OPERATION

DESCRIPTION OF OPERATING SEQUENCE

The following is a description of component functions during
oven operation.

OFF CONDITION

Closing the door activates the door sensing switch and
secondary interlock switches (1), (2). (In this condition, the
monitor switches (1) & (2) contacts are opened.) When the
oven is plugged in, and the rated voltage is supplied to the
control unit, (figure O-1), the display will show "   .   ".

IDLE CONDITION

When the door is opened, the contacts of the door sensing
switch open, initiating the following:
1. A signal is input to the control unit energizing the coil of

shut-off relay (RY-1).

2. The shut-off relay (RY-1) contacts close completing

circuits to turn on the oven lamp, blower motor and stirrer
motors.

3. If the door remains open, 60 seconds later the control

unit de-energizes shut-off relay (RY-1) turning off the
oven lamp, blower motor and stirrer motors.

When the door is closed, the door sensing switch contacts
close. With the closing of the door sensing switch contacts,
an additional circuit is provided which will permit the opera-
tion of the oven when one of the touch pads is depressed.
Since the control is enabled through the door sensing
switch, the door must be closed before the touch pads will
be effective. When the door is closed, a full 60 second IDLE
condition is always provided for selecting and pressing the
desired touch pads. A 60 second IDLE condition will also
follow the end of each cook cycle.

COOKING CONDITION

When the door is closed from the open position and Memory
pad is touched the, following will occur:

1. The contacts of relays are closed and components

connected to the relays are turned on (For details, refer
to Figure O-3)

2. Rated voltage is supplied to the primary winding of the

power transformer and is converted to about 3.4 volts
output on the filament winding, and approximately 2030
volts on the high voltage winding.

3. The filament winding voltage heats the magnetron

filament and the H.V. winding voltage is sent to a voltage
doubler circuit.

4. The microwave energy produced by the magnetron is

channelled through the waveguide into the cavity feed-
box, and then into the cavity where the food is placed to
be cooked.

5. Upon completion of the cooking time,  the oven will revert

to the IDLE condition.

6. When the door is opened during a cook cycle, monitor

switches (1) & (2), door sensing switch, secondary
interlock switches (1), (2) and primary interlock relays

(1), (2) are activated with the following results. The
circuits to the high voltage components are de-energized,
and the digital read-out displays "  .  " and  cooking is
cancelled (in the case of Memory cooking).

7. The monitor switch (1) is electrically monitoring the

operation of the secondary interlock switch (1) and
primary interlock relay (1), and monitor switch (2) is
electrically monitoring the operation of the secondary
interlock switch (2) and primary interlock relay (2), and
monitor switches (1), (2) are mechanically associated
with the door so that it will function in the following
sequence.

(1) When the door opens from a closed position, the contacts

of the primary interlock relays (1), (2) and secondary
interlock switches (1), (2) open.  Then the monitor switch
contacts close.

(2) When the door is closed from the open position, the

monitor switches (1), (2) contacts first open, and then the
contacts of the secondary interlock switches (1), (2)
close.

If the secondary interlock switches (1), (2) and primary interlock
relays (1), (2) fail with their contacts closed when the door is
opened, the closing of the monitor switches (1), (2) contacts will
form a short circuit through the monitor fuse, secondary inter-
lock switches (1), (2) and primary interlock relays (1), (2),
causing the monitor fuse to blow.

VARIABLE POWER COOKING FOR R22GT-F

Note: R-22VG-F has only 100% power level.

When Variable Cooking Power is programmed, the rated
voltage A.C. is supplied to the power transformer intermittently
through the contacts of relay (RY-2, RY-3). Relays RY-2 and
RY-3 are operated by the control unit within an interval second
time base. Microwave power operation is as follows:

POWER LEVEL

ON TIME

OFF TIME

100%

32 sec.

0 sec.

90%

30 sec.

2 sec.

80 %

26 sec.

6 sec.

70%

24 sec.

8 sec.

60%

22 sec.

10 sec.

50%

18 sec.

14 sec.

 40%

16 sec.

16 sec.

30%

12 sec.

20 sec.

20%

 8 sec.

24 sec.

10%

 6 sec.

26 sec.

0%

 0 sec.

32 sec.

Note:

The ON/OFF time ratio does not exactly correspond
with the percentage of microwave power, because
approx. 2 seconds are needed for heating of the
magnetron filament.

Содержание R-22GT-F

Страница 1: ...AVE ENERGY INSIDE FRONT COVER BEFORE SERVICING INSIDE FRONT COVER WARNING TO SERVICE PERSONEL 1 MICROWAVE MEASUREMENT PROCEDURE 2 FOREWORD 3 PRODUCT SPECIFICATIONS 4 GENERAL INFORMATION 4 OPERATION 6 TROUBLE SHOOTING GUIDE TEST PROCEDURE 10 TOUCH CONTROL PANEL 20 COMPONENT REPLACEMENT AND ADJUSTMENT PROCEDURE 30 PICTORIAL DIAGRAM 37 CONTROL PANEL CIRCUIT 38 PRINTED WIRING BOARD 39 PARTS LIST 40 PA...

Страница 2: ...nd transmission systems shall be repaired replaced or adjusted by procedures described in this manual before the oven is released to the owner e A microwave leakage check to verify compliance with the Federal Performance Standard should be performed on each oven prior to release to the owner BEFORE SERVICING Before servicing an operative unit perform a microwave emission check as per the Microwave...

Страница 3: ...voltage capacitors 4 Disconnect the leads to the primary of the power transformer 5 Ensure that the leads remain isolated from other components and oven chassis by using insulation tape 6 After that procedure reconnect the power supply cord When the testing is completed 1 Disconnect the power supply cord and then remove outer case 2 Open the door and block it open 3 Discharge two high voltage capa...

Страница 4: ...avity The water container shall be a low form of 600 ml 20 oz beaker with an inside diameter of approx 8 5 cm 3 1 2 in and made of an electrically nonconductive material such as glass or plastic The placing of this standard load in the oven is important not only to protect the oven but also to insure that any leakage is measured accurately 4 Set the cooking control on Full Power Cooking Mode 5 Clo...

Страница 5: ... packing is not damaged D The door is not deformed or warped E There is no other visible damage with the oven Servicing and repair work must be carried out only by trained service personnel DANGER Certain initial parts are intentionally not grounded and present a risk of electrical shock only during servicing Service personnel Do not contact the following parts while the appliance is energized Hig...

Страница 6: ...e must be grounded In the event of an electrical short circuit grounding reduces the risk of electric shock by providing an escape wire for the electric current This appliance is equipped with a cord having a grounding wire with a grounding plug The plug must be plugged into an outlet that is properly installed and grounded WARNING Improper use of the grounding plug can result in a risk of electri...

Страница 7: ...ming 21 SELECTATIME pad 22 STOP CLEAR pad touch to stop operation of oven and clear remaining heating time 23 SELECTAPOWER pad for setting variable power level 24 START pad touch to operate oven after door is closed and time is set 25 SET pad for setting memory 26 CHECK pad for checking memory 27 SIGNAL pad for setting signal sound 4 1 5 2 9 3 6 7 8 10 11 12 15 14 13 16 17 DOUBLE QUANTITY EXPRESS ...

Страница 8: ...to the cavity feed box and then into the cavity where the food is placed to be cooked 5 Upon completion of the cooking time the oven will revert to the IDLE condition 6 When the door is opened during a cook cycle monitor switches 1 2 door sensing switch secondary interlock switches 1 2 and primary interlock relays 1 2 are activated with the following results The circuits to the high voltage compon...

Страница 9: ...APPEARS ON DISPLAY COMMERCIAL FREQUENCY 60HZ POWER OUTPUT BY MAGNETRON 1 POWER OUTPUT BY MAGNETRON 2 OPERATION OF MAGNETRON SECONDARY INTERLOCK SWITCHES DOOR SENSING SWITCHES POWER TRANSFORMER 1 POWER TRANSFORMER 2 CAPACITOR 1 AC 2100V AC 2100V CAPACITOR 2 BLU BLU BLK WHT A1 RY 1 RY 3 RY 2 A7 A7 A3 GRN B2 B1 H3 H1 B3 RED RED RED RED RED BRN BRN WHT WHT WHT WHT WHT WHT WHT WHT H V RECTIFIER 1 H V R...

Страница 10: ...AGNETRON THERMISTOR OVEN THERMISTOR BLK BLK BLK BLK BLK BLK YEL TAB1 TAB2 PRIMARY INTERLOCK RELAY 1 FUSE MONITOR SWITCHES MAG NETRON TEMP FUSE 2 OVEN TEMP FUSE MAG NETRON TEMP FUSE 1 20A NOISE FILTER 120V 60 Hz PRIMARY INTERLOCK RELAY 2 AC 2100V AC 2100V RY 1 RY 3 RY 2 SECONDARY INTERLOCK SWITCHES DOOR SENSING SWITCHES POWER TRANSFORMER 1 POWER TRANSFORMER 2 CAPACITOR 1 CAPACITOR 2 BLU BLU BLK WHT...

Страница 11: ...are open 1 When the door is opened the contact of the door sensing switch and secondary interlock switches 1 2 are opened first then the contact of the monitor switches 1 2 are closed 2 As the door goes to a closed position the contacts of the monitor switches 1 2 are opened first then the contacts of the door sensing switch and the secondary interlock switches 1 2 close 3 If the door is opened an...

Страница 12: ...the all leads removed from components during testing 5 Reinstall the outer case cabinet 6 Reconnect the power supply cord after the outer case is installed 7 Run the oven and check all functions OVEN THERMISTOR The thermistor is a negative temperature coefficient type The temperature in the exhaust duct is detected through the resistance of the thermistor If the temperature is high the control pan...

Страница 13: ...ced in oven load food Variable cooking does not operates properly except HIGH power functions EE1 Magnetron 1 failure EE2 Magnetron 2 failure EE3 Magnetron 1 and 2 failure EE6 Oven thermistor failure EE7 Exhaust air temperature is too high EE8 Relay melt short EE9 Maximum time is exceeded EE16 Magnetron thermistor is open EE17 Magnetron temperature is too high PROBLEM POSSIBLE CAUSE AND DEFECTIVE ...

Страница 14: ... SHOULD BE OBSERVED Power output of the magnetron can be measured by performing a water temperature rise test This test should only be used if above tests do not indicate a faulty magnetron and there is no defect in the following components or wiring silicon rectifier high voltage capacitor and power transformer This test will require a 16 ounce 453cc measuring cup and an accurate mercury thermome...

Страница 15: ... Disconnect input leads and check for a short or open between the terminals using an ohmmeter Checking with a high ohm scale if the high voltage capacitor is normal the meter will indicate continuity for a short time and should indicate an open circuit once the capacitor is charged If the above is not the case check the capacitor with an ohmmeter to see if it is shorted between either of the termi...

Страница 16: ... during testing 6 Reinstall the outer case cabinet 7 Reconnect the power supply cord after the outer case is installed 8 Run the oven and check all functions NOTE If the door sensing switch contacts fail in the open position and the door is closed the blower motor stirrer motors and oven light will be activated by RY1 PRIMARY INTERLOCK RELAY RY2 RY3 1 Disconnect the power supply cord and then remo...

Страница 17: ... 2 Failure Test magnetron 1 2 Check blower fan motor and ventilation opening Magnetron 2 Failure Test magnetron 2 and Blower fan motor Food has been burned in oven Temperature of oven inside is very high Oven temperature fuse Magnetrontempera ture fuse 2 Magnetron tem perature fuse 1 150 C 120 C Non resetable type EE1 EE3 EE2 Oven shut off Non resetable type Open Close Display or temperature tempe...

Страница 18: ... number pad two figures or more are displayed c When touching the pads sometimes a pad produces no signal If the Key unit is defective 1 Disconnect the power supply cord and then remove outer case 2 Open the door and block it open 3 Discharge two high voltage capacitors 4 Replace the Key unit 5 Reconnect all leads removed from components during testing 6 Re install the outer case cabinet 7 Reconne...

Страница 19: ...ock it open 3 Discharge two high voltage capacitors 4 If the display fails to clear when the STOP CLEAR pad is depressed first verify the flat ribbon cable is making good contact verify that the door sensing switch stop switch operates properly that is the contacts are closed when the door is closed and open when the door is open If the door sensing switch stop switch is good disconnect the flat r...

Страница 20: ...V D C Power transformer 2 8 Disconnect the power supply cord and then remove outer case 9 Open the door and block it open 10 Discharge two high voltage capacitors 11 Reconnect all leads removed from components during testing 12 Re install the outer case cabinet 13 Reconnect the power supply cord after the outer case is installed 14 Run the oven and check all function N RELAY TEST To protect the el...

Страница 21: ...ated from other components and oven chassis by using insulation tape 6 After that procedure re connect the power supply cord 7 Follow the troubleshooting guide given below for repair STEPS OCCURRENCE CAUSE OR CORRECTION 1 The rated AC voltage is not present to power Check supply voltage and oven power cord terminal of CPU connector CN A 2 The rated AC voltage is present at primary Low voltage tran...

Страница 22: ...tecting Circuit This is a circuit for transmitting output change of thermistor Oven thermistor 1 to IC1 14 Magnetron Temperature Circuit Detect no load This is a circuit for transmitting output change of thermistor Magnetron thermistor to IC1 15 High Voltage Monitoring Circuit This circuit detects problems in the magnetron high voltage circuit by sensing a variation in the current flowing through ...

Страница 23: ...K THERMISTOR By inputting DC voltage corresponding to the temperature detected by the thermistor this input is converted into temperature by the A D converter built into the LSI 13 14 P55 P54 OUT Magnetron high voltage circuit driving signal To turn on and off the cook relay In 100 power level operation H level during cooking L level otherwise In other power level operation 90 80 70 60 50 40 30 20...

Страница 24: ...1 XOUT OUT Internal clock oscillation frequency control output Output to control oscillation input of XIN 32 VSS IN Connected to GND 33 P27 IN Signal coming from touch key When either one of G 12 line keys on key matrix is touched a corresponding signal out of P30 P31 P32 P33 P34 will be input into P27 When no key is touched the signal is held at L level 34 P26 IN Signal similar to P27 When either...

Страница 25: ... G4 line keys on key matrix is touched 61 P33 OUT Key strobe signal Signal applied to touch key section A pulse signal is input to P27 P26 P25 and P24 terminals while one of G5 line keys on key matrix is touched 62 P32 OUT Key strobe signal Signal applied to touch key section A pulse signal is input to P27 P26 P25 and P24 terminals while one of G6 line keys on key matrix is touched 63 P31 OUT Key ...

Страница 26: ...y resistor s with resistance equal to that of the controls are used 2 Servicing the touch control panel with power supply from an external power source Disconnect the touch control panel completely from the oven proper and short both ends of the door sensing switch on PWB of the touch control panel which activates an operational state that is equivalent to the oven door being closed Connect an ext...

Страница 27: ...mes Ex 345678 times Flashing 0 1sec BUZZER PAD DISPLAY INDICATOR TONE Door close CHECK CHECK No CHECK 82 68 CHECK user total count SIGNAL SIGNAL DOUBLE 34 56 QUANTITY service total count upper figure 3456XX 1 No 1 1 No after 1 sec 34 56 service total count upper figure 2 No 2 2 No after 1 sec 78 service total count lower figure CHECK 2 Practice for checking total operation time Ex 4567 hours Flash...

Страница 28: ... each stage 1 1 After 10 of total cooking time is passed 9 9 After 90 of total cooking time is passed START A There is no pause OTHER SETTING AND CHECKING PROCEDURE 1 EXPRESS DEFROST T STG1 STG 2 STG3 STG A x T B 1 To set the constants of Express defrost Ex 0 20T 20 40 at 1st stage 0 13T 30 30 at 2nd stage 0 67T 50 20 at 3rd stage Flicker 0 1 sec BUZZER PAD ORDER DISPLAY TONE Door close SET SET NO...

Страница 29: ... CHECK 0633 indicators ON plug off BLANK NOTE 1 This procedure must be performed within 1 minute 2 When IC2 malfunctions the unit does not function normally correct cooking data is not output data is not stored correctly in memory etc 3 Initialization of memory after repairing the touch control panel After repairing the touch control panel reset all counters to 0 including service counter Make sur...

Страница 30: ...nstall the outer case when operate the unit JUDGMENT PROCEDURE 1 PREPARATION FOR JUDGMENT 1 Disconnect the plug from the outlet 2 Remove the air filter and unscrew two screws at the control panel lower holding the control panel 3 Push up the control panel and pull it toward 2 JUDGMENT PROCEDURE FOR UPPER MAGNETRON AND ITS CIRCUIT Disconnect the power supply cord Disconnect lead wires to the interl...

Страница 31: ... the water increased 1 Yes EE1 should be indicated Lower magnetron its driving circuit and parts on the circuit are normal 1 CHECK OF TEMPERATURE RISE Fill approx 453 CC of water in a measuring cup and place it in the oven Operate the oven for one minute Substract cold water temperature from hot water temperature The result should be approx 18 36F 10 20 deg C If EE2 is indicated carry out Test pro...

Страница 32: ...transformer WARNING FOR WIRING 1 Disconnect the power supply cord 2 Make sure that a definite click can be heard when the microwave oven door is unlatched Hold the door in a closed position with one hand then pull the door release lever with the other this causes the latch leads to rise it is then possible to hear a click as the door switches operate 3 Visually check the door and cavity face plate...

Страница 33: ... remove outer case and rear cabinet referring to OUTER CASE REAR CABINET AND POWER SUPPLY CORD REMOVAL 2 Open the oven door and block it open 3 Discharge two high voltage capacitors 4 Remove the upper magnetron from the upper waveguide flange referring to MAGNETRON 1 AND OR 2 REMOVAL 5 Now the upper magnetron with the magnetron thermistor should be free 6 Remove the thermistor angle from the upper...

Страница 34: ...free CAUTION 1 DISCHARGE THE TWO HIGH VOLTAGE CAPACITOR BEFORE TOUCHING ANY OVEN COMPONENTS OR WIRING 2 DO NOT REPLACE ONLY THE HIGH VOLTAGE RECTIFIER IF IT IS DEFECTIVE REPLACE THE HIGH VOLTAGE RECTIFIER ASSEMBLY 3 WHEN REPLACING THE HIGH VOLTAGE RECTIFIER ASSEMBLY AND THE HIGH VOLTAGE CAPACITOR THE GROUND SIDE TERMINAL OF THE HIGH VOLTAGE RECTIFIER MUST BE SECURED FIRMLY WITH A GROUNDING SCREW 1...

Страница 35: ...el Fig 2 TO AVOID DAMAGE TO TOUCH CONTROL PANEL COVER THE TIP OF SCREWDRIVER WITH TAPE CONTROL PANEL ASSEMBLY AND CONTROL UNIT REMOVAL Replacement of individual component is as follows CONTROL UNIT AND CONTROL PANEL FRAME WITH KEY 7 Remove one 1 screw holding the decoration metal fittings to the control panel mounting angle 8 Remove two 2 screws holding the control panel mounting angle to the pane...

Страница 36: ...re and Adjustment procedure 1 Disconnect the power supply cord and then remove outer case referring to OUTER CASE REAR CABINET AND POWER SUPPLY CORD REMOVAL 2 Open the oven door and block it open 3 Discharge two high voltage capacitors If the door sensing switch secondary interlock switches 1 2 and monitor switches 1 2 do not operate properly due to a misadjustment the following adjustment should ...

Страница 37: ...ame assembly 3 Tighten the upper and lower oven hinge screws DOOR REPLACEMENT After adjustment make sure of the following 1 Door latch heads smoothly catch the latch hook through the latch holes and the latch head goes through the center of the latch hole 2 Deviation of the door alignment from horizontal line of cavity face plate is to be less than 1 0mm 3 The door is positioned with its face depr...

Страница 38: ... the three 3 screws holding the joint plate to the door panel 9 Release the latch spring from the tab of the joint lever and joint plate 10 Release the latch heads from joint lever and joint plate 11 Now the latch heads are free DOOR CASE REMOVAL 1 Remove the door assembly from oven cavity referring to DOOR REMOVAL 2 Remove choke cover from door panel referring to CHOKE COVER REMOVAL 3 Remove door...

Страница 39: ...K B L K B L K HIGH VOLTAGE CAPACITOR HIGH VOLTAGE CAPACITOR H V RECTIFIER H V RECTIFIER MAGNETRON LOWER MAGNETRON UPPER POWER TRANSFORMER POWER TRANSFORMER WHT WHT WHT WHT WHT BLK BLK STIRRER MOTOR LOWER WHT BLK GRN POWER SUPPLY CORD 120V 60Hz WHT WHT BLOWER MOTOR NOISE FILTER AND FUSE MAGNETRON TEMP FUSE 1 150 C OVEN TEMP FUSE 120 C WHT YLW BLU BLK BLK WHT WHT STIRRER MOTOR UPPER WHT WHT BLU WHT ...

Страница 40: ...C63 C62 100k TEST VCC SCL SDA A0 A1 A2 VSS 1 4 8 5 VCC VEE AVSS VREF AN7 AN6 AN5 AN4 AN3 AN2 AN1 AN0 P55 P54 P53 P52 P51 P50 P47 P46 P45 P44 P43 P42 INT1 INT0 RESET P71 P70 XIN XOUT VSS 1 5 15 10 20 25 30 33 P30 P31 P32 P33 P34 P35 P36 P37 P00 P01 P02 P03 P04 P05 P06 P07 P10 P11 P12 P13 P14 P15 P16 P17 P20 P21 P22 P23 P24 P25 P26 P27 32 35 40 45 50 55 60 64 IC1 IZA633DR CF1 CST4 00MGW R80 4 7k R81...

Страница 41: ...ST VCC SCL SDA A0 A1 A2 VSS 1 4 8 5 VCC VEE AVSS VREF AN7 AN6 AN5 AN4 AN3 AN2 AN1 AN0 P55 P54 P53 P52 P51 P50 P47 P46 P45 P44 P43 P42 INT1 INT0 RESET P71 P70 XIN XOUT VSS 1 5 15 10 20 25 30 33 P30 P31 P32 P33 P34 P35 P36 P37 P00 P01 P02 P03 P04 P05 P06 P07 P10 P11 P12 P13 P14 P15 P16 P17 P20 P21 P22 P23 P24 P25 P26 P27 32 35 40 45 50 55 60 64 IC1 IZA633DR CF1 CST4 00MGW R80 4 7k R81 4 7k R82 4 7k ...

Страница 42: ...CRO 1 RY2 B E Q3 C1 ZD1 R2 R101 R70 R1 Q1 Q23 D22 SP1 R40 10 E B E B D21 D101 C10 J9 R102 Q22 C3 CN B 1 3 1 3 CN H R64 9 R63 C63 C62 C4 J6 1 C8 C64 R62 64 60 R84 C60 R60 D70 D23 R4 8 C70 C101 R71 R61 C61 J5 R65 12 1 CN G CN D R66 5 4 IC3 7 J3 J4 6 1 8 9 16 1 3 2 15 Q2 E B R33 R32 R31 1 4 5 8 IC2 R30 Q60 E B CF1 C6 R3 C7 C5 C31 C30 R5 ZD2 3 20 25 33 F R83 C83 R82 C82 40 R81 C81 R80 C80 IC1 50 55 R5...

Страница 43: ...F 1 BD 2 7 FFPF A016WRK0 Vibration proof sheet 1 AU 2 8 TMAPCA772WRRZ Schematic diagram 1 AE CONTROL PANEL PARTS 3 1 DPWBFC507WRUZ Control unit R 22GV F 1 BN 3 1 DPWBFC452WRKZ Control unit R 22GT F 1 BN 3 1A QCNCMA308DRE0 4 pin connector CN A 1 AC 3 1B QCNCMA312DRE0 3 pin connector CN B 1 AB 3 1C QCNCMA039DRE0 3 pin connector CN H 1 AB 3 1D QCNCWA030DRE0 12 pin connector CN G 1 AE 3 1E QLUGPA012DR...

Страница 44: ... AH VRS1 RH VZA034DRE0 Varistor 10G471K 1 AD ZD2 VHEHZ4A2 1 Zener diode HZ4A2 1 AA 3 2 FPNLCB148WRK0 Control panel frame with key unit R 22GV F 1 AZ 3 2 FPNLCB468WRK0 Control panel frame with key unit R 22GT F 1 AZ 3 2 1 FUNTKA774WRE0 Key unit R 22GV F 1 AT 3 2 1 FUNTKA773WRE0 Key unit R 22GT F 1 AT 3 2 2 HDECAA195WRP0 Decoration metal fittings 1 AP 3 2 3 PCUSUA417WRP0 Cushion 1 AB 3 3 LANGTA243WR...

Страница 45: ...w 4mm x 8mm 9 AG 5 14 FANGKA200WRY0 Latch fixing angle 1 AQ 5 15 FLEVFA019WRY0 Joint lever 1 AP 5 16 LSTPCA002WRM0 Latch head 2 AM 5 17 MLEVPA220WRF0 Head lever 1 AM 5 18 MSPRCA097WRE0 Latch spring 1 AG 5 19 HBDGCA068WRE0 Door badge R 22GV F 1 AF 5 19 HBDGCA065WRE0 Door badge R 22GT F 1 AF 5 20 PCUSGA486WRP0 Handle cushion 1 AM MISCELLANEOUS 6 1 TINSEB105WRRZ Instruction manual 1 AG 6 2 TLABHA024W...

Страница 46: ...urned as indicated in the Service Policy REF NO PART NO DESCRIPTION Q TY CODE 7 14 LX BZA041WRE0 Specail screw 2 AA 7 15 XJPS740P10000 Screw 4mm x 10mm 2 AA 7 16 XOTWW40P08000 Screw 4mm x 8mm 29 AB 7 17 LX CZA095WREZ Special screw 3 AB 7 18 XOTS740P06000 Screw 4mm x 6mm 1 AA TOP PAD ASSEMBLY FPADBA313WRK0 WRAP COVER DOOR PROTECTION SHEET SPADPA552WRE0 PACKING CASE SPAKCE525WRE0 R 22GV F SPAKCE523W...

Страница 47: ... 4 19 4 8 4 9 1 9 4 9 4 5 4 6 1 11 1 11 1 11 4 7 4 10 4 4 7 16 4 25 4 27 4 42 7 16 4 13 7 16 7 12 7 4 7 11 7 4 7 12 7 12 7 2 7 3 7 4 7 12 7 16 7 5 7 4 7 10 7 12 7 15 7 4 7 4 4 26 7 16 7 16 x 2 7 16 2 2 2 2 1 5 1 6 7 12 7 15 6 8 6 14 7 17 7 17 4 12 7 2 7 8 7 6 7 6 4 1 7 13 7 18 4 17 4 21 1 14 7 12 1 6 4 33 4 32 7 14 4 13 7 16 7 6 1 15 1 15 1 3 4 40 1 7 1 3 4 28 6 10 4 29 A1 A2 B 1 10 4 38 4 2 6 6 7...

Страница 48: ...NEOUS DOOR PARTS CONTROL PANEL PARTS 3 6 3 4 3 5 3 3 3 2 1 3 2 2 3 2 3 1 3 2 3 6 15 Actual wire harness may be different from illustration 6 4 6 7 6 9 6 12 6 3 5 15 5 16 5 17 5 18 5 4 5 13 5 13 5 12 5 14 5 1 5 9 5 8 5 7 5 6 5 13 5 13 5 2 5 3 5 10 5 5 5 19 5 6 5 5 10 5 11 5 20 To high voltage capacitor To power transformer 6 5 ...

Отзывы: