4. Defect display
No.
Status
Buzzer
LED
Display
Content
Correspondance
method
-
No defects None None -- --
None
-- --
1
F-thermistor system defect
E.01
Defect of each thermistor, short circuit/wire breakage of
thermistor wiring and defect of main PWB
→
[1]
2
R-thermistor system defect
E.02
→
[2]
3
DEF-thermistor system defect
E.03
→
[3]
4
Outside temperature-thermistor
system defect
E.04
→
[4]
5
ICE-thermistor system defect
E.05
→
[5]
6
Defrost defect
7
Cooling fan motor system defect
E.07
E.08
Wire breakage of Thermo. fuse, def. heater, defect of main
PWB
(120-minute defrosting has been occurred continuously 2
times within the past 48 hours.)
→
[6]
8
R room fan motor system defect
E.10
Defect of wiring / main PWB
(When fan motor is ON, over current or no current is
detected.)
→
[8]
→
[7]
9
Plasmacluster system defect
E.11
Defect of wiring / main PWB
(When Plasmacluster is ON, over current or no current is
detected.)
→
[9]
10 Operation PWB communication defect
E.12
Defect of wiring , Operation or main PWB
(Communication with Operation PWB has been abnormal
over 5 times within the past 48 hours.)
→
[10]
11 Touch IC communication defect
E.13
Defect of touch sheet conector, Operation PWB
(Communication with Touch PWB has been abnormal over
2 times with in the past 48 hours)
→
[11]
15 F-thermistor system defect history
H.61
Defect of thermistor system has been occurred over 1
minute continuously within the past 48 hours
Defect of fan motor has been occurred over 3 times
continuously within the past 48 hours
→
[1]
16 R-thermistor system defect history
H.62
→
[2]
17 DEF-thermistor system defect history
H.63
→
[3]
19 ICE-thermistor system defect history
H.65
→
[5]
20 Cooling fan motor system defect history
H.67
→
[7]
21 R room fan motor system defect history
H.68
→
[8]
12 Auto ICE Maker system defect
E.15
Defect of wiring , ICE Maker , main PWB
(It is not defect)
(It is not defect)
→
[12]
13 Ice storage box is full
C.51
None
None
→
[13]
14 Water tank is out of water
C.52
→
[14]
18 Outside temperature-thermistor system
defect history
H.64
→
[4]
22 Plasmacluster system defect history
H.73
Defect of Plasmacluster system has been occurred over 3
times continuously within the past 48 hours.
→
[9]
23 ICE cooling insufficient history
H.74
→
[5]
24 F-room high temperature history
H.75
Temperature of F-thermistor has been reached over -10°C
continuously for 6 hours or more within the past 48 hours.
Temperature of ICE-thermistor has been reached over
-6°C continuously for 6 hours or more within the past
48 hours.
→
[1]
25 R-room high temperature history
H.76
Temperature of R-thermistor has been reached over +10°C
continuously for 6 hours or more within the past 48 hours
→
[2]
Defect of operation PWB.
Defect of each thermistor, short circuit/wire breakage of
thermistor wiring and defect of main PWB
Buzzer : = 0.5sec. ON/ 0.5sec. OFF, = 2sec. ON/ 0.5sec. OFF