MX-FN23 TROUBLE CODE 5 – 2
F1-19
Finisher paper alignment motor F
trouble
F1-20
Finisher paper alignment motor R
trouble
F1-29
Finisher cooling fan trouble
F1-37
Finisher RAM data trouble
F1-50
Finisher incompatible trouble
Phenomenon
Operation trouble of the paper alignment plate F
Case 1
Cause
Connection trouble or disconnection of the connector
and the harness of the motor
Check &
Remedy
Check the connection of the connector and the
harness in the motor line with the finisher control
PWB.
Connect the connector properly. Replace the
harness.
Case 2
Cause
Paper alignment plate home position sensor F
(FAPHPS-F) trouble.
Check &
Remedy
Check to confirm that the FAPHPS-F turns ON/OFF
with SIM3-2.
If it does not turn ON/OFF, check the connection of
the connector and the harness of the sensor.
Replace the sensor.
Case 3
Cause
Motor lock, an overcurrent to the motor, intrusion of
foreign material.
Check &
Remedy
Select the FPAM-F with SIM3-3 to check the
operation of the single unit.
Check to confirm that there is no foreign material in
the drive section and the alignment plate.
Case 4
Cause
Finisher control PWB trouble. Motor trouble
Check &
Remedy
Replace the finisher control PWB or the motor.
Phenomenon
Operation trouble of the paper alignment plate R
Case 1
Cause
Connection trouble or disconnection of the connector
and the harness of the motor
Check &
Remedy
Check the connection of the connector and the
harness in the motor line with the finisher control
PWB.
Connect the connector properly. Replace the
harness.
Case 2
Cause
Paper alignment plate home position sensor R
(FAPHPS-R) trouble.
Check &
Remedy
Check to confirm that the FAPHPS-R turns ON/OFF
with SIM3-2.
If it does not turn ON/OFF, check the connection of
the connector and the harness of the sensor.
Replace the sensor.
Case 3
Cause
Motor lock, an overcurrent to the motor, intrusion of
foreign material.
Check &
Remedy
Select the FPAM-R with SIM3-3 to check the
operation of the single unit.
Check to confirm that there is no foreign material in
the drive section and the alignment plate.
Case 4
Cause
Finisher control PWB trouble. Motor trouble
Check &
Remedy
Replace the finisher control PWB or the motor.
Phenomenon
When the finisher cooling fan is operating, the lock
signal is not canceled in a certain time.
Case 1
Cause
Improper connection or disconnection of the fan
connector and harness.
Check &
Remedy
Check the connector and harness of the finisher
control PWB and the fan line.
Connect the connector securely. Replace the
harness.
Case 2
Cause
Motor lock, an over current to the motor, intrusion of
a foreign material.
Check &
Remedy
Select the FCF with SIM03-03 and check the
operation of the single unit.
Case 3
Cause
Finisher control PWB trouble, fan trouble.
Check &
Remedy
Replace the finisher control PWB or the staple unit.
Phenomenon
Backup RAM operation trouble
Case 1
Cause
Finisher control PWB trouble. EEPROM trouble.
Check &
Remedy
Replace the finisher control PWB or the EEPROM.
Phenomenon
Connection of a finisher incompatible with the
machine is detected.
Case 1
Cause
Connection of a finisher incompatible with the
machine is detected.
Check &
Remedy
Connect the MX-FN23 to the machine.