42
E
Others
Function
Command Direction
Parameter
Reply
Control/Response contents
*
SCREEN SIZE
WIDE
WR
1-5
1-5 1: WIDE, 2: NORMAL, 3: Dot by Dot, 4: ZOOM1, 5: ZOOM2
○
VOLUME
VOLM
WR
0-31
0-31
MUTE AUDIO
MUTE
WR
0-1
0-1 0: OFF, 1: ON
-
INFORMATION
MODEL
INF1
R
Value
●
SERIAL NO
SRNO
R
Value
TEMPERATURE SENSOR
DSTA
R
0
Internal temperature normal
1 Internal temperature abnormal has occurred and the monitor is in standby mode
2 Internal temperature abnormal occurred (To delete the information of temperature
abnormal, turn off the main power.)
3
Internal temperature abnormal has occurred and backlight brightness is dimmed
4 Temperature sensor abnormal
TEMPERATURE ACQUISITION
ERRT
R
Value Returns the temperature at the temperature sensors.
Indicates a temperature sensor abnormality when “126” is returned.
CAUSE OF LAST STANDBY MODE
STCA
W
0
Initialization
R
0
No detectable error has occurred
1 Standby mode by POWER button or MONITOR OFF button
2
Main power off by the main power switch
3
Standby mode by RS-232C or LAN
4
Input signal waiting mode by No Signal
6
Standby mode by abnormal temperature
8
Standby mode by SCHEDULE setting
20 Standby mode by OFF IF NO OPERATION setting
LAN SETUP
DHCP CLIENT
DHCP
WR
0-1
0-1 0: OFF, 1: ON
* Apply the settings to this monitor by NTUP.
○
IP ADDRESS
IPAD
WR
XXXXXXXXXXXX XXXXXXXXXXXX
X: Only number is ok. If the number is less than 3 digits, to 3 digits to fill 0.
Example: 192168150001
* Apply the settings to this monitor by NTUP.
SUBNET MASK
SBMK
WR
XXXXXXXXXXXX XXXXXXXXXXXX
X: Only number is ok. If the number is less than 3 digits, to 3 digits to fill 0.
Example: 255255255000
* Apply the settings to this monitor by NTUP.
DEFAULT GATEWAY DFGW
WR
XXXXXXXXXXXX XXXXXXXXXXXX
X: Only number is ok. If the number is less than 3 digits, to 3 digits to fill 0.
Example: 000000000000
* Apply the settings to this monitor by NTUP.
FTP connection
FCHE
WR
0-1
0-1 0: OFF, 1:ON
Monitor name
MNTR
WR
XXXXXXXX
XXXXXXXX
XXXXXXXX
XXXXXXXX
16 characters or less; half-width alphanumeric characters, “-”, and “_”.
(The field can be left blank, but spaces cannot be entered.)
FTP Username
FUSR
WR
XXXXXXXX
XXXXXXXX
8 characters or less; half-width alphanumeric characters, “-”, and “_”.
(The field cannot be left blank, and spaces cannot be entered.)
FTP Password
FPAS
WR
XXXXXXXX
XXXXXXXX
8 characters or less; half-width alphanumeric characters, “-”, and “_”.
(The field cannot be left blank, and spaces cannot be entered.)
User name
USER
WR
XXXXXXXX
XXXXXXXX
8 characters or less; half-width alphanumeric characters, “-”, and “_”.
(The field can be left blank, but spaces cannot be entered.)
Password
PASS
WR
XXXXXXXX
XXXXXXXX
8 characters or less; half-width alphanumeric characters, “-”, and “_”.
(The field can be left blank, but spaces cannot be entered.)
Auto logout time
LOTM
WR
00000-65535
00000-65535 Set the time that display terminate a network connection automatically by minutes.
Data port
TCPP
WR
01025-65535
01025-65535
Set the TCP port number for data communication.
* Apply the settings to this monitor by NTUP.
Reflecting LAN setting
NTUP
W
1
1
Applies the DHCP CLIENT, IP ADDRESS, SUBNET MASK, DEFAULT GATEWAY,
and Data port settings to this monitor.
Controlling the Monitor with a computer (RS-232C)