42
VL-Z700S-T
VL-Z800S-S/E-S/E-T/Z900H-S
VL-Z950S-S/E-A/E-S/E-T/E-W
Item
Adjustment method
1) Perform the adjustment of white balance repeatedly.
(7) Adjustment of white balance
•
Measurement terminal:
EE output
•
Address:
"0128" INDOOR_W/B R
"012A" INDOOR_W/B R
•
Measuring instrument:
Vector scope
•
Object:
Grey scale
•
Data changing range:
"0000" to "03FF"
1) Perform the color gain adjustment repeatedly.
Adjustment address
Red amplitude
1.75
±
0.05 time (burst ratio)
: "013A"
Blue amplitude
1.35
±
0.05 time (burst ratio)
: "013C"
Yellow amplitude
1.25
±
0.05 time (burst ratio)
: "07DE"
Red phase
106
°
±
1
°
: "0138"
Blue phase
358
°
±
2
°
: "0136"
Yellow phase
168
°
±
2
°
: "07DD"
(10) Adjustment of auto white balance
adjustment
•
Measurement terminal:
EE output
•
Address:
"000C" OUTDOOR R
"000E" OURDOOR B
•
Measuring instrument:
Vector scope
•
Object:
Grey scale
•
Data changing range:
"0000" to "03FF"
1) Set the color temperature conversion filter (LB165) on the lens.
2) While shooting the gray scale normally, observe the monitoring screen of the vector
scope. By rewriting the data, position the luminescent spot so that the following burst
ratio is obtained.
R-Y 0
±
5% (burst ratio)
B-Y 0
±
5% (burst ratio)
(11) Adjustment of outdoor white gain
•
Measurement terminal:–
•
Address: 0001
•
Measuring instrument:–
•
Object: White pattern
•
Data changing range:–
(9) Adjustment of color gain
•
Measurement terminal:
EE output
•
Address:
"013A" CGIN RYG
"013C" CGIN BYG
"0138" CMAT RYG
"0136" CMAT BYG
"07DE" Yellow amplitude
"07DD" Yellow phase
•
Measuring instrument:
Vector scope
•
Object:
Waveform monitor color bar chart
•
Data changing range:
"0000" to "00FF"
1) This adjustment is performed automatically by writing data "05" at address "001" in the
signal system adjustment mode.
When the adjustment is completed normally, data "FF" is returned to address "001".
If data other than "FF" is returned, the adjustment has not been performed properly.
1) Set the color temperature conversion filter (LB165) on the lens.
2) This adjustment is performed automatically by writing data "06" at address "001" in
the signal system adjustment mode.
When the adjustment is completed normally, data "FF" is returned to address "001".
If data other than "FF" is returned, the adjustment has not been performed properly.
(8) Adjustment of indoor white gain
•
Measurement terminal:–
•
Address: 0001
•
Measuring instrument:–
•
Object: White pattern
•
Data changing range:–