PN-V601 Installation Guidelines <Rev1.4 > September.30, 2010
CONFIDENTIAL
24
Securing space at rear-side
It is necessary to secure enough clearance for the intake of
the fan. If the space is small, there is a possibility that heat
will rise because upper the displays absorb the exhausted
heat from lower displays.
Please refer to “Precautions for temperature and clearance
space” (P3 – P7) to study details.
In addition, maintenance (cleaning / replacing of the fun) will
be done from the rear. Thus, securing space of 70cm at the
rear is recommended. In case of not being able to secure
the enough space at the rear, please make it possible to
move the display toward front easily for maintenance.
Please mount the displays to the stand after it is confirmed
that replacing fan cover is possible.
Precautions on stand installation
Concern about surrounding spaces
LCD
surface
Secure at
least
20cm
Installation example for stand installation
Secure
Clearance space
for the rear
Wall
Concern about securing stand
For safety, please give measures for preventing fall of monitors in case of
earthquake etc. - Secure firmly displays with wire or anchor etc.
Securing space at upper-side (above)
To release the heat, there must be space to exhaust air.
When taking off a display, the display must be lifted up, thus
please leave approx. 20cm apart at upper-side . Also, a
countermeasure for temperature at surface and lower area
should be considered referring “Precautions for temperature
and clearance space” (P3 – P7) .
Installation mode setting on
*OSD (portrait or landscape)
Please set installation orientation on OSD
OSD setting procedure: [Screen setting] – [installation]
Portrait mode: [portrait]
Landscape mode: [landscape] (Default setting)
* OSD – On Screen Display