized plug one blade is wider than the other To reduce the risk of shock this plug is intended to fit only one way in a polarized outlet If the plug does not fit fully in the outlet reverse the plug If it still does not fit c...

Страница 5: ...ord into a standard AC outlet NOTE Unit will not operate unless filters and grill are properly installed 1 On Off and Speed Settings To turn the air cleaner on press the ON OFF button on the control panel When the air cleaner is on the LED light in the ON OFF button on the control panel will be lit and the air cleaner will start to operate on LOW speed Once the air cleaner is ON press the button t...

Страница 6: ...place the metal UV bulb cover 7 Replace the rear grill NOTE UV C bulb contain Mercury Hg Dispose of according to Local State and Federal Law www lamprecycle org Clean Filter Indicator The air cleaner is equipped with a CLEAN FILTER indicator to let the user know when it is time to clean the HEPA filter about every 480 hours of use When the HEPA filter is ready to be cleaned the LED CLEAN FILTER in...

Страница 7: ...en surface Troubleshooting 5 Place the clean HEPA filters back in the main unit making sure that it is firmly seated inside the unit 6 Place the tabs at the bottom of the grill plate into the base of the unit Gently push the grill plate back into place until you hear a click sound indicating that the grill is firmly latched DO NOT USE WATER OR ANY HOUSEHOLD CLEANERS OR DETERGENTS TO CLEAN THE HEPA...

Страница 8: ... Products This warranty is effective only if the product is purchased and operated in the country in which the product is purchased A product that requires modifications or adoption to enable it to operate in any other country than the country for which it was designed manufactured approved and or authorized or repair of products damaged by these modifications is not covered under this warranty TH...

Страница 9: ...nas inválidas y cuando el limpiador de aire se deje funcionando sin supervisión Desenchufe siempre el limpiador de aire cuando no lo esté usando No haga funcionar el limpiador de aire con un cable o un enchufe dañado o después de que limpiador de aire no funcione adecuadamente se haya caído o dañado de cualquier manera Deseche el filtro de aire o el retorno a SI Products Relaciones con el Consumid...

Страница 10: ...aciones técnicas Características Sharper Image Tower Cleaner Professional Panel de control Unidad principal HEPA Filters Placa de la parrilla trasera Tensión de entrada 120V Frecuencia nominal 60 HZ Potencia 60 vatios Peso 12 5 lbs Nivel de Ruido 60 dB Unidad de altura 28 pulgadas ...

Страница 11: ...es de encender el limpiador de aire debe asegurarse de que los filtros se encuentre bien asegurado y que no se haya aflojado en el envío 1 Para revisar los filtros abra la rejilla trasera empujando suavemente hacia abajo la pestaña de liberación que se encuentra en la parte superior de esa rejilla 2 Abra hacia afuera la bandeja hasta que las pestañas de la base de la rejilla se deslicen fácilmente...

Страница 12: ...ir cleaner will start to operate on LOW speed Una vez encendido el purificador de aire presione el botón para aumentar la velocidad del ventilador a la configuración MED Presione el botón nuevamente para aumentar la velocidad del ventilador a la configuración HIGH alta Para disminuir la velocidad del ventilador presione el botón hasta llegar a la configuración deseada La configuración de la veloci...

Страница 13: ...otón REPLACE UV BULB para reiniciar el indicador hasta que emita un pitido Cómo cambiar la bombilla UV C 1 Abra y retire la rejilla trasera 2 Quite la parte superior del filtro HEPA 3 Use un destornillador para quitar dos tornillos y retire la tapa de la bombilla UV de metal 4 Sujete la lámpara de rayos UV y tire de ella desde el socket del foco 5 Reemplazarla por la radiación UV C bulbo e introdú...

Страница 14: ... HEPA cada 18 meses para mantener el rendimiento óptimo de su limpiador de aire Para comprar un filtro HEPA de repuesto diríjase a su distribuidor en donde compró su limpiador de aire o visite www homedics com Fig 8 Fig 9 Fig 10 Problema Posible causa Solución La unidad no funciona La unidad no está enchufada No hay corriente en la unidad Conecte la unidad Pulse el botón POWER a conectar la alimen...

Отзывы: