SJFS810VWH
19
[10] SELF-DIAGNOSIS MODE
1. Entering method of the mode
1) Press the [Select] key on the control panel over 5 seconds at the opening condition of the refrigerating room
doors and the freezing room doors.
2) With a beep sound of buzzer, the self-diagnosis mode is entered. When the self-diagnosis mode is not entered
by the above operation, defect of Door SW system can be considered.
Select key
2. When the self-diagnosis mode is entered, the following movements will be made. Forced
release operation is not prepared for the self-diagnosis mode. It returns to the normal movement
after a lapse of 2 minutes.
•
Plasmacluster will not release the mode, and ON is forced for 2 minutes whether it is ON or OFF.
•
When the self-diagnosis mode is entered, beep sound for Door alarm must not be sounded for 20 minutes.
•
Defect and various conditions are shown by the beeping buzzer pattern.
•
Defect and various conditions are displayed on the Control panel. In case of plural defects and various conditions,
these are displayed one after another by button operation and all contents are notified.
3. Display of self-diagnosis
•
Display example of control panel (at the defect of F-thermistor system)
Results of diagnosis
Move to the next display.
Move to the previous display.
•
Buzzer notice example; (at fan motor system defect, 2 and 0.5 second ON)
ON
OFF
3 seconds stop
Repeating
3 seconds stop
0.5 second
0.5 second
Buzzer
Содержание SJ-FS810V-WH