AX1
100
(R)
11
–
3
(1) Push "START". PM starts.
10
TOTAL TEST
direct select key: [info]
RY-1, FM, PM
I. DAMPER: OPEN
how to operate at production
line
After 30 sec.
After 1min. judgment
power on
" 01" appears when Antenna is defect.
And test mode doesn't continue.
MICRO (0%)
MICRO (100%)
FM, COOK (OL)
PM
I. DAMPER: OPEN
[STOP/CLEAR]
[info]
Test mode doesn't continue.
[MICRO]
[MICRO]
[START]
[info]
(2) steam mode
Steam mode (high) works for 30 min.
RY-1, EH, PM, FM
I. DAMPER: CLOSE
detail of test
test name
No
output
example of display
*Check the engine thermistor works correctly. (open / short check)
*"CHECK" display appears after FLASH (2) min.
(3) Judgment
Judgment
OK
ETH is OK.
OK
NG
see next page
(4) Shortcut to the test mode 06
When OK display (1111) and "CHECK" display appears, test mode 06 starts
by pushing [START] key.
Before pushing [START] key, water tank should be removed. (Refer to test mode 06)
You don't have open the door.
The detail of judgment (test no. 10)
Display
Error timing
ETH
OTH
Antenna
Damper
01
During microwave mode
Not judged
Not judged
NG
Not judged
Antenna ERROR
0 11
After 18 sec from start
Not judged
Not judged
Not judged
NG
Damper ERROR
- -0
Right after starting
Not judged
Not judged
Not judged
NG
Damper ERROR
00 00
During steam heating mode
NG
Not judged
Engine thermistor is defect (short).
00 00
During steam heating mode
NG
Not judged
Engine thermistor is defect (open) or Engine heating element does
not work when error appears after 30 sec.
00 10
During microwave mode
Not judged
NG
Oven thermistor is defect (short)
00 10
During microwave mode
Not judged
NG
Oven thermistor is defect (open)
11 11
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK