Attachment precaution 1
VESA compliant Mounting bracket for display (M6 screw)
Rear cover of display
-Please take attention to following items for using screw holes behind IDP.
1) Please use more than 4 mounting screws to fix the display.
2) Please use symmetrical screw holes across the centre line.
*It can cause malfunction or deformation of the display to use screw holes asymmetrically.
3)Please use a mounting bracket having not more than 7.5mm hole diameter.
*Oversize of hole diameter can cause unfastening of the captive nut by the mounting screw.
4)Please use screws being correct length written in operation material of display.
*Over length of screw can cause unfastening of the captive nut by the mounting screw.
5)Please take measures by all means to prevent the screws loosening.
(For example : using screws with washer)
6) Please tighten screws hard with not more than 3N*m strength.
(Tightening torque: 3N*m )
VESA規格準拠取付ネジ孔
取付ネジ孔
固定用ネジ(M6)
取付金具
ディスプレイ
背面キャビネット
固定ボス
Hole diameter for mounting bracket
(not more than 7.5 mm)
Length of screw : 8mm-10mm
In case of PN-V601
VESA compliant screw holes
Screw holes
Screw (M6)
Captive nut for
fixing
Mounting
bracket
Rear cover of display