AX1
100(R)
11
–
2
Water draining finishes for 60sec.. (max. working time is 7min.)
07
CONSUMPTION CHECK
direct select key: [STEAM-HIGH]
Output switches by key operation.
If no key operation continues for 60sec, output turns off.
[STEAM HIGH] key
*Engine heater mode with temperature control by ETH
[DUAL HIGH] key
*Top heater mode with temperature control at 250ºC.
*Microwave mode at 70%.
*EE01 is displayed when oven thermister is defect.
[GRILL] key
*Top heater mode with temperature control at 250ºC.
*EE01 is displayed when oven thermister is defect.
[MICRO] key
*Microwave mode at 100%.
Waiting condition
EH, RY-1(OL)
FM, PM
I. DAMPER: CLOSE
MICRO(100%)
RY-1, GH, FM
I. DAMPER: CLOSE
RY-1, GH, FM
I. DAMPER: CLOSE
Oven thermister error
MICRO(100%)
RY-1, FM
I. DAMPER: OPEN
08
Monitor mode
Monitor key, 60 times speed key and stage cancel key are available until power
turn off.
OFF
I. DAMPER : OPEN
detail of test
test name
N.o
output
example of display
RY-1, EH, FM
I. DAMPER: OPEN
OFF
I. DAMPER: OPEN
OFF
I. DAMPER: OPEN
Pump motor stop for 0 sec (Flash: EP_T6_TT) to delete water by engine heating.
*Flashing the right-side bar.
*Work end with alarm.
RY-1, EH, PM, FM
I. DAMPER: OPEN
06
Water drain
Pushing [START] key water draining works.
*To empty the water of the tank.
*After work for 60 sec. (FLASH: EP_MN_PO), the next stage start.
*Flashing the right-side bar.
If temperature adjustment (by ETH) acts or 6 minutes pass, the next stage starts.
*Temperature adjustment Flash: (EP_T6EH_H)
*Many a little amount of water is left to the Engine.
*Flashing the right-side bar.