Rev. 1
3
8
/
Tempe-
rature
(
°
C)
Humidity (%)
Sensor reading value
Sensor reading value
Register value
<5
5† <10
10† <15
15† <20
20† <25
25† <30
30† <35
35† <40
40†
<59(H)
16B(H)† <19E(H)
19E(H)† <1D1(H)
1D1(H)† <204(H)
204(H)† <236(H)
236(H)† <265(H)
265(H)† <290(H)
290(H)† <2B9(H)
2B9(H)†
<15
<1E(H)
15† <25
1E(H)† <33(H)
25† <35
33(H)† <47(H)
35† <45
47(H)† <5C(H)
45† <55
5C(H)† <70(H)
55† <65
70(H)† <85(H)
65† <75
85(H)† <99(H)
75† <85
99(H)† <AE(H)
85 †
AE(H)†
N/L1
N/L1
N/L2
N/N
H/H
H/H
H/H
H/H
H/H
N/L2
N/N
L/L
N/L1
H/L
H/L
Tempe-
rature
(
°
C)
Humidity (%)
Sensor reading value
Sensor reading value
Register value
<5
5† <10
10† <15
15† <20
20† <25
25† <30
30† <35
35† <40
40†
<59(H)
16B(H)† <19E(H)
19E(H)† <1D1(H)
1D1(H)† <204(H)
204(H)† <236(H)
236(H)† <265(H)
265(H)† <290(H)
290(H)† <2B9(H)
2B9(H)†
8
8
8
8
7
7
7
6
6
8
8
8
7
7
6
6
6
5
8
8
7
7
6
6
5
4
4
7
7
7
6
5
4
4
2
2
7
7
6
5
4
4
2
1
1
7
6
5
4
4
3
1
1
1
7
6
5
4
3
1
1
1
1
6
5
4
3
3
1
1
1
1
6
5
4
3
2
1
1
1
1
<15
<1E(H)
15† <25
1E(H)† <33(H)
25† <35
33(H)† <47(H)
35† <45
47(H)† <5C(H)
45† <55
5C(H)† <70(H)
55† <65
70(H)† <85(H)
65† <75
85(H)† <99(H)
75† <85
99(H)† <AE(H)
85 †
AE(H)†
H/H
H/H
H/H
H/H
2.6
Color Drift Correction
The
AR-C360P
comes with several ID units and LED heads, therefore, causes color drift. This mechanical
color drift can automatically be corrected with the following procedures.
(1)
Automatically Corrected Color Drift
1
X Axis Color Drift (position off-alignment due to LED head)
2
Skew Color Drift (position off-alignment due to LED head)
3
Y Axis Color Drift (I/D unit and position off-alignment due to LED head)
(2)
Correction Method
The color drift detection pattern set is printed on the belt. This is then read by the reflection
sensor to detect the color drift value of each color and therefore, determine the correction
level. The modification takes place by comparing the each colors’ (Cyan, Magenta and
Yellow) write timing with black, according to the correction value.
2.7
Image Transfer Control According to Environmental Change (Room Tempera-
ture and Relative Humidity)
The
AR-C360P
measures the room temperature with the room temperature sensor and measures the
relative humidity with the humidity sensor. It further computes the optimal transfer voltage under the
environmental conditions (temperature and RH) measured. Then printing is controlled in real-time at
this optimal voltage.
Environmental Detection Table
Содержание AR-C360P
Страница 2: ...Ver Date No Revision Page Changes In Charge Document Revision History ...
Страница 5: ...Rev 1 5 Do not go near an ejection area while the power is on and in printing You may get injured ...
Страница 9: ...Rev 1 9 ...
Страница 13: ...Rev 1 13 Finisher Unit AR C36TF 2 3 Hole Punch Unit AR C36HP No Image ...
Страница 16: ...Rev 1 16 ...
Страница 19: ...Rev 1 19 ...
Страница 40: ...Rev 1 40 ...
Страница 48: ...Rev 1 48 ...
Страница 51: ...Rev 1 51 4 2 Parts Layout Printer Unit 120V ...
Страница 52: ...Rev 1 52 Base Assy 1 2 A A ...
Страница 53: ...Rev 15 4 Base Assy 2 2 ...
Страница 54: ...Rev 1 55 Side R Assy ...
Страница 55: ...Rev 1 56 Side F Assy ...
Страница 56: ...Rev 1 56 Cover Assy OP Panel ...
Страница 57: ...Rev 1 57 FDR Unit Regist A A B B ...
Страница 58: ...Rev 1 58 FDR Unit MPT ...
Страница 59: ...Rev 1 59 Sensor Regist Assy ...
Страница 60: ...Rev 1 60 Eject Assy 2 ...
Страница 61: ...Rev 1 61 Plate Top Assy A A A A ...
Страница 62: ...Rev 1 62 Job Offset Assy ...
Страница 63: ...Rev 1 63 Basket Assy ...
Страница 64: ...Rev 1 64 Plate Shield Box Assy ...
Страница 65: ...Rev 1 65 Unit Duplex 1 2 8 ...
Страница 66: ...Rev 1 66 Unit Duplex 2 2 ...
Страница 87: ...Rev 1 87 Lever 1 4 3 20 Unit Duplex 1 Pull out Unit Duplex 1 while pressing the lever ...
Страница 89: ...2EV 89 ...
Страница 109: ...Rev 1 109 ...
Страница 161: ...Rev 1 161 Ground Charge roller Development roller Toner supply roller Development braid Figure 7 3 ...
Страница 169: ...Rev 1 169 8 2 Diagram of Part Layout of Various PCB ...